PSx3xxDN Instruction Manual
7
Round plug for CAN bus:
Round socket for CAN bus:
(external top view)
(external top view)
1
shield
2
+24V control module
3
GND
4
CAN_H
5
CAN_L
To prevent the ingression of fluids into the PSW-housing during
cooldown, use a special cable with an airtube for pressure
balancing of your PSW.
Electrical grounding
Next to the connecting plugs there is a M4 stud bolt. It is recommended to connect
the positioning system with a cable as short as possible to the machine base. The
minimum wire cross section therefor is 1.5mm².
2.4
Setting the device address and baud rate
Removing the protective cap provides access to two rotary switches for setting the
device address at the bus and a 2-pin sliding switch for setting the baud rate.
The rotary switches indicate the tens and ones places of the address selected. If the
switches are resting in positions between 64 and 99, the address is set using
DeviceNet (PSE object; class 100, instance 1, attribute 38; starting from software
version 147).
The delivery setting is 99, the PSx3xxDN reports to the bus with the address 63.
If the switches have been used to set the address (i.e. the switch setting is < 64), this
value cannot be changed via DeviceNet.
The yellow LED represents the state of the motor supply voltage, the red and green
LEDs represent the DeviceNet state.