16
LEAK TESTING
Your patio heater has been checked at all factory connections for leakage. To check the connection at the gas hose/regulator/cylinder:
□
Ensure you are in a well ventilated area.
□
Confirm all control knobs are in the off position.
□
Open the gas control valve on the bottle.
□
Check for leaks by brushing a solution of 50% water and 50% dish soap over the gas system joints, including all valve connections,
hose connections and regulator connections.
□
NEVER USE AN OPEN FLAME to test for leaks at any time.
□
If bubbles form over any of the joints, there is a leak.
□
Turn off the gas supply and retighten all joints.
□
Repeat test. If bubbles form again, do not use the patio heater. Please contact the helpline stated in this manual.
□
Leak test annually and whenever the gas bottle is removed or replaced.
GAS AND REGULATOR
□
The gas hose must be connected in accordance with these instructions. When installed correctly all parts of the hose should be
contained within the patio heater pole and gas cylinder chamber. No part of the hose should be outside of the patio heater body
where it could be a trip hazard or could be accidently damaged.
□
This appliance is for propane use only.
□
See instructions supplied with the regulator for correct use and attachment.
□
Gas bottles should never be stored on their side.
□
Never store gas bottles indoors.
□
This appliance is supplied with a propane regulator which must only be used for propane gas.
□
NEVER use an adjustable regulator with this appliance.
□
Please consult your gas dealer for the most suitable gas bottles for your regulator.
Operation (continued)
Hose/Regulator
Regulator/Cylinder
valve
Содержание 882731
Страница 18: ...Page intentionally left blank...
Страница 19: ...Page intentionally left blank...