background image

PAGE 5

98402C (Rev. C - 02/18)

EHWM14FP*A     EHWM17FP*A

FIG. 4

EHWM17FP

ROUGH-IN DRA

WINGS

1. W

all should already be framed for the fountain using dimensions shown in Fig. 3.

 Shown dimensions pertain to installation location. 

   

These dimensions are required for compliance with 

ANSI Standard 

A1

17.1. and 

ADA

 (Framing shown for reference only).

2. Remove bottom cover from fountain and save the screws. 3. Install the fountain 

using bolts and washers (not provided). 

Tighten securely

.

4. 

Attach drain tube

 to fountain and cut to required length using the freeze resistant box as a guide.

5. Install freeze-resistant box 

- see box instructions.

6. Replace 

bottom cover

.

* Adult 

ADA

 Requirement

**24" for Child 

ADA, adjust other

measurements accordingly

.

13

 3

/8

"

34

0m

m

12

 3

/8

"

31

4m

m

16

 7

/8

"

42

8m

m

19

 3

/8

"

49

2m

m

22

 7

/8

"

58

1m

m

28

"

71

1m

m

34

"

86

3m

m

5/

8"

91

m

m

5/

8"

66

m

m

12

"

30

5m

m

M

ax

. W

al

l

Th

ic

kn

es

s

33

"

83

8m

m

Or

ifi

ce

 H

ei

gh

t

39

"

99

0m

m

Or

ifi

ce

 H

ei

gh

t

5/

8"

16

m

m

18

"

45

7m

m

18

 3

/4

"

47

7m

m

*

Fi

ni

sh

ed

 F

lo

or

27

"

68

6m

m

3/

8"

11

1m

m

13

/1

6"

97

m

m

12

 1

/8

"

30

9m

m

5/

8"

16

8m

m

38

 1

/2

"

97

8m

m

24

 1

/2

"

62

2m

m

20

 3

/8

"

51

8m

m

33

"

83

8m

m

*

12

"

30

5m

m

M

ax

. W

al

l

Th

ic

kn

es

s

Содержание EHWM14FP A Series

Страница 1: ...LKFRB1thatareinstalledonaninteriorheatedwall Theinteriorspace must maintain a minimium temperature of 50 F 10 C Refer to the Freeze Resistant Package for the rough in dimensions for installation INSTA...

Страница 2: ...m 16 406mm 26 660mm 6 152mm 1 2 13mm 5 1 4 133mm 5 1 4 133mm 24 11 16 628mm 28 711mm 29 1 2 749mm WALL PLATE ASSEMBLY A B D C Finished Floor E 1 2 13mm LEGEND A 1 3 4 DIA 44mm HOLE FOR WASTE LINE B 7...

Страница 3: ...lready be framed for the fountain using dimensions shown in Fig 1 Shown dimensions pertain to installation location These dimensions are required for compliance with ANSI Standard A117 1 and ADA Frami...

Страница 4: ...ATER SUPPLY TUBE C 7 8 DIA 22mm HOLE FOR OPERATING CABLE D 1 4 DIA 6mm HOLES FOR MOUNTING PLATE TO WALL E 3 8 DIA 10mm HOLES FOR MOUNTING PLATE TO WALL Finished Floor 28 711mm 29 1 2 749mm 43 3 4 1111...

Страница 5: ...ded Tighten securely 4 Attach drain tube to fountain and cut to required length using the freeze resistant box as a guide 5 Install freeze resistant box see box instructions 6 Replace bottom cover Adu...

Страница 6: ...PAGE 6 98402C Rev c 02 18 EHWM14FP A EHWM17FP A FIG 8 FIG 5 FIG 6 See Fig 6 See Fig 5 FIG 7 CABLE SHEATH ADJUSTMENT To Increase Free Play To Reduce Free Play...

Страница 7: ...elieve water pressure push in on dark gray collar while pulling out on the tubing See Figure 10 5 Connect drain and water supply lines to the freeze resistant fountain Refer to Figure 1 or Figure 3 fo...

Страница 8: ...VR BUBBLER ASSEMBLY PUSH BUTTON SLEEVE PUSH BUTTON GUIDE DRAIN PLUG 1 1 2 KIT DRAIN TAILPIPE SNAP BUSHING BUMPER REG VALVE ASSY FOUNTAIN ARM PUSH BUTTON EXTENSION POLY TUBING CUT TO LENGTH DRAIN GASKE...

Отзывы: