Replacing the Sealing Bar Heating Element: 

1.  Peel back the Lower Seal Bar Tape to expose the heating element. 

TIP: 

The screw bosses that secure the heating element are spring loaded to keep tension on the 

heating element, so once you remove a screw the boss will retract slightly into the housing. 
To avoid this and make it easier to reinstall the screws after replacing the heating element, place an object 

such as an ink pen or pencil into the void between the screw boss and the housing to hold the boss in 
place. (pictured below) When securing the new heating element the object inserted into the void can be 
used to help guide the scew boss to the screw. 

 

2.  Using a Phillips head screwdriver, remove the two screws securing the heating element. 
3.  Install the new Seal Bar Heating element 
4.  In not damaged, reinstall the seal bar tape making sure to completely cover the heating element. Replace the 

the tape if it is damaged or no longer adheres. 

 

 

Checking the Vacuum Chamber Interlock switches 

1. 

Turn “OFF” (

0

) the Vacuum Sealer and unplug from the electrical outlet. 

2.  Make sure the unit is completely cool. 
3. Remove the upper housing 
4. Disconnect the interlock quick connect plug 
5. Using a multimeter check for continuity through the interlock switches at the quick connect plug (pictured below). 

You should measure continuity through the switch with the vacuum chamber lid open (approximately .5 Ohms) and 
see an open circuit once the vacuum chamber lid is closed. 

 
 
 
 
 
 
 
 
 

 

 

 