PAGE 12
97738C (Rev. D - 4/04)
4715FR-FTN
The Following Items are included with
the 4715FR Fountain
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
100147140560
100322740560
101570540560
15013C
15014C
110544942550
110868642550
160270508640
170705042830
28091C
40045C
400942308640
45403C
45829C
45842C
45663C
55913C
600985451640
66346C
70683C
75534C
75588C
75589C
75520C
75565C
75596C
56092C
56123C
75539C
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
NS
NS
NS
NS
NS
NS
Drain Gasket
Gasket
Drain Gasket
Bubbler Tube Assy.
Retaining Nut
Set Screw #8-32 x .125
Socket Head Screw #10-24 x .75
Strainer Plate
Basin
Nameplate Insert
Hex Nut 1-5/16"
Bubbler
Push Button Actuator
Fountain Body
Access Panel
Push Button Sleeve
Drain Adapter
Drain Plug Assy.
Drain Tube
Union 1/4"
Pinned Torx Screw #10-24
Slip Joint Nut 1-1/4"
Gasket
Bit - Pinned Torx T-25
Fitting - Double Male Connector
Paint Touch-up (Pen)
Poly Tubing - 1/4"
(Cut To Length) - To Bubbler
Poly Tubing - 1/8"
(Cut To Length) - To Actuator
Allen Wrench
ITEM NO.
PART NO.
PARTS LIST
DESCRIPTION
Touch-up Paint
For minor scratches a Touch-up Paint Stick is available. For repairing large defects,
off-the-shelf aerosol paint from your local hardware store can be used. Listed are two
suggested brandnames.
Brandname: X-O
Brandname: Ace Hardware
XO-11 Hunter Green
Rust Stop / Machine & Implement International Green
Trouble Shooting
Insufficient Bubbler Flow:
Check that the shut-off valve is wide open. Verify
minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean
rubber orifice in flow control located below frost line in bushing between barb fitting and valve.
No Flow:
Check for leaks in the air tubing going from the push button to the valve. Make
sure the air tubing compression nut is hand tight. Disconnect air tube from push button.
Place finger over air outlet. Push button to test diaphragm. Tighten diaphragm cap screws.
Replace diaphragm if necessary.
Continued Insufficient or Varied Height of Bubbler Flow:
Replace flow control.
Check for kinks in the tubing.
Remove the cleanout plug from the PVC column. Remove the valve assembly from the
PVC column by carefully pulling up on the strap and connecting tubing at the same time.
Pressure test the valve assembly for leaks. Check stream height from the bubbler. Stream
height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust the screw
on the regulator (Item 11, Page 10, Fig. 4). Clockwise adjustment will raise stream and
counter-clockwise adjustment will lower stream. For best adjustment stream height should be
approx. 1-1/2" (38mm) above the bubbler guard. Replace the valve into the PVC column.
Make sure the supply hose coils into the bottom of the PVC column without any kinks and
double check that the valve is positioned fully at the bottom of the PVC column. Cap the
PVC column.
Continuous Bubbler Flow:
Insure that push button is not obstructed and springs back
to normal position. Remove four screws which secure plastic diaphragm block to valve body.
Pull plastic and rubber diaphragm assembly out of valve body. Locate tiny hole in rubber
diaphragm just under lip of plastic part. Clean debris from this hole. Inspect valve seat for
grooves. If valve seat was OK and diaphragm hole was free from debris, inspect rubber
button located at center of floating steel disc in valve diaphragm block assembly. If button is
worn, turn disc over or replace it. If diaphragm and seats are in good condition, stretch spring
slightly. Spring is located behind floating stainless steel plate. Insure that air bleed port on
valve plastic block assembly is not plugged.
Included with
SanitaryFR1
Valve
FIG. 9
30
31
38
32
39
36
34
40
37
21
18
20
19
26
25
35
24
19
23, 29
30
33
27
28
22
30