8
Cooling Time (F.1)
Your vacuum-sealing machine is equipped with a COOLING TIME feature that allows for sealing bar to
cool off while setting a secure seal on the vacuum-seal pouch. It can be adjusted from factory setting of
3.0 seconds up to 9.9 seconds, allowing enough time to set seal in thicker pouches.
Soft Air (F.2)
Your vacuum-sealing machine is equipped with a SOFT AIR feature that allows for entry of air back into
chamber at a slow rate to help prevent damage to pouches. Time can be adjusted from factory setting of
2.0 seconds up to 9.9 seconds.
Change the Soft Air and Cooling Times
Changing Cooling Time
1. In standby mode, display will show “oo.” Press and hold FUNCTION SELECT
button for
3 seconds until “F.1” appears on the display.
2. Press the FUNCTION SELECT
button to view the set time.
3. Press the +/STOP VAC
and –/STOP
buttons to adjust desired time.
4. Press the FUNCTION SELECT
button to confirm time. Display will show “F.1” again.
5. Press and hold FUNCTION SELECT
button for 3 seconds to save cooling time.
6. Unit will return to standby mode and display will show “oo.”
Changing Soft Air
1. In standby mode, display will show “oo.” Press and hold FUNCTION SELECT
button for 3 seconds
until “F.1” appears on the display.
2. Press the +/STOP VAC
button to select “F.2.”
3. Press the FUNCTION SELECT
button to view the set time.
4. Press the +/STOP VAC
and –/STOP
buttons to adjust desired time.
5. Press the FUNCTION SELECT
button to confirm time. Display will show “F.2” again.
6. Press and hold FUNCTION SELECT
button for 3 seconds to save cooling time.
7. Unit will return to standby mode and display will show “oo.”
NOTE: Soft air and cooling times are applied to all programs. Regardless of which program is selected,
the soft air and cooling times are the same.
FEATURE
CODE
UNIT
RANGE
Cooling Time
F.1
Seconds
3.0–9.9
Soft Air Bleeding Time
F.2
Seconds
2.0–9.9