I. Function Introduction
1. Time Display: Hour, minute, second, month, date, week,
temperature are displayed in normal condition, of which
year, month, date, hour and minute etc. can all be set
according to necessity. The set range for year is
2000~2099, totaling 100years.
2. Multi-language: ”Week” displayed is 2 letters in abbr
viated form and 5 languages are available for
display: German (D), French (F), English (E),
Spanish (S), Italian (I).
3. Alarm with Snooze: Alarm time can be set with snooze
function
4. Thermometer: Temperature of the location is
automatically measured and displayed with temperature
range of - 9.9°C - 59.9°C . Centigrade (°C) or Fahrenheit
(°F) display is selectable.
5. The radio time signal reception: automatic reception of
RCC and manual reception at 2:00 AM, 3:00 AM and
4:00 AM everyday.
II. Button Disposition
III.Function of Buttons
1. MODE BUTTON: Transfer between TIME mode and
ALARM mode by pressing “MODE” button.
2. SET BUTTON:Under normal TIME and ALARM mode,
press the SET button for 2 seconds to enter
respective set modes.
3. ALARM ON/OFF BUTTON: In ALARM mode, press the
button to start up or close the alarm.
4.
°C/°F
BUTTON: Under TIME or ALARM mode, press the
button to adjust numbers upward or
downward; press the button without release, numbers
are adjusted upward or downward at fast speed. In
normal operating condition, transfer of °C/°F is possible
by pressing the button.
5. MANUAL BUTTON: Under TIME mode, receive RCC radio
signal manually by pressing the button for 2 seconds
and suspend the reception by pressing the button in
receiving
process.
6. SNOOZE BUTTON: Press the button to suspend ongoing
alarm and make it snooze.
7. RESET BUTTON: After battery installation or in case of
any abnormal display, please press the “RESET” button
at back of the clock with sharp-pointed stuff, then time,
date and alarm return to initial numbers. So reset them is
a
necessary.
IV. Operation Instruction
1. Initial Use
Open battery door and install battery.
2. Time Set
• In normal time state, press SET button for 2 seconds to
enter TIME SET MODE
• Press “SET” button again to enter set program cycle and
ready-for-set items fl icker in the following order:
-> Choose Week/language -> 12/24 -> Second -> Hour
-> Minute -> Year -> Month -> Date -> Normal Time
Display
• Flicking items can be adjusted upward with °C/°F
button (“Second” back to zero automatically), press
°C/°F
button without release the number will
automatically increase at fast speed.
• If no button is pressed within 60seconds when adjusting
numbers, the clock will automatically retain the adjusted
numbers and return to normal time display state.
• Week display is automatically adjusted with the change
of
date.
3. Alarm Set
• In normal time display state, press “MODE” button to
enter ALARM MODE; press SET button for 2
seconds to ender ALARM set; repress SET button the
ready-for-set items fl icker in the following order:
-> Hour -> Minute
• Press °C/°F button to adjust numbers upward when in
setting.
• Under ALARM mode and not in SET state, press ALARM
ON/OFF button to turn on/off alarm ; no “ALARM” sign
displayed when alarm off, “ALARM” sign displayed when
alarm
on.
• No button pressed within 60seconds when adjusting
numbers, the clock will retain the adjusted numbers
automatically and return to the normal time display state.
g
Operating Instructions
4. Alarm with snooze
• When alarm time arrives, it alarms for 1min with
“ALARM” sign glimmering; press any button to stop
alarm; press “SNOOZE” button to enter snooze state with
“SNOOZE” sign glimmering,
• Press “SNOOZE” button to suspend the ongoing alarm
with “SNOOZE” sign glimmering and it alarms again
every 5mins; Press “SNOOZE” button again, it will alarm
every 5mins again.
• Alarm for 1min and stop if no button pressed; if any
button except “SNOOZE” is pressed, the snooze
function is immediately stopped.
5. Transfer of temperature °C/°F
In normal operating condition, press °C/°F ALARM/ON
button to transfer °C/°F display
V. Reception of RCC signal
1. Within RCC signal coverage, RCC signal can be
automatically received, time, year, month and date
numbers are automatically adjusted in accordance with
RCC standard time.
2. Automatic reception of RCC signal is possible after the
installation of battery;
3. Manual reception of RCC signal is possible by pressing
MANUAL Button for 2 seconds
4. RCC signal is automatically received every 4 hours per
day. In case of one successful RCC reception, no more
RCC received that day. New RCC reception begins next
day.
5. Time for RCC reception
a) 8mins is possibly needed for RCC reception when the
signal
is
weak.
b) Reception of RCC stops after trying for 4mins when
there’s no RCC signal.
c) 2-3mins is needed to receive RCC when the signal is
strong. sign displayed signifi es the RCC
reception
is
fi
nished.
Other button is effectively pressed only by suspending
the ongoing reception with MANUAL button
VI. Points of attention concerning battery
1. Battery type marked in battery bath is referred to for
battery purchase and quality alkaline dry cell is
preferred. Identify positive pole and negative pole when
in
installation.
2. When LCD display becomes lighter or any abnormal
sound there, change the batteries immediately;
take care mixed use of new and old battery; battery of
different types and brands is forbidden.
3. Take out the battery if unused for long time to come to
avoid any damage to the clock due to possible
leakage of the battery.
00076048bda.indd Abs2:4-Abs2:5
00076048bda.indd Abs2:4-Abs2:5
26.07.2007 9:26:43 Uhr