VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the unit will  

    need to be shut down and restarted. The chiller (if present) does 

    not need to be shut down and restarted.

2) The units lower panel must be open to access the power cord and 

    wall outlet.

3) Shut down the unit by unplugging the power cord from the wall 

    outlet. 

4)  Restart the unit by plugging the power cord back into the wall 

    outlet.

5) Upon start up, the bottle count display will show the software 

    designation of BF11. 

6) Reference the BF11 instructions for setting the control board.

ACCESSING THE PROGRAMMING BUTTON

1)   To access the program button 

remove the top cover of the bottle-

    filler. Remove the two (2) screws holding top cover to bottle-

    filler with a 5/32” allen wrench.  Remove top cover. Do not discard 

    mounting screws, they will be needed to reinstall the top cove

 

after 

    programming operations are completed. The programming button 

    is located at the top right side of the unit on the control board.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.

2) Depress the program button for approximately 2 seconds until 

    the display changes then release. The display will change and 

    scroll through two messages:

       “RST FLTR” – Reset Filter Monitor

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

3) When the display changes to “RST FLTR”, depress the button 

    again. The display will change to show “FLTR =”. Depress the

    button again and the display will show “FLTR =0”

4) The Green LED should be illuminated indicating that the visual 

    filter monitor has been reset.

 SETTING RANGE OF THE IR SENSOR

1) Depress the program button for approximately 2 seconds until 

    the display changes then release. The display will change and 

    scroll through two messages:

       “RST FLTR” – Reset Filter Status LED

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button 

    again. The display will change to show

      “RNG SET” -  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

      “FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

3)  When display shows “RNG SET” push program button once the 

    display will show current value (can be 1 – 10) e.g. “RNG = 3”.

4) Once display shows current value push the program button to 

    scroll through value of 1 – 10. Select the desired range setting.

5) Once range is selected allow approximately 4 seconds to pass and

    then the display will go back to bottle counter and be in run mode.

6)  Test bottle filler by placing bottle or hand in front of sensor to 

    make sure water is dispensed.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll 

    through two messages:

       “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

Continued from below:

2)  When the display changes to “SETTINGS”, depress the button again.  

      The display will change to show

       “RNG SET” -  Range set for IR sensor.

       “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       “FLT SIZE” - Select filter capacity

       “RST BCNT” - Reset bottle count

3)  When display shows “UNIT TYPE” push program button once the

    display will show current value.  Can be REFRIG or NON-RFRG

4) Push button once to change value. Once value is    selected the display 

    will show the new value.  (Can be REFRIG or NON-RFRG)  

     

“REFRIG“ - stands for refrigerated product. In this setting the flow rate is 

    estimated at 1.0 gallon per minute.

     “NON-RFRG“ - stands for nonrefrigerated product. In this setting the  

    flow rate is estimated at 1.5 gallons per minute.  Both “REFRIG“ and 

    “NON-RFRG“ simulate   1 bottle equal to 20 oz.

5)  

Allow approximately 4 seconds to pass and the display will return to    

    bottle counter and be in run mode.

    

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll

    through two messages:

      “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll through  

    the two messages above for three cycles and then default back to bottle 

    count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button again. 

     The display will change to show:

      “RNG SET”-  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       

“FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

    If the button is not pushed again the display will scroll through the four 

    messages above for three cycles and return to run mode.

3)  When display shows “RST BCNT” push program button once the

    display will show current value e.g. “0033183”.

4) Once display shows current value push the program button once more 

    to reset back to 0. The display will show BTLCT = 0 for approximately 2 

    seconds and then return to run mode showing 00000000 bottles.

5)  Testing the bottle counter:

     REFRIG units: Place bottle or hand in front of sensor for 9.4 seconds to 

     see bottle counter count 00000001, 

     (This is based on filling a 20 oz. bottle).

     NON-RFRG units: Place bottle or hand in front of sensor for 6.25

     seconds to see bottle counter count 00000001,

     (This is based on filling a 20 oz bottle).

    

 SETTING FILTER CAPACITY

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll through 

    two messages:

      “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll through 

    the two messages above for three cycles and then default back to bottle 

    count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button again. 

     The display will change to show:

      “RNG SET“-  Range set for IR sensor.

      “UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

      

 “FLT SIZE” - Select filter capacity

      “RST BCNT“ - Reset bottle count

    If the button is not pushed again the display will scroll through the four 

    messages above for three cycles and return to run mode.

3)  When display shows “FLT SIZE” push program button once. The display 

     will show current value. Can be 3000GAL or 6000GAL.

4)  Push program button again to display the desired “FLT SIZE”. 

5)  Allow approximately 4 seconds to pass and the display will return to 

     bottle counter and be in run mode.

BF11 PROGRAM

SETTING THE CONTROL BOARD

Содержание HVRGRN8WS 1C Series

Страница 1: ...1 MANUAL DEL PROPIETARIO HALSEY TAYLOR MANUEL DE L UTILISATION HALSEY TAYLOR Hydroboost Bottle Filling Station and Cooler Owners Manual Estaci n de llenado de botella Hydroboost y enfriador Station d...

Страница 2: ...1 14 Page 2 Fig 1 24 13 14 22 29 14 6 19 25 17 14 30 5 12 17 14 22 4 See Fig 4 See Fig 3 33 20 31 23 3 34 Pictured is unit only without bottle filler Uses HFC 134A refrigerant Usa refrigerante HFC 134...

Страница 3: ...N BY MAINTAINING 6 152 mm MIN CLEARANCE FROM CABINET LOUVERS TO WALL ASEGURE UNA VENTILACI N ADECUADA MANTENIENDO UN ESPACIO E 6 152 mm M N DE HOLGURA ENTRE LA REJILLA DE VENTILACI N DEL MUEBLE Y LA P...

Страница 4: ...the trap and tighten securely INSTALACI N DEL ENFRIADOR DE AGUA 4 Suspenda el enfriador en el fijador de suspensi n Aseg rese que el fijador de suspensi n calce correctamente en las ranuras de la part...

Страница 5: ...HVRGRN8WS 1C HVRGRN8WSNF 1C 1000001739 Rev B 11 14 Page 5 Fig 4 28 2 9 26 27 8 7 1 PUSH BUTTON MECHANISM MECANISMO DE BARRA DE EMPUJE M CANISME DU BOUTON POUSSOIR 10 29 11 10...

Страница 6: ...basin place a towel or soft cloth over the entire basin when working above it 10 With the power cord wire s and waterline through hole on top of water cooler place Bottle Filler on the three 3 angled...

Страница 7: ...d then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for I...

Страница 8: ...HVRGRN8WS 1C HVRGRN8WSNF 1C 1000001739 Rev B 11 14 Page 8 BOTTLE FILLING UNIT WALL MOUNTING PLATE Fig 10 Fig 9 22 16 21 21 4...

Страница 9: ...tuerca para sellar Diagrama de cableado de 115 voltios Sch ma de c blage de 115 volts DESCRIPCI N ITEM NO Filter Assy 3000 Gal Kit Filter Head Fitting includes John Guest Fitting 3 8 Elbow Fitting Ass...

Страница 10: ...ee Filter Table PART NO Panel Bottom Dispenser Button Push Hanger Bracket Basin Stainless Steel Power Cord Compressor Serv Pak EM 65 HHC Half Nut Regulator Sleeve Push Button Washer Kit Regulator Spri...

Отзывы: