WARNINGS AND DISCLAIMER

Installation Precautions

1) This humidifier will be connected to and used under water pressure and it must be installed in such a way that if a leak
occurs, the water could not cause any damage to the property. Make sure all water connections are properly installed or water
spill could occur.

2) This humidifier is intended for use on forced warm air circulation furnaces, as well as multi-fuel furnaces where temperature
does not exceed 180°F (82ºC). Higher temperatures will damage your humidifier and possibly cause overflow condition and
water damage to your home.

3) Do not install a humidifier where surrounding temperatures may be 32°F (0ºC) or colder. Freezing water will damage the
humidifier and burst the supply pipe, resulting in home damage.

4) Do not install the humidifier or the bypass connection directly on the furnace housing.

5) Do not install the humidifier or the bypass connection on a plenum side where a cooling coil could restrict or inhibit the
airflow through the humidifier.

6) Always check that you are not about to cut or drill into any air conditioning or electrical accessory during installation.

7) Do not install a humidifier on the supply duct where the static pressure exceeds 0.4” Water Column.

8) Do not install a humidifier if the city water pressure exceeds 90 psi. Check the local codes related to pressure reduction.

9) The installation, wiring and plumbing of the humidifier must comply with national and local electrical, plumbing and building
codes.

10) Electrical wiring and water tubing must not come into contact with sharp edges or hot surfaces. For the drainable models,
please make certain the drain tube has no bends, its end placed in a floor drain and there is no resistance to the flow of the
discharged water.

11) The transformer supplied is rated for 120 V power supply. Do not connect it to an installation supplied with another voltage.

12) Do not set the humidity level higher than normally recommended, or condensation damage could occur.

Safety Warnings

1) Please beware of sharp edges when you cut into a metal duct.
2) Always shut the power off before starting the installation. An electric shock from 120 volts could cause serious injury.

1. Required tooling

Tin snips, 3/32” drill, pliers, screwdrivers, electric drill, hammer, centre punch, medium sandpaper.

IMPORTANT NOTE: 

This humidifier is supplied with RECEX ® screws that allow the use of either a Robertson or Phillips

head screwdriver.

2. Typical installations (Please see Fig. 1)

There are two frequently encountered types of installations: LOWBOY furnace (

1.1

) and HI-BOY furnace (

1.2

).

3. Principles of operation

 This humidifier uses a motor driven evaporator pad. Warm air is by-passed from the warm air plenum and forced through

the evaporator pad while it turns in the water pan. Humid air is drawn back into the return duct.

BEFORE YOU START - GENERAL SAFETY AND INSTALLATION PRECAUTIONS

Please read and understand these instructions fully before you begin this installation and save them for future reference.
The manufacturer will assume no responsibility and the warranty will be void if the user does not adhere to the following precautions.

Self-cleaning model:

All instructions pertinent only to the self-cleaning model are shaded in the following text.
The drum contains all the small parts and installation hardware. It is closed by a round metal damper (

10.B

) that 

will be used

later 

in the installation process. Open the drum to remove all the parts, then re-assemble the drum without the damper.

Содержание 400 D

Страница 1: ...ndard and Self cleaning Please read the instructions carefully before starting the installation Version 3 June 2001 400 D 800 D M 300 M 400 For future use please copy the free help line number into the space below Free help line for technical assistance 1 800 879 0123 ...

Страница 2: ...rain tube has no bends its end placed in a floor drain and there is no resistance to the flow of the discharged water 11 The transformer supplied is rated for 120 V power supply Do not connect it to an installation supplied with another voltage 12 Do not set the humidity level higher than normally recommended or condensation damage could occur Safety Warnings 1 Please beware of sharp edges when yo...

Страница 3: ...th a marker line Make a starting hole and cut a rectangular opening that will correspond to the back opening of the humidifier 7 3 4 x 6 1 2 Install the humidifier in the opening and attach it with the four screws 8 x 3 4 The ribs around the humidifier back opening must fit into the rectangular opening in the duct Check that the humidifier body is level from side to side and from back to front The...

Страница 4: ...at is closest to the motor and mark it on the bottom of the pan Carefully make the appropriate round opening by knocking it with a flat screwdriver and a hammer The drain mechanism is factory assembled to be installed on the right side of the pan If the motor is on the right side then no change is necessary If the knockout hole is not big enough to receive the drain mechanism enlarge it a little b...

Страница 5: ... Fig 13 Slip the brass compression nut 13 9 onto the plastic tubing then the nylon sleeve 13 7 with its most tapered end towards the end of tubing Fit the second brass insert 13 8 1 2 long supplied with the brass valve into the end of tubing Push the tubing fully into the supply valve Then tighten the brass compression nut with a small wrench NOTE The brass sleeve 13 6 supplied with the brass valv...

Страница 6: ...istat should be followed by a period of 24 hours to allow the general humidity level to stabilize in the house If your house remains unoccupied during the winter season adjust the humidistat to a lower set point to prevent condensation 20 Humidifier maintenance tips Do not stop nor rotate the drum manually Do not remove the drum when it is rotating as it may cause permanent damage to the motor Che...

Страница 7: ...ess steel hex nut 10 32 Drain kit Drain mechanism Rubber O Ring 0 375 ID x 0 500 OD x 0 070 Plastic hexagonal nut 7 16 24 Drain plastic tube 3 16 ID x 5 16 OD Plunger Spring Rubber O Ring 0 250 ID x 0 437 OD x 0 103 Supply valve Needle valve body top bracket Valve bottom bracket Machine screw 1 4 20 x 1 3 4 Hexagonal nut 1 4 20 Rubber gasket Brass sleeve for copper tubing Nylon sleeve for plastic ...

Страница 8: ...j ...

Страница 9: ...j ...

Страница 10: ...J ...

Страница 11: ...J ...

Страница 12: ...WARNING This diagram is not drawn to actual demensions Please use measurements given to obtain actual size J ...

Страница 13: ...ve not received a satisfactory response notify in writing Hamilton Home Products Inc PO Box 12309 Columbus Ohio 43212 HAMILTON WILL RECEIVE FREIGHT PREPAID ONLY REMOVABLE PARTS OR COMPONENTS OF SUCH DEFECTIVE PRODUCTS 7 This limited one year warranty does not apply to any part or component that is damaged in transit or handling has been subject to abuse neglect or accident has not been installed o...

Отзывы: