Description of IO-Link
7100.006434_Bus description_PSD4xx_IO_J_ENG
34
2022-09-13
Bit
13
Toggle bit
Always when a command byte is received, the drive writes the value of this bit in
status byte bit 2.
The control unit can recognize when new process data are processed by the
drive.
Bit
14
Error Acknowledge:
with a 0
1 edge of this bit, the error bits 5, 10, 11, 12 and 13 in the status byte
are acknowledged (available from firmware V19).
Bit
15
Reserved
must be set to 0