HAMPTON BAY Hampton H25-NG Скачать руководство пользователя страница 39

Hampton H25 Direct Vent Freestanding Gas Stove

39

WARRANTY

Hampton Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each
unit thoroughly before it leaves our facility.  FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the  original
purchaser  of a Waterford Product. This warranty is not transferable.

The Warranty:  

Limited Lifetime

External casting, not directly in contact with the fire, such as hobs, sides, ash lips, legs, fronts and fire doors, are covered against cracks and warps resulting from
manufacturer defects, parts and subsidized labour* for three (3) years from the date of purchase and parts only thereafter.

The combustion chamber, heat exchanger, burner tubes/pans and logs are covered under the Limited Lifetime Warranty for five (5) years for parts and subsidized labour*
and parts only thereafter.

Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for five (5) years and parts only thereafter from date of purchase.

Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly
components, and gas valves are covered for one year parts and subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered
repairs and continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date
of replacement.

FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.

Simpson Dura-Vent venting components are covered by Simpson Dura-Vent Inc. warranty.

Conditions:

Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three
days of installation. Reported damage after this time will be subject to rejection.

Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent
provided that the defective part be returned to the distributor or agent 

Transportation Prepaid,

 if requested.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated
for manufacturer defect.

The authorized selling dealer is responsible for all in-field service work carried out on your Waterford product. FPI will not be liable for results or costs of workmanship
from unauthorized service persons or dealers.

At all times FPI reserves the right to inspect product in the field which is claimed to be defective.

All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer
name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint (charcoal units),  porcelain (including pinholes, scratches and minor shade mismatch), door or glass
gasketing or trim.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured.
ie. as products evolve, field modifications or upgrades will not be performed.

FPI will not be liable for travel costs for service work.

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the  terms of this warranty policy.

Embers, door and glass, gaskets, door handles, paint are not covered under the terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject  to misuse, improper installation, negligence
or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by
mechanical systems such as furnaces, fans, clothes dryer, etc.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from Waterford, may nullify
your warranty on this product.

Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.

* Subsidy according to job scale as predetermined by FPI.

Содержание Hampton H25-NG

Страница 1: ...What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Foll...

Страница 2: ...and crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model H25 has been approved by Warnock Hersey for both safety...

Страница 3: ...formation 6 Installation Checklist 6 Clearances to Combustibles 6 Locating Your Gas Stove 7 Manufactured Mobile Home Requirements 7 Combustion and Ventilation Air 7 Optional Fan Installation 7 Venting...

Страница 4: ...ton units are constantly being improved Checkthelabelontheunitandifthere isadifference thelabelontheunitisthecorrect one For the State of Massachusetts installation and repair must be done by a plumbe...

Страница 5: ...ured USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not converti ble for use with other...

Страница 6: ...onal Fan see page 7 3 Set vent restrictor page 9 4 Install venting Check all venting require ments pages 9 13 Vertical Termination with Co linear Flex System page 16 Hor izontal Termination Kits page...

Страница 7: ...N OPTIONAL FAN INSTALLATION Fan Kit Contains Qty Description 1 Fan Assembly c w green wire attached 1 Thermodisc 1 power cord 2 2 1 4 x 20 hex nut 1 Fan Speed Control 2 Remove the rear access panel on...

Страница 8: ...tove and secure with the 2 supplied bolts 2 1 4 20 hex head 12 Before re attaching the rear access panel the valve wires and the fan wires need to be connected Re connect the red and grey valve wires...

Страница 9: ...y Warnock Hersey These units use the balanced flue technol ogy Co Axial system The inner liner vents productsofcombustiontotheoutsidewhilethe outer pipe draws outside combustion air into the combustio...

Страница 10: ...p min 12 30cm with Riser Vent min 6 15cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent ou...

Страница 11: ...h 7 Black N A N A 4D7AB Adjustable Length 12 Galvinized N A N A 4D12A Adjustable Length 12 Black N A N A 4D12AB 45O Elbow Galvinized 945 4DT EL45 4D45L 45O Elbow Black 945B 4DT EL45B 4D45LB 45O Elbow...

Страница 12: ...onal Ltd Dura Vent and Direct Vent GS are registered and or proprietary trademarks of Simpson Dura Vent Co Inc ThisproducthasbeenevaluatedbyIntertekfor using a Dura Vent Flue Adaptor in conjunction wi...

Страница 13: ...he vent is ENCLOSED in a chase min size 9 x 9 maintain a 1 1 4 clearance to combustibles May be installed in Manufactured Mobile Homes after first sale Horizontal Terminations for All Venting Systems...

Страница 14: ...ipe length is 30 feet with min of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet w...

Страница 15: ...e note min 1 foot between 90o elbows is re quired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Withtheseoptions max total pipelengthis30feetwithmin of 6 feet tot...

Страница 16: ...ting Arrangements chart below for minimum and maximum flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contou...

Страница 17: ...e to length Attach the 45o elbow to the rigid pipe and ensure that the pipe length when cut with the 45o elbow will seat onto both the starter collar and the 90o elbow Crimped sec tionofrigidpipeseats...

Страница 18: ...fit of the liner onto the 4 dia starter collar 8 Cut the 4 dia flex liner to the desired size Hint leaveanextra12 to16 oflength this willmakethefinalassemblyeasiertowork with 9 Securethe4 dia flexline...

Страница 19: ...to the wall It is also important to notethewallthickness Beforecuttingthevent hole through the wall ensure that ALL vent and termination clearances see page 10 will be met If this is an outside corner...

Страница 20: ...pipe and nearby combustible surfaces is 1 1 4 inch Be sure to check the vent termination clearance require ments from decks windows soffits gas reg ulators air supply inlets and public walkways as sp...

Страница 21: ...equired Other parts may be re quired for your particular installa tion See above for a list of vent parts Ifinstallingterminationonasidingcoveredwall a vinyl siding standoff or furring strips can be u...

Страница 22: ...he Backing Plate into the wall pene tration heat shield and attach using 4 screws Dia 4 8 Connect all pipe sections to unit and install into wall a Measure pipe length required and cut to length Hint...

Страница 23: ...re sili cone to the out er pipe before connecting the inner pipe 4 Assemblethedesiredlengthsofblackpipe and elbows necessary to reach from the appliance adapter up though the Round Support Box Insure...

Страница 24: ...n place and sealed before installing a Direct Vent sys tem within the chimney If the appliance shuts off during opera tion contact a qualified service person to determine if a negative pressure and or...

Страница 25: ...rities and the CAN CGA B149 installation codes ForUSAinstallationsfollowlocalcodesand or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use onlyapprovedfittings Al...

Страница 26: ...authorized Hampton Installer at the time of installation or service 4 Light the pilot and turn the valve to ON position Read manometer 5 The pressure check should be carried out with the unit burning...

Страница 27: ...hold on to the elbow behind the orifice 9 Reinstall new burner orifice LP stamped 54 and tighten 10 Reverse steps 3 to 2 11 Attach the Conversion label This unit has been converted to Propane on top...

Страница 28: ...lly and refer to the dia grams If the logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot operation The gas log kit contains the following a Rear Log 9...

Страница 29: ...oto below 7 Place the center cross log on the locating pin in the top of the rear log and position as shown below Logs must be oriented as shown below 8 Test fire to ensure proper light off make sure...

Страница 30: ...n interior wall Hamptonoffersanoptionalprogrammablether mostat but any 250 750 millivolt rated non anticipator type thermostat that is CSA ULC or UL approved may be used 14 GA 16 GA 18 GA 20 GA 22 GA...

Страница 31: ...are away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock haz ard and should be plugged dire...

Страница 32: ...rocess Theglassshould be cleanedor the film will bake on and become very difficult to remove Use a non abrasive cleaner and NEVER clean the glass while it is hot 1 TurnstoveOFFusingtheBurner ON OFF sw...

Страница 33: ...Hampton H25 Direct Vent Freestanding Gas Stove 33 Copy of the Lighting Plate instructions OPERATING INSTRUCTIONS...

Страница 34: ...Body Firebox Different types and thicknesses of steel will expandandcontractatdifferentratesresulting in some cracking and ticking sounds will be heard throughout the cycling process WARNING CHILDREN...

Страница 35: ...ions orfittingshavebeendisturbed andconse quently loosened Also check mechanical supportssuchasWallStraps orplumbers tape for rigidity 5 Verify proper operation after servicing LOG REPLACEMENT Theunit...

Страница 36: ...alve assembly continue 14 Remove two 2 thermopile wires 15 Removethermocouplewitha9mm metric wrench 16 Remove pilot nut with an 11 mm wrench 17 Remove valve to orifice nut with a 13 16 wrench 18 Remov...

Страница 37: ...tion Part Description Part Description 50 W260260 Top Relief Frame Gasket 51 942 117 Top Relief Frame 52 W260280 Top Relief Plate Gasket 53 290 021 Top Relief Plate 54 Capscrew 1 4 x 1 3 4 NC 55 Side...

Страница 38: ...Pilot Assy S I T 3 flame LP 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 69 Valve Shield 70 Valve Bracket 71 260 042 Valve Gasket 73 Valve Cover Plate 74 Valve Access Door 75 350 930 Log Set Part...

Страница 39: ...turned to FPI and evaluated for manufacturer defect The authorized selling dealer is responsible for all in field service work carried out on your Waterford product FPI will not be liable for results...

Страница 40: ...________________________________________________ Printed in Canada Hampton is a trademark of FPI Fireplace Products International Ltd Hampton fireplace products are designed with reliability and simpl...

Отзывы: