Using Read15 for Remote Buck-Ins on Rolls
The
Two-Point Buck-in
tab is used to make the process of
making the laser parallel (bucked-in) to two reference
points easier. There is a short procedure to follow that
requires measuring the dimensions between the target and
laser. When done with this procedure, the laser will be
“bucked-in” (made parallel to) two points on a surface.
Step 1 – Setup
a.
Select the Target ID to use by using the dropdown menu.
b.
Select a location to place the laser.
c.
Select the
Near
and
Far
reference point locations on the surface to be measured (see Figure 25).
d.
Measure the D1 dimension from the laser’s Pivot Point to the center of the target post on the
Near
reference point.
e.
Measure the D2 dimension from the center of the target post on the
Near
reference point to the center
of the target post on the
Far
reference point.
f.
Enter the two dimensions in the entry boxes and click
Next
.
Figure 25 --
Recommended Buck-in points to measure the flatness of a surface.