SCWT4A-CB-Q*1E SCWT8A-CB-Q*1E SCWT14A-CB-Q*1E
97037C (Rev. A - 4/98)
PAGE 3
PUSH BUTTON VALVE ADJUSTMENT
FIG. 4
1
5
24
26
25
23,27,28
CORRECT STREAM HEIGHT
FIG. 3
22111C
22112C
22113C
30980C
31386C
31428C
50787C
70606C
70607C
70640C
70659C
70683C
70793C
22588C
1
2
3
4
5
6
7
8
9
10
11
12
13
NS
PART. NO.
DESCRIPTION
ITEM NO.
HOT TANK PARTS LIST
Heater Clamping Bracket
Heater Clamping Bracket (thrd)
Retaining Bracket
Heater Element & Jacket
Tank & Tube Assy
Hot Control Assy
Washer-Spacer
Drain Plug
Screw 1/4-20 x 3.00" HSHC
Screw #8-18 x 5/16" HHTC
Belleville Washer
1/4 Union
1/4 Elbow
Hot Tank Mounting Bracket
SERVICING THE HOT CONTROL AND FUSE ASSEMBLY
1. A temperature sensing non-resetable fuse in the wire is located approximately 3" (76mm) from the thermostat.
The fuse is located under the retaining bracket (Item 3) in the groove on the heater element jacket (Item 4).
2. The thermostat must be used with a washer-spacer (Item 7) and be centered in the heater element jacket for
proper temperature control. Locate the heater element jacket about 3/4" (19mm) above the bottom of the tank.
3. The heater element jacket must be fastened
VERY TIGHTLY
to the tank (45+/-10 inch/lbs. of torque on the mounting
screw Item 9). Failure to
TIGHTEN
heater element jacket may cause rapid failure of the fuse assembly.
10
3
6
7
9
11
1
2
8
13
4
5
12
ADJUST THIS SCREW TO ELIMINATE VALVE
LEVER "FREE PLAY" OR CONTINUOUS FLOW
FROM BUBBLER
STREAM HEIGHT