Hampton® H15-10 Direct Vent Freestanding Gas Stove

 | 

10

installation

LOCATING YOUR  

GAS STOVE

 
When selecting a location for your stove, ensure 
that the clearances listed above are met as well 
as ensuring that there is adequate accessibility for 
servicing and proper operation.
A)  Cross Corner 

MANUFACTURED MOBILE 

HOME ADDITIONAL 

REQUIREMENTS

1)

  Ensure that structural members are not cut or 

weakened during installation.

2)

  Ensure proper grounding using the #8 ground 

lug provided.

3)

  Appliance must be anchored to the floor with 

the supplied anchoring methods. 

COMBUSTION AND 

VENTILATION AIR

The  combustion  air  from  this  appliance  is  drawn 
from  outside  the  building  through  the  outer  flue. 

Extra provision for combustion air inside the 
room is not required.

B)  Room Divider
C)  Island 

 

D)  Flat on Wall
E)  Flat on Wall Corner 
F)  Flush with Wall/Alcove

For Vent Termination requirements, see the "Exterior 
Vent Terminal Locations" section.

* 12' max. only if vertical height is achieved.

CLEARANCES TO 

COMBUSTIBLES

The  clearances  listed  are  MINIMUM  distances. 
Measure the clearance to both the appliance and 
the chimney connector. 

The farthest distance is 

correct if the two clearances do not coincide.

 

For example, if the appliance is set as indicated in 
one of the figures but the connector is too close, 
move the stove until the correct clearance to the 
connector is obtained.  

This  appliance  may  be  installed  only  with  the 
clearances  as  shown  in  the  situations  pictured. 

Do not combine clearances from one type of 
installation with another in order to achieve 
closer clearances.

This unit can be installed on a solid combustible 
surface  like  a  wood  floor.  This  unit  can  also  be 
installed directly on carpeting or vinyl.

Use  the  minimum  clearances  shown  in  the  dia-
grams below:

H15-NG10 & H15-LP10 Clearances

A  Left Side Wall to Unit

*

 

6"  / 150 mm

*B Back Wall to Unit 

0"  / 0 mm

C  Vertical Vent Pipe to Back Wall 
   

2"  / 50 mm

E  Unit Corner to Wall 

2"   / 50 mm

  Unit Top  to Alcove Ceiling   24"  / 610 mm

Minimum ceiling height is 24" /610 mm from top 
of unit.

*IMPORTANT

It is recommended that unit is moved away from 
the wall, if installing the blower option, so the fan 
can be easily installed and/or serviced.

Lift light assy bracket off bolts to install

 bulb

Remove one screw in location shown

4

. Install bulb.

Note:

 Oils from hands will shorten the life of the bulbs,

do not handle bulbs with bare hands.

5

. Reverse steps.

2.

  Loosen bolts securing cast front–slide light as-

sembly bracket upward to release.

3

. Remove one (1) screw to remove bulb housing.

ACCENT LIGHT BULB  

INSTALL

Accent light bulb is packed in the manual pack.

1.

 Lift off cast top and place on a soft surface.

Содержание H15-NG10

Страница 1: ...mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your bu...

Страница 2: ...d appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model H15 10 has been approved by Warnock Hersey Intertek for both safet...

Страница 3: ...ensions with vertical vent 5 Installation Important Message 8 Specifications 8 Mobile Manufactured Homes After First Sale 8 Before You Start 8 General Safety Information 9 Installation Checklist 9 Cle...

Страница 4: ...RIZONTAL VENT 22 7 8 19 3 8 24 11 16 20 11 16 17 13 16 19 1 8 14 1 4 13 5 8 21 1 4 19 1 8 525mm 451mm 485mm 540mm 626mm 581mm 492mm 345mm 485mm 361mm ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL...

Страница 5: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 5 5 dimensions UNIT DIMENSIONS WITH VERTICAL VENT...

Страница 6: ...ements minimaux aux mat riaux combustibles Serial No No de s rie 919 447a This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 o...

Страница 7: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 8: ...make you aware of the following CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON THE APPLIANCE...

Страница 9: ...ssageways of the appliance be kept clean and free from excessive lint from carpeting 4 See general construction and assembly in structions The appliance and vent should be enclosedwheninstalledinorpas...

Страница 10: ...nce is set as indicated in one of the figures but the connector is too close move the stove until the correct clearance to the connector is obtained This appliance may be installed only with the clear...

Страница 11: ...as shown On either side of the unit there will be slits located on the body of the stove Slide the fan up into the slits until the mounting holes line up with the holes locatedonthefanassembly Secure...

Страница 12: ...tches securing glass door and remove door 1 Open the front panel and remove the cover plate by removing two screws 6 To reinstall reverse steps 3 Remove 2 bolts and lift off cast front place front car...

Страница 13: ...ts products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingtheneedtouseheated room air for combustion and losing warm room...

Страница 14: ...of center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air i...

Страница 15: ...stable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 B...

Страница 16: ...N A N A N A N A N A TM 4ST36 N A Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK VDV KW04 Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB S...

Страница 17: ...Vent SelkirkDirect Temp AmeriVent Direct venting and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of...

Страница 18: ...et with min of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 fe...

Страница 19: ...ote min 1 foot be tween90o elbowsisrequired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min With these options max total pipelengthis30feetwithmin of6feettotalverti...

Страница 20: ...tibles May be installed in Manufactured Mobile Homes after first sale Horizontal Terminations for All Venting Systems The shaded areas in the diagram below show all allowable combinations of vertical...

Страница 21: ...m flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contours which the flexible liner will accommodate However...

Страница 22: ...pipe to length Attachthe 45o elbowtotherigid pipe and ensure that the pipe length when cut with the 45o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats...

Страница 23: ...hardening mastic should be run around both the termination and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia flex...

Страница 24: ...6 5 8 Dia x 18 Black Pipe 1 4 Dia x 18 Aluminum Vent 1 946 202 Wall Penetration Heat Shield Wall Thimble 2 pcs 1 640 530 P Riser Vent Terminal 1 640 545 P Decorative Wall Trim Black 1 948 128 Tube Mil...

Страница 25: ...stible surfaces is 1 1 4 inch Be sure to check the vent termination clearance requirements from decks windows soffits gas regulators air supply inlets and public walkways as specified inthe ExteriorVe...

Страница 26: ...inch rise for every 1 foot of run towards the ter mination Neverallowtheventtorundownward This could cause high temperatures and may present the possibility of a fire b The location of the horizontal...

Страница 27: ...ly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Diagram 5 c Before connecting...

Страница 28: ...is installed under the roofing material and not nailed down until the chimney is installed This allows for small adjustments Note If an offset is necessary in the attic toavoidobstructions itisimporta...

Страница 29: ...lot Ignition atalltimes Thiswillavoidnuisance pilot outages during operation of this appli ance See Remote manual for setup of this IPI CPI switch 1 Remove the existing chimney cap 2 Measure the dista...

Страница 30: ...imney in a convenient location as near as possible to the appliance outlet Cut and frame a hole in the roof for the support The sides of this hole must be vertical with 1 1 4 clearance 2 Place the sup...

Страница 31: ...specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do...

Страница 32: ...he pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1 2 wrench and discard Use another wrench to hold on to the el...

Страница 33: ...Center Front Log e Embers f Platinum Embers 946 669 supplied with packaged manual Left Front Log Right Front Log 4 Remove Glass front see instructions in manual 3 Remove Cast Front and set the light a...

Страница 34: ...of burner to the other If there is any flame hesitation check that area for any blockage of the burner ports 11 Re install the Glass Front Cast Front and Top 8 Take the embers and place on the burner...

Страница 35: ...nit may be operated by a back up battery system 1 Open the right when facing front of appliance access panel by removing 1 screw 2 Install 4AA batteries into the battery holder Note Remove the batteri...

Страница 36: ...Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong recep tacle Do...

Страница 37: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 37 37 operating instructions WIRING DIAGRAM WITH THERMOSTAT Thermostat Optional Millivolt...

Страница 38: ...lipping the main ON OFF switch located behindthefrontcoverplate totheOFFposition IMPORTANT The remote control system supplied with this appliance has several options for starting operatingtheappliance...

Страница 39: ...oard will go into lock out The system will need to be reset as follows a Wait 5 minutes turn the system off by pressing the ON OFF button on the remote b After approximately 2 seconds turn on ON OFF s...

Страница 40: ...nsult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas la lettre les instructions dans la pr sente notice risquede d clencher un incendie ou une explosion e...

Страница 41: ...the thermocouple and 1 flowing across the rear of the burner it does not have to be touching the burner Note If you have an incorrect flame pattern contactyourHampton dealerforfurther instructions Nev...

Страница 42: ...ch as Wall Straps or plumbers tape for rigidity LOG REPLACEMENT Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the log...

Страница 43: ...ve 2 bolts and lift off cast front place front carefully on a soft surface 1 Turn off stove and allow to return to room temperature 2 Shut off electrical supply 3 Lift off cast top and place on a soft...

Страница 44: ...two 2 switch wires from valve 5 Lift off the Cast Top and remove the Cast Front and glass door see detailed instruction in this manual 6 Carefully move light bracket out of the way Screws 7 Carefully...

Страница 45: ...e Comes With Legs 2 Per Side Sea side Sand W801015 Touch Up Paint Brown 938 317 Touch Up Paint Seaside Sand 9 382 515 Rear Panel Assembly 11 382 516 Valve Cover Assembly 12 382 005 Safety Screen Assy...

Страница 46: ...rgrated Fireplace Control Proflame 11 584 306 911 175 Hand Held Remote Control GTMFL 0 584 042 911 179 ASM 120 Volt Power Cord Assembly 911 173 Valve Remote Wiring Harness 584 924 911 177 4 Position W...

Страница 47: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 47 47 notes...

Страница 48: ...dule Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware...

Страница 49: ...ages downdrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels...

Страница 50: ...nal legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the ev...

Страница 51: ...below in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Pro...

Страница 52: ......

Страница 53: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 53 53 notes...

Страница 54: ...54 Hampton H15 10 Direct Vent Freestanding Gas Stove 54 notes...

Страница 55: ......

Страница 56: ...e Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Pho...

Отзывы: