Description of IO-Link
7100.006434_Bus description_PSD4xx_IO_J_ENG
23
2022-09-13
Designation
ISDU
no.
Function
Range of
values
Back
up?
Delivery
state
R/W
“Other” parameter group
Free register
169
Freely-usable register
± 31 bit
Yes
0
R/W
UMot limit
179
Voltage limit for bit “Motor
power present” given in
increments of 0.1
V
180 ...
240
16 bit
Yes
185
R/W
Temperature
limit
180
Upper temperature limit in °C
10 ... 80
16 bit
Yes
80
R/W
Modulo
mode
184
**)
0
Modulo function inactive
1
Run to larger values
2
Run to smaller values
3
Shortest way
4
Run to larger values
with blocking zone
5
Run to smaller values
with blocking zone
0
… 5
8 bit
Yes
0
R/W
Upper
modulo
position
185
**)
Highest position of the modulo
range
When this position is reached,
the actual position jumps to the
value [lower modulo position].
(value in steps)
± 31 bit
Yes
3600
R/W
Lower
modulo
position
186
**)
Lowest position of the modulo
range
If the actual position falls below
this value, it jumps to the value
[Upper modulo position - 1].
(value in steps)
± 31 bit
Yes
0
R/W
**) The ISDUs 184-186 are available from firmware V19. For the variants with the option
“Modulo
function
” (i.e. variants with the feature “Software modules” = “M” or “Z”), the modulo function is
configured with these ISDUs. For the variants without modulo function (i.e. variants with the
feature
“software modules” = “1”, “S” or “P”) only the default value can be written, other values
are rejected.