background image

HAMPTONBAY.COM

Please contact 1-855-HD-HAMPTON for further assistance.

PACKAGE CONTENTS

Assembly and Installation

Attaching and installing the light

1

Item #1005 697 369

Model #62909

 

Install the fixture in the ground by pushing the stake (C).

 

Detach and place the wire connector (D) on opposite sides of the low 

voltage cable (not included) where the fixture will be located.

 

Align and fit the main low voltage cable vertically in the slot of the wire 

connector as shown.

 

Press the wire connector (D) together until it is fully seated and locked 

around the cable. Pre-set prongs will pierce the cable insulation and 

establish contact. Turn on the power unit. If the light fixture does not turn 

on, repeat operations 2 and 3.

 

Once the clip-on connector is in place, we recommend wrapping it in 

electrical tape (not included) for additional protection.

Option 1: with extension post

 

Twist the connector (2) out at the bottom of the extension post (B), and 
remove the connector (2). 

 

Attach the fixture bollard (A) to the extension post (B) by routing the fixture 
wire (1) through the extension post (B) and placing the fixture bollard 
(A) onto the threaded end of the extension post (B) and then twisting 
clockwise.

 

Route fixture wire (1) through the the connector (2) and twist the 
connector (2) back into the bottom of the extension post (B).

 

Insert the fixture wire (1) into the groove located on the top of ground 
stake (C).

 

Attach the extension post (B) to the stake (C) by placing the bottom of the 
extension post (B) onto the top of the stake (C) and twisting clockwise.

Connecting the wires

2

A - Fixture bollard x 1

B - Extension post x 1

C - Stake x 1

D - Connector with 12 in. wire length

(attached to fixture) x 1

CAUTION

: The wire from the low voltage power unit shall be 

12-16 AWG type underground Low Energy Circuit Cable.

IMPORTANT

: Protect the wiring by routing it in close 

proximity to the light or next to a building structure such as 
a house or deck.
Do not bury the wiring by more than 6 in. (15.24 cm) in order 
to connect to the main secondary wire.
Do not submerge fixtures in water.

NOTE

: Do not use a hammer. If the ground is hard, use water 

to soften it or a trowel to loosen the soil.

WARNING:

 The connector contacts (D) have sharp edges 

for piercing the main low voltage cable. To avoid injury, 
do not touch the metal contacts.

A

B

C

D

E

E - Remote control x 1

Option 2: without extension post

 

Twist the connector (2) out at the bottom of the extension post (B), and 
remove the extension post (B). Route the fixture wire (1) through the 
connector (2), and then twist the connector (2) into the bottom of the 
fixture bollard (A).

 

Attach the fixture bollard (A) to the stake (C) by placing the bottom of the 
fixture bollard (A) onto the top of the stake (C) and twisting clockwise.

2

2

3

A

B

C

A

C

1

1

1

D

Use and Care Guide

LED Low Voltage Path Light

WARNING:

 Risk of electric shock. Do not install the light 

within 10 ft. (3.05 m) of a pool, spa or fountain.

Remote Control

3

 

Prior to using the remote, remove the pull 
tab (4) at the base of the remote control 
(E) to allow battery contact.

 

Press the buttons on the remote (E) to 
select the desired mode or push the 
button (3) on the fixture bollard to select 
the desired mode.

Option 1:
with extension post

Option 2:
without extension post

4

E

Содержание 62909

Страница 1: ...nd twisting clockwise Connecting the wires 2 A Fixture bollard x 1 B Extension post x 1 C Stake x 1 D Connector with 12 in wire length attached to fixture x 1 CAUTION The wire from the low voltage power unit shall be 12 16 AWG type underground Low Energy Circuit Cable IMPORTANT Protect the wiring by routing it in close proximity to the light or next to a building structure such as a house or deck ...

Страница 2: ...ree from defects in materials and workmanship for a period of five 5 years from date of purchase This warranty applies only to the original consumer and only to products used in normal use and service If this product is found to be defective the manufacturer s only obligation and your exclusive remedy is the repair or replacement of the product at the manufacturer s discretion provided that the pr...

Страница 3: ...ables 2 A Bolardo de la lámpara x 1 C Extensión de poste x 1 C Estaca x 1 D Conector con cable de 30 5 cm 12 plg conectado a la lámpara x 1 PRECAUCIÓN El cable de la unidad de energía de bajo voltaje será uno de Circuito de Bajo Consumo de Energía soterrado del tipo AWG calibre 12 16 IMPORTANTE Protege el cableado pasándolo muy cerca de la lámpara o cerca de una estructura como una casa o terraza ...

Страница 4: ...os postes de conexión positivo y negativo Cada cable debe estar bien atornillado y sin contacto con ningún otro QUÉ CUBRE LA GARANTÍA El fabricante garantiza que esta lámpara no presentará defectos materiales o de fabricación por un período de cinco 5 años a partir de la fecha de compra Esta garantía es válida solo para el consumidor original y cubre solo productos en uso y servicio normales Si es...

Отзывы: