11
HAMA_DP2_UM-20151116-EN
4 COMMISSIONING
EN
4 COMMISSIONING
Introduction
Check the HAMA Duo-Power 2.0 for possible transport damage at the time of delivery. Report
transport damage to the carrier and your supplier immediately.
Inspection of hopper
Prior to first use, check whether the hopper is completely clean. During transport or storage,
items such as wood, coarse gravel, stones or nails could have landed in the machine. These items
could cause serious damage to the machine.
Set-up
Make sure that the machine is level prior to use.
Connection to a power supply
The HAMA Duo-Power 2.0 must be connected to a 230 V wall socket with earth connection and
must be fused for 16 A.
If no wall socket is available in the immediate area, no more than one fully extended extension
reel or extension cord with an earth connection and a minimum core thickness of 2.5 mm
2
may be
used.
Extension cords that are too long and lightweight can cause
undervoltage, causing the electric motor to burn out. HAMA advises
using extension cords with a minimum core thickness of 2.5 mm
2
.
The HAMA Duo-Power 2.0 can generate an operating pressure of 140
bar. Leaks due to damage to hoses and couplings can lead to physical
injury.
Never connect the HAMA Duo-Power 2.0 in combination with the
HAMA H455 compressor to the same fuse group. Both machines on
the same fuse group will cause an overload!
Extension reels must be fully extended in order to prevent fire.
If the HAMA Duo-Power 2.0 is used in combination with the HAMA
H455 compressor or another equivalent compressor, each machine
must be connected to a separate fuse group of 16 A.
ATTENTION
ATTENTION