background image

MULTIFUEL STOVE VERSION-
MULTIFUEL GRATE

GRATE

The grates in the Hamlet Solution multifuel units
comprise a series of reciprocating cast iron bars
seated on a pivoted "comb". All bars in the grate are
identical, but every other bar is turned through 180
degrees, with the ends of the bars marked "H" sit-
ting on the high sections of the comb, and the ends
marked "L" sitting on the low sections.

ASSEMBLING THE GRATE

To assemble the grate, fit bars to low sections of the
comb first, inserting end marked "H" into rear
channel with groove on underside of bar located on
upstand tab, and then lowering end marked "L"
onto the low section of the comb, see fig. 7. The
upper bar is fitted in a similar manner, but with the
end marked "L" inserted in the rear channel, and
the end marked "H" seated on the high section of
the comb. See fig. 8. for the assembled grate layout.

GRATE BAR REPLACEMENT

After extended use it may be necessary to replace
some of the grate bars. Periodic inspection of the
bars is recommended and the removal of any nails
or wire that may be present after burning wood. All
the grate bars in each appliance are identical and
can easily be lifted out after removal of the fuel
retainers. Remove damaged grate bars and replace
with casting of the same type, fitting as per
instruction above. When re-ordering replacement
grate bars, see page 31of these instructions for the
correct spare part code.

Hamlet Solution Wood & Multifuel Stoves

15

INSTALLATION

Fig. 7. Fitting the grate bars

Fig. 8. Assembled grate

Содержание Solution

Страница 1: ...Wood Multifuel Model Range Operating Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Solution 7 Multifuel Rev 3 November 2006 AFS1292 SOLUTION BK054...

Страница 2: ...the reliability of our product that we offer a Lifetime Guarantee Should you have any questions about our Solution Stoves that are not covered in this manual please contact the Hamlet dealer in your a...

Страница 3: ...Annual Maintenance 21 Summer Storage Non Usage 21 Door Adjustment 21 Dissassemble Airwash 22 Fuel Retaining Bars Inspection 22 Fire Door Glass 23 Service Record 24 OPERATING INSTRUCTIONS Fuel Types 25...

Страница 4: ...D IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www solidfuel co uk THE USE OF SPARE PARTS O...

Страница 5: ...fire If not properly installed and operated a house fire may result installation must comply with the Building Regulations and conform to all relevant fire safety standards Hamlet Stoves produce a var...

Страница 6: ...otplate 6 Rear liner 7 Side liners 2 N A SOL 7 Wood 1 5 2 2 SOL 7 Multifuel N A SOL 5 Wood 1 4 2 7 1 5 2 SOL 9 Wood SOL 9 Multifuel 2 1 4 1 5 1 4 1 5 1 Grate bars 1 1 2 Wood burning tray SOL 11 Multif...

Страница 7: ...Instruction Manual 13 Operating tool 1 1 SOL 7 Wood 1 SOL 7 Multifuel SOL 5 Wood 1 1 SOL 9 Wood SOL 9 Multifuel 8 Rear grate bar support 11 Fire door han dle Kool Touch 1 1 1 SOL 11 Multifuel SOL 11...

Страница 8: ...1 5 SOL 5 Wood 3 2 1 7 8 4 8 2 2 SOL 9 Wood SOL 9 Multifuel Measured from rear of canopy to the tip of the handle The model and Serial Number of your stove can be found stamped into the casing centra...

Страница 9: ...tion HEARTH The stove should be installed to stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Dimensions of the hearth shoul...

Страница 10: ...stove outlet to the outside air To ensure a good up draught it is important that the flue gases are kept warm and that the flue size suits the stove The termination of the outlet at the top of the flu...

Страница 11: ...ent J of the Building Regulations for England and Wales is available from The Stationery Book shops and can also be viewed at the ODPM website at www safety odpm gov uk bregs brads htm Details on the...

Страница 12: ...12 Hamlet Solution Wood Mutifuel Stoves INSTALLATION Fig 2 A Typical Rear Flue Layout...

Страница 13: ...TYPICAL METAL INSULATED CHIMNEY SYSTEM TO BE INSTALLED TO THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULATIONS AND BS7566 PTS 1 4 A is minimum clearance for non insulated flu...

Страница 14: ...or the other rear leg WOOD STOVE VERSION WOOD TRAY The wood burning tray should come fitted in your stove if not please follow these instructions Fully open the fire door and remove the two round fuel...

Страница 15: ...e upper bar is fitted in a similar manner but with the end marked L inserted in the rear channel and the end marked H seated on the high section of the comb See fig 8 for the assembled grate layout GR...

Страница 16: ...small liner s into the back of the fire Insert side liner panels See Fig 10 Fit the throat plate with the single bend and two cut outs to the front facing up The projecting lugs sit on top of the sid...

Страница 17: ...s for individual heating systems should be carried out by a qualified heating engineer In many cases your supplier will be able to offer advice and assistance Direct Systems Stainless steel boilers ei...

Страница 18: ...ipe from the expansion tank should be 28mm diameter copper Pipes in unheated spaces must be lagged FINAL CHECK Before handing over the installation to the customer it is strongly recommended that the...

Страница 19: ...e calculated natural draught gas appliances only c If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used d If an exis...

Страница 20: ...uch up spray as some paints interact This could ruin the finish and invalidate the guarantee DOOR GLASS The door glass should remain clear during normal daytimeburning Howeverundercertainconditions su...

Страница 21: ...w air movement through the stove by opening the airwash and prinmary air inlet s controls to about half way open or leave the door ajar This will allow a free flow of air through the appliance thus pr...

Страница 22: ...let Lift outer cover free from body being careful not to damage the ends of each lug Fig 15 Slide off the spacer tube from the centre stud and retain for re assembly Unscrew the inner slider and clean...

Страница 23: ...olts on the inside of the door securing the retaining clips Carefully remove any pieces of broken glass and sealing gasket wearing suitable gloves Re place the gaskets and line them up in relation to...

Страница 24: ...our Solution Stove that is not covered in this manual please contact your Hamlet Stoves retailer Please keep all repair receipts safely Please ensure you have this manual available when an engineer vi...

Страница 25: ...hurnacite Plus Centurion Maxibrite Extracite Pureheat Blazebrite Taybrite Sunbrite Doubles Singles Anthracite Large Nuts and Welsh Dry Steam Coal Large Small Nuts Approval does not cover the use of ot...

Страница 26: ...r long periods consequently more care in setting the controls and some familiarisation is necessary when burning anthracite Use the smallest size fuel Stovesse or Small Nuts Proceed as for manufacture...

Страница 27: ...s housed in a cover plate and is located above the fire door Sliding the control knob to the right as far as it will go achieves the fully open position Sliding it to the left will shut off the air in...

Страница 28: ...de ashing is complete re set grate to previous position Empty the ash pan Note Do not force the riddling lever TO EMPTY THE ASH PAN Open the fire doors Fit the fork end of the operat ing tool into th...

Страница 29: ...draught is not present in the chimney Fire door is closed If the fire goes out with unburnt fuel left in the firebox increase the air opening slightly and vice versa In the morning Open the air contro...

Страница 30: ...erosol Paint Gothic Tracery SOL 11 Multifuel SOL 11 Wood Lattice Tracery AFS 101a AFS 101a AFS 101a AFS 101a AFS 101a AFS 101a AFS 101a AFS 101a AIB 0 AIB 0 AIB 8 AIB 8 AIB 9 AIB 9 AIB 10 AIB 10 Stove...

Страница 31: ...2 Wood burning tray SOL 11 Multifuel SOL 11 Wood 3 Throat plate N A N A AFS 1197 AFS 1286 AFS 1286 AFS 1287 AFS 1287 AFS 009a AFS 009a AFS 010 AFS 010 AFGS 064 AFGS 064 AFS 009 AFS 009 AFS 1207 AFS 1...

Страница 32: ...AFS 008 AFS 008 AFS 008 AFS 1214 AFS 1214 AFS 1215 AFS 1215 AFS 1010 AFS 1010 AFS 1010 AFS 1010 AFS 047 AFS 047 AFS 047 AFS 047 AFS 1205 AFS 1208 AFS 1208 AFS 058 AFS 058 AFS 051 AFS 051 12 Replaceme...

Страница 33: ...ire Door Rope Kit Complete With Glue AFS 1021 SOL 11 Multifuel SOL 11 Wood AFS 1294 AFS 1294 AFS 1295 AFS 1295 AFS 1222 AFS 1222 AFS 1222 AFS 1222 AFS 1292 AFS 1292 AFS 1292 AFS 1292 N A AFS 1226 N A...

Страница 34: ...final If your appliance proves to be defective as a result of faulty materials or workmanship during the guarantee period we will repair or replace it FREE OF CHARGE as long as the fire has been inst...

Страница 35: ...any other costs including labour incurred in its replacement Documentation must be retained and produced in the event of a warranty claim This guarantee specifically does not cover accidental damage m...

Страница 36: ...BARS WOODBURNING TRAY FIREBOX LININGS THROAT PLATE AIR WASH DOOR CATCH KOOL TOUCH HANDLE ASH PAN ADJUSTING FEET X 2 OPERATING TOOL CONVECTOR KIT FIXINGS X 4 OPERATING INSTRUCTIONS Model Serial No I ve...