background image

Operation - Fan

PULL CHAIN OPERATING INSTRUCTIONS

PULL CHAIN OPERATING INSTRUCTIONS

Install the pull chain and fob (CC) onto the pull chain located in
the switch housing (JJJ). Turn on the power and check the 
operation of the fan.

The pull chain controls the fan speed as follows:
1 pull - High, 2 pulls - Medium, 3 pulls - Low, and 4 pulls - Off.

Speed settings for warm or cool weather depend on factors such
as the room size, ceiling height, and number of fans.

JJJ

CC

NOTE:

 

Wait for the fan to stop before reversing the direction 

of the blade rotation.

NOTE:

 

Not recommended to use misting feature with fan in 

reverse.

REVERSE SWITCH OPERATING INSTRUCTIONS

REVERSE SWITCH OPERATING INSTRUCTIONS

The reverse switch is located on the surface of the switch housing. 
This switch controls directions: forward (switch down) or reverse 
(switch up).

Warm weather - (Counterclockwise Direction) A downward air flow 
creates a cooling effect. This allows you to set your air conditioner 
on a higher setting without affecting your comfort.

Cool weather - (Clockwise Direction) An upward air flow moves 
warm air off the ceiling. This allows you to set your heating unit on 
a lower setting without affecting your comfort.

20

Содержание YG188M-NI

Страница 1: ...ning to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday call Hampton Bay Customer Service Item 1005 131 413 Model YG188M NI Visual instruction of how to install this fan Visit www hom...

Страница 2: ...s Safety Information Warranty Pre installation Specifications Tools Required Hardware Included Package Contents Installation Assembly Hanging the Fan Attaching the Fan Blades Safety Information Mistin...

Страница 3: ...dust cloth or lightly dampened cloth will be suitable for most cleaning 8 After making electrical connections spliced conductors should be turned upward and pushed carefully up into the outlet box Th...

Страница 4: ...s is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finish...

Страница 5: ...ting screw not to scale Pull chain and fob not to scale 7 Ft water tube not to scale 25 Ft water tube not to scale Two way connector not to scale Spigot hose connector not to scale Tube clip not to sc...

Страница 6: ...A B C D E Quantity Quantity 1 1 1 1 1 Description Description Mounting bracket preassembled Canopy Hanger ball downrod assembly Misting ring cover Misting ring C 12 in and 24 in longer downrods are a...

Страница 7: ...included directly to the building structure Use appropriate fasteners and materials not included The outlet box and its bracing must be able to fully support the weight of the moving fan at least 35...

Страница 8: ...y B from the mounting bracket A by turning the canopy B counterclockwise Remove the cotter pin NN and clevis pin OO and loosen the two collar setscrews PP from the motor collar Take out the setscrew Q...

Страница 9: ...wnrod bottom and collar then insert the clevis pin OO through all holes of the downrod and collar be careful not to jam any wires or tubes inside the downrod Restore the cotter pin NN to the end of th...

Страница 10: ...or assembly F up to the mounting bracket A and seat the hanger ball down rod assembly C in the mounting bracket A socket Make sure the tab on the mounting bracket A socket is properly seated in the gr...

Страница 11: ...the fan motor black wire and the blue wire to the supply black hot wire using a plastic wire nut AA Turn the wire nut connections upward spreading them apart so the green ground and white wires will b...

Страница 12: ...il it drops into place XX XX A B UU A B UU WW NOTE The canopy has two mounting orientations at 180 apart Select the orientation that points the tube in the direction best for routing to the pump Remov...

Страница 13: ...th the blade arm posts AAA and press the blade down firmly Ensure the key slot holes ZZ are properly seated on the blade arm posts AAA Firmly slide the blade G away from the blade arm H until the blad...

Страница 14: ...alancing the blades G or cleaning the fan Do no insert foreign objects between rotating fan blades G Fasten the blade assemblies to the fan motor assembly F by lining up the slots CCC of the motor F w...

Страница 15: ...bove the water spigot or reservoir 7 Pump must be installed at a vertical distance 8 ft from the fan 8 Tubing needs to be crimp free Nothing can be put on top of the tubing which can cause damage or p...

Страница 16: ...to ceiling with tube clips HH and tube clip mounting screws and anchors JJ and II If removal of the water lines from a two way connector is required for any reason depress the rings FFF While pulling...

Страница 17: ...ecure ring GGG from the hose connector GG and attach the 7 ft water tube EE into the faucet connector GG Reinstall the fixed secure ring GGG Attach the hose connector GG to the hose spigot HHH To sepa...

Страница 18: ...rings FFF on the bottom of the pump I and pull out the plastic plugs III Attach the 7 Ft water tube DD and 25 Ft water tube EE into the pump I To separate the water tubes DD and EE you MUST PUSH DOWN...

Страница 19: ...evice continued 15 Connecting the power cord Plug the power cord J into a 120v outlet Once you restore power to the house the misting device is ready to use J 19 HAMPTONBAY COM Please contact 1 855 HD...

Страница 20: ...reversing the direction of the blade rotation NOTE Not recommended to use misting feature with fan in reverse REVERSE SWITCH OPERATING INSTRUCTIONS REVERSE SWITCH OPERATING INSTRUCTIONS The reverse s...

Страница 21: ...ditions Using the misting feature in very high humidity will aid in cooling but water build up on surfaces below the fan is possible At a distance from the fan you may experience light droplets of wat...

Страница 22: ...OPERATION RESERVOIR DRAWN OPERATION If connecting to a hose spigot or plumbed water supply is not an option it is possible to use a water reservoir not included The reservoir needs to be clean free f...

Страница 23: ...stall the mist ring cover MMM being sure it aligns with the tabs PPP on the mist ring cover MMM and misting ring E If cleaning does not help replacement nozzles are available Call Customer Service 1 8...

Страница 24: ...ceiling to the canopy It should not touch the ceiling Make sure your ceiling box is secure and rubber isolator pads are used between the mounting bracket and outlet box The fan will not start The fan...

Страница 25: ...then select any fan blade and measure from the center of the selected blade to the point on the ceiling Rotate the fan until the next blade is positioned and repeat the measurement using the same poi...

Страница 26: ...astic wire nut Misting ring mounting screw Part Part CC DD EE FF GG HH II JJ KK LL NNN Description Description Pull chain and fob 7 Ft water tube 25 Ft water tube Two way connector Spigot hose connect...

Страница 27: ...HAMPTON HAMPTONBAY COM Retain this manual for future use Questions problems missing parts Before returning to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday call Hampton Bay Customer...

Отзывы: