10
|
Hampton® H15-10 Direct Vent Freestanding Gas Stove
|
10
installation
LOCATING YOUR
GAS STOVE
When selecting a location for your stove, ensure
that the clearances listed above are met as well
as ensuring that there is adequate accessibility for
servicing and proper operation.
A) Cross Corner
MANUFACTURED MOBILE
HOME ADDITIONAL
REQUIREMENTS
1)
Ensure that structural members are not cut or
weakened during installation.
2)
Ensure proper grounding using the #8 ground
lug provided.
3)
Appliance must be anchored to the floor with
the supplied anchoring methods.
COMBUSTION AND
VENTILATION AIR
The combustion air from this appliance is drawn
from outside the building through the outer flue.
Extra provision for combustion air inside the
room is not required.
B) Room Divider
C) Island
D) Flat on Wall
E) Flat on Wall Corner
F) Flush with Wall/Alcove
For Vent Termination requirements, see the "Exterior
Vent Terminal Locations" section.
* 12' max. only if vertical height is achieved.
CLEARANCES TO
COMBUSTIBLES
The clearances listed are MINIMUM distances.
Measure the clearance to both the appliance and
the chimney connector.
The farthest distance is
correct if the two clearances do not coincide.
For example, if the appliance is set as indicated in
one of the figures but the connector is too close,
move the stove until the correct clearance to the
connector is obtained.
This appliance may be installed only with the
clearances as shown in the situations pictured.
Do not combine clearances from one type of
installation with another in order to achieve
closer clearances.
This unit can be installed on a solid combustible
surface like a wood floor. This unit can also be
installed directly on carpeting or vinyl.
Use the minimum clearances shown in the dia-
grams below:
H15-NG10 & H15-LP10 Clearances
A Left Side Wall to Unit
*
6" / 150 mm
*B Back Wall to Unit
0" / 0 mm
C Vertical Vent Pipe to Back Wall
2" / 50 mm
E Unit Corner to Wall
2" / 50 mm
Unit Top to Alcove Ceiling 24" / 610 mm
Minimum ceiling height is 24" /610 mm from top
of unit.
*IMPORTANT
It is recommended that unit is moved away from
the wall, if installing the blower option, so the fan
can be easily installed and/or serviced.
Lift light assy bracket off bolts to install
bulb
Remove one screw in location shown
4
. Install bulb.
Note:
Oils from hands will shorten the life of the bulbs,
do not handle bulbs with bare hands.
5
. Reverse steps.
2.
Loosen bolts securing cast front–slide light as-
sembly bracket upward to release.
3
. Remove one (1) screw to remove bulb housing.
ACCENT LIGHT BULB
INSTALL
Accent light bulb is packed in the manual pack.
1.
Lift off cast top and place on a soft surface.
Содержание H15-NG10
Страница 5: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 5 5 dimensions UNIT DIMENSIONS WITH VERTICAL VENT...