24
Hammer Engines GmbH / IQ-Serie / Betriebsanleitung
(5) STARTER TEST
Using
the starter motor can be operated manually.
___________________________________________________________________________
↓
IMPORTANT! Using this menu you can adjust all vital parameters of your
turbine. These settings are meant for experts only. This menu is disabled by
default!
Auto-Calibration procedure
1. Ramp up to calibration rpm
2. Stabilization
3. Idle rpm are being adjusted
4. The turbines response curve is being calculated
Course of normal operation
Characteristic features of normal operation:
•
Temperature/RPM dependent control of fuel feed
•
Monitoring of RPM and temperature limits
•
Recording of all relevant data (BLACKBOX)
•
Telemetry transmission
Failsafe operation
The ECU comes with a failsafe setting which becomes active should rpm or temperature
sensors fail (Status: EMERGENCY). In this mode the turbine will be controlled by pump-
voltage alone. A pre-occurring one-time stabilization of full throttle is necessary (Status:
AUTO-HC). The cause of error needs to be eliminated before the turbine can be started again.
Safety features
•
RPM: exceed – fall below - failure
•
Temperature: exceed – fall below - failure
•
Power: Minimum voltage
•
Output Fuel pump: failure/short circuit
•
Input receiver: failure –glitch –Fail Safe