background image

 

OPTIONAL: 

If the damper is snugly in place and can remain in a fixed position, screw #4 may be left out. This will allow

for easier opening and closing of the air damper.

8. Installing the flexible duct (Please see the general view Fig. 2)

 Measure the required flexible duct length necessary to connect the humidifier to the air take-off collar (

2.3

), so it does not

sag.

 Cut the excess portion.

 Slide the flexible duct (

2.1

) on the air take-off collar (

2.3

) and secure it by inserting the plastic pins (

2.2

) through the vinyl

in between two reinforcement wires.

 Repeat this operation at the humidifier side.

9. Installing the automatic valve (Please see Fig. 4, 5 and 7)

 

Kit No. 2 

contains all the material you need to install the automatic valve.

 Remove the oblong knock-out to open a hole where the valve has to be installed.

 Install the valve (

7.1

) inside the casing and fasten it with the hexagonal plastic nut (

7.4

). The valve body is held in a

vertical position by two ribs (

4.4

) of the humidifier body.

 Take the float (

7.3

) and install it behind the valve lever (

7.2

) with the pivot pin (

7.5

) fitted in the round hole.

 Insert the screw (

7.6

) in the kidney-shaped opening through the valve lever (

7.2

) and the float arm (

7.3

) and screw it into

the nut (

5.1

) installed in the hexagonal housing of the float arm.

 Partially tighten the screw (

7.6

).

10. Preparing the water pan (and the draining system if necessary) Please see Fig. 15

If this humidifier is a non-self cleaning model, no special preparation is necessary and the water pan is ready to install as is.
Please go directly to 

step 11.

11. Installing the pan into the humidifier

 Slide the water pan into the humidifier, between the two plastic rails located at the sides of the unit.

 Slightly open the sides of the humidifier and insert the two side tabs of the water pan into the two rectangular holes (

4.5

)

in the sides of the humidifier.

 Push the front of the water pan down to snap the two tabs in the sides of the humidifier.

SELF-CLEANING MODEL: 

The automatic valve must be installed on the same side as the air intake.

SELF-CLEANING MODEL: 

The water pan and the draining system have to be assembled.

 The draining system must be installed on the same side as the motor.

 The water pan has two round knockouts on the bottom of the pan, located at the front left and right side.

 Locate the knockout that is closest to the motor and mark it on the bottom of the pan.

 Carefully make the appropriate round opening by knocking it with a flat screwdriver and a hammer.

 The drain mechanism is factory-assembled to be installed on the right side of the pan. If the motor is on the right side, then no

change is necessary.

 If the knockout hole is not big enough to receive the drain mechanism, enlarge it a little bit with a small cutter.

 Install the drain box in the water pan, the two screws of the cover towards the back of the pan. The box (

15.2

) has to sit between

the ribs (

15.6

) in the water pan. The paddle wheel (

15.7

) is on the right side.

 Make sure the rubber “O” ring (

15.3

) is between the drain box housing (

15.2

) and the bottom of the water pan (

15.1

).

 Secure the drain box (

15.2

) to the water pan (

15.1

) with the plastic nut (

15.4

), without stripping.

 If the motor is on the left side of the humidifier, the draining system must be reversed. Please do the following:

 After having opened the left knockout hole, install the draining system in hole of the water pan as described above.

 The paddle wheel (

17.5

) is still on the right side.

 Remove the two screws (

16.3

) retaining the cover (

16.4

) and open the draining mechanism.

 Carefully lift the inside plunger (

16.1

) and the spring (

16.2

) and remove them from the box.

 Observe how the shaft is positioned. Please note that the two ribs (

17.3

) on the shaft (

17.2

) are sitting on the right wall of the box

 (

17.1

). Take the shaft and flip it so the paddle wheel (

17.5

) is on the left side, the two ribs (

17.3

) on the shaft sitting now on the left

wall of the box (

17.4

).

 Put the plunger (

16.1

) back in its original position, then reinstall the spring (

16.2

) in the middle of the plunger.

 Hook the plastic cover (

16.4

) in the front wall of the box, making sure that the spring (

16.2

) sits around a plastic protrusion (

16.5

) in

the center of the cover (

16.4

).

 Carefully put the two screws (

16.3

) back in place to hold the cover, without stripping.

 The draining system is now reversed. Turn the paddle wheel by hand to make sure it turns freely and that it stops positively every

1/8 of a turn.

SELF CLEANING MODEL:

 Push one end of the drain hose (

11.3

) onto the draining system connector (

11.2

). The other end must be connected to a drain.

 Please install the tubing as vertical as possible and do not leave bends where water could accumulate between draining periods,

thus allowing minerals to build-up deposits in the tubing.

 The housing of the draining system is designed to protect against failure. Any overflow would be drained immediately.

Содержание 400 D

Страница 1: ...ndard and Self cleaning Please read the instructions carefully before starting the installation Version 3 June 2001 400 D 800 D M 300 M 400 For future use please copy the free help line number into the space below Free help line for technical assistance 1 800 879 0123 ...

Страница 2: ...rain tube has no bends its end placed in a floor drain and there is no resistance to the flow of the discharged water 11 The transformer supplied is rated for 120 V power supply Do not connect it to an installation supplied with another voltage 12 Do not set the humidity level higher than normally recommended or condensation damage could occur Safety Warnings 1 Please beware of sharp edges when yo...

Страница 3: ...th a marker line Make a starting hole and cut a rectangular opening that will correspond to the back opening of the humidifier 7 3 4 x 6 1 2 Install the humidifier in the opening and attach it with the four screws 8 x 3 4 The ribs around the humidifier back opening must fit into the rectangular opening in the duct Check that the humidifier body is level from side to side and from back to front The...

Страница 4: ...at is closest to the motor and mark it on the bottom of the pan Carefully make the appropriate round opening by knocking it with a flat screwdriver and a hammer The drain mechanism is factory assembled to be installed on the right side of the pan If the motor is on the right side then no change is necessary If the knockout hole is not big enough to receive the drain mechanism enlarge it a little b...

Страница 5: ... Fig 13 Slip the brass compression nut 13 9 onto the plastic tubing then the nylon sleeve 13 7 with its most tapered end towards the end of tubing Fit the second brass insert 13 8 1 2 long supplied with the brass valve into the end of tubing Push the tubing fully into the supply valve Then tighten the brass compression nut with a small wrench NOTE The brass sleeve 13 6 supplied with the brass valv...

Страница 6: ...istat should be followed by a period of 24 hours to allow the general humidity level to stabilize in the house If your house remains unoccupied during the winter season adjust the humidistat to a lower set point to prevent condensation 20 Humidifier maintenance tips Do not stop nor rotate the drum manually Do not remove the drum when it is rotating as it may cause permanent damage to the motor Che...

Страница 7: ...ess steel hex nut 10 32 Drain kit Drain mechanism Rubber O Ring 0 375 ID x 0 500 OD x 0 070 Plastic hexagonal nut 7 16 24 Drain plastic tube 3 16 ID x 5 16 OD Plunger Spring Rubber O Ring 0 250 ID x 0 437 OD x 0 103 Supply valve Needle valve body top bracket Valve bottom bracket Machine screw 1 4 20 x 1 3 4 Hexagonal nut 1 4 20 Rubber gasket Brass sleeve for copper tubing Nylon sleeve for plastic ...

Страница 8: ...j ...

Страница 9: ...j ...

Страница 10: ...J ...

Страница 11: ...J ...

Страница 12: ...WARNING This diagram is not drawn to actual demensions Please use measurements given to obtain actual size J ...

Страница 13: ...ve not received a satisfactory response notify in writing Hamilton Home Products Inc PO Box 12309 Columbus Ohio 43212 HAMILTON WILL RECEIVE FREIGHT PREPAID ONLY REMOVABLE PARTS OR COMPONENTS OF SUCH DEFECTIVE PRODUCTS 7 This limited one year warranty does not apply to any part or component that is damaged in transit or handling has been subject to abuse neglect or accident has not been installed o...

Отзывы: