![Hamilton 400 D Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/hamilton/400-d/400-d_installation-instructions-manual_585047005.webp)
12. Connecting the supply tubing to the humidifier (Please see Fig. 7)
Please ensure that operations
12, 13 and 14
are completed in sequence.
The plastic tubing MUST be kept away from hot surfaces (e.g. the warm air duct or the exhaust vent). Please measure
carefully before cutting.
IMPORTANT: Rough up both ends of the plastic tubing (approx. 1 inch long) with sandpaper in a rotating action
(7.11).
•
Slip the plastic compression nut (
7.9
) onto the tubing, then the rubber sleeve (
7.8
), and finally fit one of the brass inserts
•
(
7.7
,1/2” long, supplied with the brass valve) into the end of tubing.
•
Push the tubing fully into the automatic valve, tighten the plastic compression nut (
7.9
) securely by hand, then add 1/2
turn with a small wrench, without stripping.
13. Installing the supply valve on a copper pipe (Please see Fig. 13)
A plastic bag contains a brass valve and all the material required to install the water supply valve. Water is taken from the
nearest cold water pipe suitable for the supply valve installation. Shut off the main water valve.
CAUTION:
Please make sure that the piercing needle is completely recessed into the valve body by turning the handle
counter clockwise.
•
Assemble one side of top clamp (
13.1
) to bottom clamp (
13.2
) with a screw (
13.3
) and a nut (
13.4
).
•
Make sure that the rubber gasket (
13.5
) is in place over the piercing needle and position the valve assembly on the
copper water line.
•
Assemble the other side of the top clamp (
13.1
) to the bottom clamp (
13.2
) with the remaining screw and nut.
•
Tighten the two screws so that the valve is firmly attached to the water pipe. The two sides of the clamp must be parallel.
•
Turn the valve handle completely clockwise until it stops. This will pierce the copper pipe and close the valve.
•
This saddle valve is designed to be fully open or closed. Do not use it to regulate the water flow.
14. Connecting the water supply tubing to the supply valve (Please see Fig. 13)
• Slip the brass compression nut (
13.9
) onto the plastic tubing, then the nylon sleeve (
13.7
) with its most tapered end towards
the end of tubing.
Fit the second brass insert (
13.8
, 1/2” long, supplied with the brass valve) into the end of tubing.
Push the tubing fully into the supply valve. Then tighten the brass compression nut with a small wrench.
NOTE: The brass sleeve (13.6) supplied with the brass valve is to be used only if copper tubing (optional) replaces
the plastic tubing.
15. Installing the drum
The drum shaft has a flat end (
14.6
) that fits into the motor. The opposite end of the shaft snaps into position in the centre of
the air collar.
16. Adjusting the water level (Please see Fig. 7)
•
The water level is adjusted by altering the height of the float.
•
The optimal water level in the pan is at 3/4” from the top of the water pan.
•
Open the main water valve then the supply valve installed on the water pipe.
•
Loosen the screw (
7.6
) and adjust the float in such a way that it closes the automatic valve when the water level reaches
3/4” from the top of the water pan.
•
Tighten the screw (
7.6
) when achieved.
•
Wait until the automatic valve completely closes and check all fittings. If necessary, tighten the compression nuts a little
more without stripping.
17. Installing the humidistat and the transformer (Please see Fig. 1, 2, 8 and 9)
•
This humidifier is supplied with a transformer that can be plugged in to any electric outlet. The humidistat is a duct
mounted type.
•
The RETURN duct mounting method allows a better “sensing” of all the air returned to the furnace without being
disturbed by a sudden increase in moisture level (kitchen or bathroom), thus offering superior humidity control.
•
Kit No. 4
contains all the material you need to install the humidistat.
•
The humidistat should be installed on a flat and vertical surface of the RETURN duct at 6 inches minimum from the
humidifier top (
Fig. 2
).
•
Attach the humidistat template (
#2
) on the duct.
SELF-CLEANING MODEL:
The peg (
14.7
) located at the end of the drum comes in contact with the paddle wheel at every turn.
This movement allows draining at regular intervals.