![Halsey Taylor HydroBoost HTHB-HAC Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/halsey-taylor/hydroboost-hthb-hac/hydroboost-hthb-hac_installation-and-use-manual_3553591009.webp)
Page 9
1000004727 (Rev. A - 09/18)
HAC-HB*1C HAC-HB-NF-*1C
Fig. 5
RE-PLUMBING TWO LEVEL STATION WATER CIRCUITS (WITH FILTER)
HAC TWO LEVEL Hydroboost PLUMBING BOTTLE FILLER ON LH UNIT (SEE NOTE 2)
STANDARD HAC TWO LEVEL PLUMBING WITHOUT BOTTLE FILLER
TO BUBBLER
TO BUBBLER
REGULATOR
IN-LINE STRAINER
REGULATOR
FILTER
L.H. DUMMY UNIT
R.H. REFRIGERATED UNIT
EVAPORATOR
OUTLET
EVAPORATOR
EVAPORATOR
INLET
L.H. DUMMY UNIT
R.H. REFRIGERATED UNIT
EVAPORATOR
EVAPORATOR
OUTLET
EVAPORATOR
INLET
REGULATOR
TEE
TO BUBBLER
TO BOTTLE
FILLER
TO BUBBLER
REGULATOR
HAC TWO LEVEL Hydroboost PLUMBING BOTTLE FILLER ON RH UNIT (SEE NOTE 3)
TO BUBBLER
FILTER
TO BOTTLE
FILLER
TEE
EVAPORATOR
INLET
EVAPORATOR
OUTLET
EVAPORATOR
REGULATOR
L.H. DUMMY UNIT
R.H. REFRIGERATED UNIT
CAUTION:
• This procedure MUST be performed on ALL TWO LEVEL HALSEY TAYLOR WATER COOLERS
or the bottle filling unit
WILL NOT perform properly!
• When disconnecting water lines use a container to catch any water running out of the lines.
1) Connect Water Supply:
•
In the left hand unit,connect the Filter outlet using 1/4” poly tubing to the Evaporator 1/4” copper inlet using the supplied 1/4”
quick connect fitting.
2) Add water supply to Bottle Filler to be located on LH unit:
•
In the left hand unit, cut the Evaporator outlet 1/4” poly tubing approx. 5” from the access opening between the units, insert
the 1/4” Tee fitting between the two pieces and connect 3/8” water line to tee.
3) Add water supply to Bottle Filler to be located on RH unit:
•
In the right hand unit, cut the Evaporator outlet 1/4” poly tubing approx. 2” from the access opening between the units, insert
the 1/4” Tee fitting between the two pieces and connect 3/8” water line to tee.