background image

 14
 

 

The heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the 
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

 

Certain materials or items, when stored under the heater, will be subjected to radiant heat and could be seriously damaged.

 

Inspect the visible portion of the hose before each use of the appliance. The hose inside cylinder pole housing should be checked 
annually and a leak test should be performed when re-assembled.

 

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing 
ignition.

 

Young children should be carefully supervised when they are in the area of the heater.

 

Clothing or other flammable materials should not be hung from the heater, or placed on or near the heater.

 

Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater.

 

Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least 
annually by a qualified service person.

 

More frequent cleaning may be required as necessary. It is imperative that control compartment, burners and circulating air 
passageways of the heater be kept clean.

 

Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

 

Do not obstruct the flow of combustion and ventilation air.

 

Keep the ventilation openings of the cylinder enclosure free and clear from debris.

 

The LP-gas supply cylinder to be used must be: a. Constructed and marked in accordance with the specifications for LP-gas 
cylinders of the U.S. Department of Transportation (DOT); or the Standard for cylinders, Spheres and Tubes for Transportation of 
Dangerous Goods and Commission, CAN/CSA-B339, as applicable; b. Provided with a listed overfilling prevention device; and c. 
Provided with a cylinder connection device compatible with the connection for the appliance. d. 20LB (9kg) cylinder. LPG capacity 
4.7 gallons (17.8 litres) Cylinder Dimensions: Height 17.75 in. (451 mm) and width 12.25 in. (311 mm) e. The LP - gas cylinder used 
must include a collar to protect the cylinder valve.

 

A cylinder must be stored outdoors in a well-ventilated area out of reach of children. A disconnected cylinder must have dust caps 
tightly installed and must not be stored in a building, garage or any enclosed area. The pressure regulator and hose supplied must 
be used and any replacement pressure regulator or hose must be those as specified by the manufacturer.

 

Do not store spare LP-gas cylinder under or near this appliance.

 

Never fill the cylinder beyond 80% full; and for appliances designed to use a CGA No. 791 Connection: Place the dust cap on the 
cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve that is provided with 
the cylinder valve. Other types of caps or plugs may result in leakage of propane.

POSITIONING INSTRUCTIONS

 

This appliance is for OUTDOOR USE ONLY and should be placed in a well ventilated area.

 

A well ventilated area must have a minimum of 30% of its surface area open. (Surface area is defined as the total surface of the 
walls surface.)

 

The sides of the appliance should NEVER be closer than 40 in. (1 m) from any combustible surface.

 

Keep this appliance away from any flammable materials!

40 in. (1M)

40 in. (1M)

Operation

Содержание 882731

Страница 1: ...t us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay USE AND CARE GUIDE 38 200 BTU BRONZE HEAT FOCUSING PROPANE GAS PATIO HEATER Qu...

Страница 2: ...onnected for use shall not be stored in the vicinity of this or any other appliance WARNING For Outdoor Use Only WARNING Improper installation adjustment alteration service or maintenance can cause pr...

Страница 3: ...icular attention must be taken Store the unit away or ensure it is at a safe distance from other items in the event that the unit is blown over WARNING Only use with gazebo s specifically designed to...

Страница 4: ...s receipt WHAT IS NOT COVERED Defects or damage caused by the use of other genuine parts are not covered by this warranty This warranty is valid for the original customer only and excludes product da...

Страница 5: ...ARDWARE INCLUDED NOTE Hardware not shown to actual size Part Description Quantity AA 1 4 in dome head bolt 27 BB 1 4 in nut 33 CC 1 4 in hex bolt 19 DD 1 4 in washer 7 EE 5 16 in washer 3 FF 5 16 in b...

Страница 6: ...hamber Supports A B C Lower Support Pole Cylinder Chamber Wall Cylinder Chamber Door Cylinder Chamber Top A B D C G H E I K L Quantity 1 3 1 1 1 1 Part G H I J K L Description Upper Support Pole Lante...

Страница 7: ...ght Overall Width Heater Heat Input Qn Heater Gas Consumption Heater Injector Size Setting Pressure Regulator Outlet Pressure Standard Gas Supply Pressure 95 in approx 82 6 lbs 34 in 38 200 Btu h 1 77...

Страница 8: ...corresponding section on the base A with six of the bolts CC Finger tighten only at this stage 2 Attaching the lower support pole Attach the lower support pole C to the cylinder chamber supports B usi...

Страница 9: ...amber wall Using six of the bolts AA and nuts BB attach the cylinder chamber wall D to the cylinder chamber supports B Finger tighten only at this stage 4 Attaching the cylinder chamber door Hang the...

Страница 10: ...the lower support pole C as shown and secure to the cylinder chamber supports B using three bolts AA and three nuts BB 6 Attaching the upper support pole Attach the upper support pole G to the lower s...

Страница 11: ...as cylinder turn clockwise to tighten it securely Position the gas cylinder inside the cylinder chamber as shown securing with the chain Perform a Leak Test see page 16 NOTE THE CYLINDER MUST BE POSIT...

Страница 12: ...the assembled side panels L using six bolts AA and nuts BB and then fully tighten all bolts WARNING While every precaution has been made in the manufacture of this product care must be taken during a...

Страница 13: ...her assistance 11 Attaching the reflector to the lantern Fit the reflector to the lantern H using three bolts FF and washers EE Assembly continued 12 Fitting the battery Unscrew sparker button 1 and i...

Страница 14: ...nstructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT or the Standard for cylinders Spheres and Tubes for Transportation of Danger...

Страница 15: ...s an overhead cover and three side walls as long as 30 or more of the horizontal periphery of the enclosure is permanently open LIGHTING INSTRUCTIONS Fit battery to sparker Turn on the gas supply at t...

Страница 16: ...in this manual Leak test annually and whenever the gas bottle is removed or replaced GAS AND REGULATOR The gas hose must be connected in accordance with these instructions When installed correctly al...

Страница 17: ...be operated without the reflector in place If the heater is to be stored indoors the gas bottle must be disconnected and left outside in a dry well ventilated area away from any sources of heat or ig...

Страница 18: ...Page intentionally left blank...

Страница 19: ...Page intentionally left blank...

Страница 20: ...problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for fu...

Отзывы: