IMPORTANT INFORMATION
BK 700 Specific
2 Warnings
It is a LEGAL REQUIREMENT that the installation of all new or replacement, wood or
solid fuel heating appliance, obtain building control approval from your local authority or
the installation work must be carried out through a government approved competent
persons scheme. A list of all competent person schemes can be found :
https://www.gov.uk/guidance/competent-person-scheme-current-schemes-and-how-
schemes-are-authorised
Any manufacturer’s instructions must not be taken as overriding statutory requirements.
All Hamlet Solution stoves MUST NOT be connected to a shared flue system.
Please Note: Classification of these appliances is for intermittent use only.
Do not use aerosol sprays or any other flammable materials near the appliance when in
use.
Do not use the appliance as an incinerator.
Use only recommended fuels, STRICTLY NO unsuitable and non recommended fuels or
materials or liquid fuels allowed.
Pure petroleum coke or Bituminous house coal must NOT be burned in this appliance.
The use of these fuels will invalidate the appliance guarantee.
Arada recommends the use of approved smokeless fuels which have been deemed
suitable for use on closed appliances, including multi fuel stoves.
If in doubt, contact The Solid Fuel Association, telephone: 0845 601 4406 / 01773
835400 or visit www.solidfuel.co.uk.
Please ensure that the air inlet vent grills to the dwelling are not obstructed or liable to be
blocked.
Caution must be exercised during operation of the appliance as both internal and external
surfaces will be hot to touch, use the stove mitten provided when the appliance is in
operation.
A fireguard conforming to BS 8423:2002 should be used in the presence of children or
elderly people.
Always observe the distances to combustible materials as stated on the appliance data
plate and in the technical data section of this manual. Ensure no soft furnishings or
combustible materials are susceptible to heat radiating from the appliance.
Any add in boiler options have not been certified for use in Smoke Control areas and
therefore are unsuitable for use in Smoke Control Areas.
Page 6
SOLUTION Stove User Guide