Page 13

1000004727  (Rev. A - 09/18)

HAC-HB*1C     HAC-HB-NF-*1C

VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the unit will  

    need to be shut down and restarted. The chiller (if present) does 

    not need to be shut down and restarted.

2) The units lower panel must be open to access the power cord and 

    wall outlet.

3) Shut down the unit by unplugging the power cord from the wall 

    outlet. 

4)  Restart the unit by plugging the power cord back into the wall 

    outlet.

5) Upon start up, the bottle count display will show the software 

    designation of BF11 or BF12.

ACCESSING THE PROGRAMMING BUTTON

1)   To access the program button, remove the top cover of the bottle- 

  filler. Remove the two (2) screws holding top cover to bottle-filler 

  with a 5/32” allen wrench. Remove top cover. Do not discard

  mounting screws, they will be needed to reinstall the top cover after  

  programming operations are completed. The programming button  

  is located at the top right side of the unit on the control board.  

 

NOTE: When applicable, there is also an alternate reset button  

  located on the lower part of the water cooler. After removing

  the bottom cover, the reset button will be located on the left 

  side of the cooler, mounted on the side panel support.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.

2) Depress the program button for approximately 2 seconds until 

    the display changes then release. The display will change and 

    scroll through two messages:

       “RST FLTR” – Reset Filter Monitor

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

3) When the display changes to “RST FLTR”, depress the button 

    again. The display will change to show “FLTR =”. Depress the

    button again and the display will show “FLTR =0”

4) The Green LED should be illuminated indicating that the visual 

    filter monitor has been reset.

 SETTING RANGE OF THE IR SENSOR WHERE APPLICABLE

1) Depress the program button for approximately 2 seconds until 

    the display changes then release. The display will change and 

    scroll through two messages:

       “RST FLTR” – Reset Filter Status LED

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button 

    again. The display will change to show

      “RNG SET” -  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

      “FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

3)  When display shows “RNG SET” push program button once the 

    display will show current value (can be 1 – 10) e.g. “RNG = 3”.

4) Once display shows current value push the program button to 

    scroll through value of 1 – 10. Select the desired range setting, 

  "1" being closest to sensor and "10" being farthest away.

5) Once range is selected allow approximately 4 seconds to pass and

    then the display will go back to bottle counter and be in run mode.

6)  Test bottle filler by placing bottle or hand in front of sensor to 

    make sure water is dispensed.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll 

    through two messages:

       “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

Continued from below:

2)  When the display changes to “SETTINGS”, depress the button again.  

      The display will change to show

       “RNG SET” -  Range set for IR sensor.

       “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       “FLT SIZE” - Select filter capacity

       “RST BCNT” - Reset bottle count

3)  When display shows “UNIT TYPE” push program button once the

    display will show current value.  Can be REFRIG or NON-RFRG

4) Push button once to change value. Once value is    selected the display 

    will show the new value.  (Can be REFRIG or NON-RFRG)  

     

“REFRIG“ - stands for refrigerated product. In this setting the flow rate is 

    estimated at 1.0 gallon per minute.

     “NON-RFRG“ - stands for nonrefrigerated product. In this setting the  

    flow rate is estimated at 1.5 gallons per minute.  Both “REFRIG“ and 

    “NON-RFRG“ simulate   

1 bottle equal to 20 oz.

5)  Allow approximately 4 seconds to pass and the display will return to    

    bottle counter and be in run mode.

    

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll

    through two messages:

      “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll through  

    the two messages above for three cycles and then default back to bottle 

    count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button again. 

     The display will change to show:

      “RNG SET”-  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       

“FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

    If the button is not pushed again the display will scroll through the four 

    messages above for three cycles and return to run mode.

3)  When display shows “RST BCNT” push program button once the

    display will show current value, e.g. “0033183”.

4) Once display shows current value push the program button once more 

    to reset back to 0. The display will show BTLCT = 0 for approximately 2 

    seconds and then return to run mode showing 00000000 bottles. 

 

NOTE: Once the bottle count is reset to zero there is no way to 

  return to the previous bottle count.

5)  Testing the bottle counter:

     REFRIG units: Place bottle or hand in front of sensor for approximately 

  9 seconds to see bottle counter count 00000001, 

     (This is based on filling a 20 oz. bottle).

     NON-RFRG units: Place bottle or hand in front of sensor for 

  approximately 6 seconds to see bottle counter count 00000001,

     (This is based on filling a 20 oz bottle).

    

 SETTING FILTER CAPACITY

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll through 

    two messages:

      “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll through 

    the two messages above for three cycles and then default back to bottle 

    count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button again. 

     The display will change to show:

      “RNG SET“-  Range set for IR sensor.

      “UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

      

 “FLT SIZE” - Select filter capacity

      “RST BCNT“ - Reset bottle count

    If the button is not pushed again the display will scroll through the four 

    messages above for three cycles and return to run mode.

3)  When display shows “FLT SIZE” push program button once. The display 

     will show current value. Can be 3000GAL or 6000GAL.

4)  Push program button again to display the desired “FLT SIZE”. 

5)  Allow approximately 4 seconds to pass and the display will return to 

     bottle counter and be in run mode.

BF11 - BF12 PROGRAM

SETTING THE CONTROL BOARD

Содержание HydroBoost HTHB-HAC

Страница 1: ...CTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEE...

Страница 2: ...Before proceeding Disconnect electrical power supplying the water cooler Switch circuit breaker OFF or remove fuse Unplug water cooler power cord from electrical outlet Shut off water supply NOTE On T...

Страница 3: ...emove the protective covering from the basin Reinstall the drain elbow drain plug and strainer plate on to the new basin Attach the new drain hardware onto the new basin Exchange Bubbler hardware WATE...

Страница 4: ...ck the o rings Loosen the locknut and push tube end past both o rings to a positive stop in the filter head recess approx 1 Locknut may have to be backed out a little more Screw the locknut hand tight...

Страница 5: ...filter and the water inlet using the supplied 3 8 x3 8 union connector Discard in line strainer Single Level Models Two Level Models HWF3000 WATERSENTRY PLUS FILTER INSTALLATION With Filter Fig 1 Sing...

Страница 6: ...into insulation Insert 1 4 poly tube into the Regulator Outlet unmarked Opposite end of 1 4 poly tube will be inserted later into the Bubbler RE PLUMBING SINGLE STATION WATER CIRCUITS NON FILTER CAUTI...

Страница 7: ...ut the Evaporator Outlet 1 4 poly tubing 6 from the Evaporator Outlet and insert the 1 4 Tee fitting between the two pieces Connect Bottle Filler supply line to Tee fitting Remove 1 4 poly tubing from...

Страница 8: ...TOR L H DUMMY UNIT R H REFRIGERATED UNIT HAC TWO LEVEL Hydroboost PLUMBING BOTTLE FILLER ON RH SIDE SEE NOTE 2 1 Add water supply to Bottle Filler to be located on LH unit In the left hand unit cut th...

Страница 9: ...D UNIT CAUTION This procedure MUST be performed on ALL TWO LEVEL HALSEY TAYLOR WATER COOLERS or the bottle filling unit WILL NOT perform properly When disconnecting water lines use a container to catc...

Страница 10: ...w Basin Assembly Reposition Basin Assembly Basin with Drain and Bubbler hardware back onto the cooler Reattach drain line to P trap and tighten 3 Fasten Basin Assembly in place Insert and retighten th...

Страница 11: ...ound boss in gasket fits in hole of basin 9 Once Bottle Filler is installed on wall plate tabs water line and power cord are installed properly push top of Bottle Filler toward wall and line up top co...

Страница 12: ...Page 12 1000004727 Rev A 09 18 HAC HB 1C HAC HB NF 1C BOTTLE FILLER GASKET Fig 9 Fig 10...

Страница 13: ...ill scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button...

Страница 14: ...Mtg Brkt John Guest Fittings Screws 1 2 3 55898C 98926C 0000000746 DESCRIPTION PART NO FILTER PARTS LIST See Fig 12 DESCRIPTION 98543C 98544C 1000004573 98546C 98547C 98549C 98668C 98669C 98670C 0000...

Отзывы: