Functions
7100.006434_Bus description_PSD4xx_IO_J_ENG
56
2022-09-13
3.12.
Aborted run when the master fails
If the connection to the master is interrupted during a positioning run, the master cannot abort a
run that is already underway.
In this case, there are two possible responses:
1) If a positioning run is in progress, the drive should
complete this positioning run as
planned
. It should then not start any new positioning run until a connection has been re-
established.
This response is activated when ISDU
162 (“Communication timeout”) is set to 0.
2) If a positioning run is in progress, the drive should
abort this positioning run
. It should then
not start any new positioning run until a connection has been re-established.
This response is activated when ISDU
162 (“Communication timeout”) is set to a
value > 0. The value specifies the time (in ms) within which a new master telegram must
be received in order to maintain the connection.