Replacing the Oval Vacuum Chamber Seals: 

1. 

Turn “OFF” (

0

) the Vacuum Sealer and unplug from the electrical outlet. 

2. Make sure the unit is completely cool. 
3. Open the Vacuum chamber lid. 
4. Pull the Oval Vacuum Chamber Seal out from its seating channel on the underside of the Vacuum 

chamber lid. 

5. Place the new seal into the seating channel then firmly compress the seal against itself as you press the 

seal into the channel of the Vacuum Chamber lid. 

6. Repeat process for the Vacuum Chamber Lower Seal 

 

 

Replacing the Lower(15mm) Seal Bar Tape: 

1. 

Turn “OFF” (

0

) the Vacuum Sealer and unplug from the electrical outlet. 

2. Make sure the unit is completely cool. 
3. Open the Vacuum chamber lid. 
4. Lift up and pull to remove the 15 MM Seal Bar Tape covering the Seal Bar Heating Element. 
5. Remove the backing from the new 15 MM Seal Bar Tape. 

Caution: 

Do not allow the tape to contact anything while the adhesive is exposed. 

6. Place the edge of the tape on the left-outermost edge of the vacuum chamber then press down on the 

tape and slide your finger to the right, making sure there are no wrinkles or folds in the Seal Bar Tape. 
Make sure the Seal Bar Heating Element is completely covered by the tape. 

 

 

Replacing the Upper (10 MM) Seal Bar Tape: 

1. 

Turn “OFF” (

0

) the Vacuum Sealer and unplug from the electrical outlet. 

2. Make sure the unit is completely cool. 
3. Open the Vacuum chamber lid. 
4. Lift and pull the 10 MM Seal Bar Tape covering the upper seal. 
5. Remove the backing from the new 10 MM Seal Bar Tape 

Caution: 

Do not allow the tape to contact anything while the adhesive is exposed. 

6. Place the tape on the left edge of the seal then press and slide your finger to the right making sure 

there are no wrinkles or folds in the Seal Bar Tape. 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 