BK 700 Specific
5.1.3 Smoke Exemption Permanent Stop
The position of this permanent stop has been determined during independent laboratory
testing to PD 6434:1969 to enable the smoke particulate emissions to comply with the
smoke exemption regulations.
Part of the permanent stop mechanism comprises of a restriction (anti tamper) screw, that
has been factory fitted to your stove, this acts as a limit stop for the sliding air wash control
and thus prevents full closure, reducing smoke emissions.
Air Inlet Opening
Restriction Anti Tamper Screw.
Note : Screw Is Only Visible
When The Fire Door Is Open.
Secondary Air Control
Note : Sliding Movement Is Limited
By Restriction Screw.
Visible Open Air Inlet
Note : With The Slider Against
The Stop Position, This
Distance Will Vary Between
Models.
The stop for the secondary air control on the ECB5FPLUS-WS is set at 50% Open.