PUSH BUTTON VALVE ADJUSTMENT

FIG. 4

1

5

24

26

25

23,27,28

CORRECT STREAM HEIGHT

FIG. 3

22111C

22112C

22113C

30980C

31386C

31428C

50787C

70606C

70607C

70640C

70659C

70683C

70793C

22588C

1

2

3

4

5

6

7

8

9

10

11

12

13

NS

PART. NO.

DESCRIPTION

ITEM NO.

HOT TANK PARTS LIST

Heater Clamping Bracket

Heater Clamping Bracket (thrd)

Retaining Bracket

Heater Element & Jacket

Tank & Tube Assy

Hot Control Assy

Washer-Spacer

Drain Plug

Screw 1/4-20 x 3.00" HSHC

Screw #8-18 x 5/16" HHTC

Belleville Washer

1/4 Union

1/4 Elbow

Hot Tank Mounting Bracket

SERVICING THE HOT CONTROL AND FUSE ASSEMBLY

1.  A temperature sensing non-resetable fuse in the wire is located approximately 3" (76mm) from the thermostat.

    The fuse is located under the retaining bracket (Item 3) in the groove on the heater element jacket (Item 4).

2. The thermostat must be used with a washer-spacer (Item 7) and be centered in the heater element jacket for

    proper temperature control.  Locate the heater element jacket about 3/4" (19mm) above the bottom of the tank.

3. The heater element jacket must be fastened 

VERY TIGHTLY

 to the tank (45+/-10 inch/lbs. of torque on the mounting

     screw Item 9).  Failure to 

TIGHTEN

 heater element jacket may cause rapid failure of the fuse assembly.

10

3

6

7

9

11

1

2

8

13

4

5

12

ADJUST THIS SCREW TO ELIMINATE VALVE

LEVER "FREE PLAY" OR CONTINUOUS FLOW

FROM BUBBLER

STREAM HEIGHT

ADJUSTMENT SCREW