36
Hampton
®
H27 Direct Vent Freestanding Gas Stove
INSTALLATION
3)
Slide side shelf down on to bolts.
4)
Tighten bolts to secure.
5)
Repeat steps 3 & 4 for the other side.
6)
Re-install the Cast Top.
CAUTION
Do not connect the
millivolt remote control wires
to the 120V wires.
REMOTE CONTROL
Use the Hampton
®
Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1)
Choose a convenient location on the wall
WALL THERMOSTAT
A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams.
Note that the wires are connected to the "TH"
on the gas valve. Use table below to determine
the maximum wire length:
Note: Preferable if the thermostat is installed
on an interior wall.
Hampton
®
offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
Thermostat Wire Table
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
to install the receiver and the receptacle box (pro-
tection from extreme heat is very important).
Run wires from the fi replace to that location,
use Thermostat Wire Table.
2)
Connect the wires as per the wiring diagram
below.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.
OPTIONAL SIDE SHELVESIN-
STALLATION
Bolts
3)
Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.
1)
Lift off the Cast Top.
2)
Install 2 bolts with lock washers on the inside
top of the left and right side cast panels - (do
not tighten bolts all the way).