6.4 Warning - Fume / Smoke emissions 
 

Properly installed, with a suitable flue or chimney, operated and maintained correctly, this 
appliance will not emit fumes into the dwelling. Occasional fumes when de-ashing and     
refuelling may occur. However, persistent fume emission is potentially dangerous and must 
be investigated by a approved / registered installer. 

 
              Stop using the appliance if you smell fumes or see smoke escaping. 
 

If fume emission does persist, the following immediate actions should be taken: 
 
 

• Open doors and windows to ventilate room. 

 

• Let the fire die or extinguish and safely dispose of fuel from the appliance. 

 

• Check for flue or chimney blockage, and clean if required. 

 
Seek expert advice from your approved installer. Do not attempt to re-light the fire until the 
cause of the fume emission has been identified and corrected. 
 

6.5 Refuelling on to a low fire bed 
 

If there is insufficient burning material in the fire bed to light a new fuel charge, excessive 
smoke emission can occur. Refuelling must be carried out onto a sufficient quantity of   
glowing embers and ash that the new fuel charge will ignite in a reasonable period. If there 
are too few embers in the fire bed, add suitable kindling for ignition to prevent excessive 
smoke. 

Important  notes on usage to meet the requirements of Smoke Control exemption - 

 

 

Always recharge onto hot embers. 

 

After re-charging, leave the door ajar for approximately 3 minutes to establish good 
combustion. 

 

Do not leave the appliance unattended until flames are well established. 

 

Periodic burning out of the fuel bed at high output to combust any remaining charcoal. 

 
NOTE :   
The minimum air control setting is governed in manufacture to meet the requirements of 
Smoke Control exemption and as a result the appliance will NOT shut down completely when 
in the minimum air position setting. 

 
NOTE : It is recommended that wood logs are place centrally against the rear liners, 
within the firebox to ensure the most efficient use of the fuel. 

 

 
6.6 Typical wood burn for nominal output 
 

To perform the most efficient burn at the nominal rated output please consult the           
specification table at the rear of this manual. Please note, many factors can effect the   
nominal output, so the stated weights of fuel (Seasoned Hard Wood) are a guide, which is a 
representation to laboratory burn conditions. 

BK 700 Specific   

Page 15 

SOLUTION Stove User Guide 

Содержание Solution 5 Widescreen

Страница 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE BK700 SPECIFIC Rev 02 ISSUE DATE 09 11 2017 EN 13240 2011 A2 2004 SOLUTION Stove User Guide Hamlet Solution 5 Widescreen...

Страница 2: ...your stove which are not covered by this manual please contact the Arada retailer in your area call our technical support department on 44 0 1297 632050 or visit our website www aradastoves com which...

Страница 3: ...6 1 1 Fuel overloading 6 1 2 Operation with door left open 6 1 3 Dampers Air controls left open 6 2 Burning wood 6 3 Burning solid fuels 6 4 Warning Fume Smoke emissions 6 5 Refuelling on to a low fi...

Страница 4: ...t stove 10 1 Adjusting the door hinges 10 2 Liners firebricks 10 3 Throat plate 10 4 Fire door seal 10 5 Cracked glass 10 6 Chimney flue sweeping 11 Further resources reading 11 1 Information 11 2 Spe...

Страница 5: ...l Grate Riddle Bar Rear Flue Outlet NOTE Top Rear Flue Outlets Are Interchangeable Will Depend Upon Installation Top Flue Outlet Secondary Air Control Fire Door Fire Door Handle Ash Pan Fuel Retainer...

Страница 6: ...nous house coal must NOT be burned in this appliance The use of these fuels will invalidate the appliance guarantee Arada recommends the use of approved smokeless fuels which have been deemed suitable...

Страница 7: ...Secretary of State in accordance with changes made to sections 20 and 21of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015 In Scotland appliances are exempted by publication on a lis...

Страница 8: ...the moisture content of your wood fuel Wet wood must not be used as this will greatly contribute to the creation of tar and creosote which may in extreme cases run down the chimney in liquid form Thi...

Страница 9: ...ir is to be operated simultaneously If an extraction fan is proposed to be fitted to a connecting area of the house after the stove has been installed professional advice should be sought from a quali...

Страница 10: ...ber Primary air enters the appliance through the inlet near to the bottom of the fire door Your stove has a control slider to adjust the flow of the primary air Sliding the knob to the right will incr...

Страница 11: ...he fire door Sliding the control knob to the right as far as it will go achieves the fully open position see figure 3 Sliding it to the left will shut down the air inlet slots as shown in figure 4 Fig...

Страница 12: ...tion anti tamper screw that has been factory fitted to your stove this acts as a limit stop for the sliding air wash control and thus prevents full closure reducing smoke emissions Air Inlet Opening R...

Страница 13: ...he air inlets while igniting the stove but will then reduce this to air coming from the airwash system and over draught As much as 40 of the heat from burning wood is obtained from secondary combustio...

Страница 14: ...airwash secondary see Fig 3 4 air slider to about one quarter open and the primary air slider fully open see Fig 1 2 Light as with wood fuel see steps 1 2 and 3 on page 11 with kindling and fire light...

Страница 15: ...w fuel charge will ignite in a reasonable period If there are too few embers in the fire bed add suitable kindling for ignition to prevent excessive smoke Important notes on usage to meet the requirem...

Страница 16: ...ake s before leaving the stove to extinguish perhaps when retiring to bed as this can lead to a cooling of the stove and flue also resulting in incomplete com bustion sooty deposits and high levels of...

Страница 17: ...throat plate outside of the stove Check all moveable components at regular intervals to ensure they are moving freely Allow air movement through the stove by opening the airwash and primary air inlet...

Страница 18: ...ove comprises of a series of reciprocating cast iron bars seated on a pivoted comb These should come pre assembled in your new stove All bars in the grate are identical but every other bar is turned 1...

Страница 19: ...at the objects they strike It is then these objects such as the chimney breast hearth etc which heat the surrounding air Please note the Solution 5 Widescreen stove models have a heat shield fitted at...

Страница 20: ...med fire poker If the liners are still staying in situ and are able to support the throat plate correctly there is no need to replace them Cracked liners will not in themselves effect the performance...

Страница 21: ...zed bristle brush and rods to suit chimney size and type As with all appliances regular sweeping of the flue chimney is essential to avoid dangers of blockage and the escape of poisonous fumes Access...

Страница 22: ...about your stove and associated articles Arada Technical Support 01297 632052 technical aradastoves com Arada Stoves Support Site www aradastoves com support Competent Person Schemes https www gov uk...

Страница 23: ...such use The following guarantee periods shall apply in respect of the following Arada stoves Hamlet stoves come with a TEN year guarantee to the main body The external paint finish carry a one year g...

Страница 24: ...ered by this guarantee Firebox linings Grate bars Fuel retainer Throat plate Gaskets Door glass Seals 9 The guarantee does not cover damage caused by storing or using the stove in a damp environment d...

Страница 25: ...ing standards office s or a citizens advice bureau If you believe your appliance is not working correctly or it has broken down in the first instance please contact your local retailer or installer fo...

Страница 26: ...erials mm Rear 300 Side 300 Height mm 600 Width mm Across Canopy 541 Depth mm Inc Handle 365 Height To Centre Of Rear Flue mm 484 Depth From Back To Flue Centre mm 108 Flue Diameter mm 127 5 Weight Pa...

Страница 27: ...Page 27 BK 700 Specific SOLUTION Stove User Guide 14 Notes...

Страница 28: ...enue Axminster Devon EX13 5HU United Kingdom www aradastoves com T 44 0 1297 632050 Email info aradastoves com DATE OF ISSUE 09 11 2017 SOLUTION Stove User Guide Hamlet is a brand name of Arada Ltd Al...