background image

PAGE 1

4410FR-FTN

97733C (Rev. G - 04/04)

Halsey Taylor Owners Manual

4410 Freeze Resistant Tubular Fountain

Halsey Taylor Fountains are among the easiest to install Fountains on the market today. To

assure you install these models easily and correctly, PLEASE READ THESE SIMPLE IN-

STRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR

COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After

installation, leave these instructions with the Fountain for future reference.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

IMPORTANT

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A

COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS

GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A

METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING

THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF

PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

INSTALLER

STOP!

PLEASE READ THE FOLLOWING

INFORMATION.

• INSTALLATION INSTRUCTIONS FOR THE 4410FR FTN.

WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE

LOCATED ON PAGES 2 - 5.

• INSTALLATION INSTRUCTIONS FOR THE 4410FR FTN.

WITH SANITARYFR1 VALVE ARE LOCATED ON PAGES

6 - 12.

Содержание 4410

Страница 1: ...ICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBAC...

Страница 2: ...emoved for servicing the valve 5 We recommend that the top of the column be flush or slightly above the top height of the concrete pad 6 You should test the unit before you backfill Simply blow on the...

Страница 3: ...VABLE BOTTOM COVER C 1 PVC DRAIN D PRESSURE FITTING 1 1 4 x 3 4 E CONNECTOR 1 1 4 TO 1 1 4 F 1 1 4 DRAIN TUBE G AIR CONTROL LINE H 1 4 WATER LINE J CONNECTOR FOR AIR CONTROL LINE SITE PREPARATION DETA...

Страница 4: ...NSTALLING 97243C SINGLE VALVE CONTROL ASSY 1 Prepare trench for water supply and waste drain lines if required by local codes The hole should be deep enough to accommodate the PVC column and 5 cubic f...

Страница 5: ...7243C 45787C 45788C 45789C 45790C 55960C 75565C 75521C 75596C 56092C 56123C 28091C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 NS NS NS NS NS Drain Gasket...

Страница 6: ...mn Additional porous fill and drain pipe may be required due to local ground conditions Cut the PVC column to fit desired bury depth Set PVC column in excavating pit 2 Lay drain lines and water supply...

Страница 7: ...PAGE 7 4410FR FTN 97733C Rev G 04 04 SUGGESTED SITE PREPARATION DETAIL FOR THE 4410FR FTN WHEN USING THE SANITARYFR1 VALVE FIG 1...

Страница 8: ...SITE PREPARATION DETAIL FOR THE 4410FR FTN WHEN USING THE SANITARYFR1 VALVE 1 1 4 DRAIN TUBE SUPPLIEDWITHFTN AIR GAP ASSY SUPPLIEDWITHVALVE 1 1 2 DRAIN TUBE SUPPLIEDBYINSTALLER Detail A LEGEND A ACCE...

Страница 9: ...ert the 1 4 O D tube Label E into the 1 4 union provided with valve assembly Insert the 1 4 O D water line coming from the fountain into union Trim any excess length Step 4 Insert the 1 4 O D tube Lab...

Страница 10: ...PAGE 10 4410FR FTN 97733C Rev G 04 04 Detail B 13 15 2 14 5 3 11 4 12 5 6 6 5 13 15 10 See Detail B FIG 4 FIG 5 Stream Height Adjustment...

Страница 11: ...older Regulator Nut Poly Tubing 1 4 Cut To Length To Bubbler Poly Tubing 1 8 Cut To Length To Actuator Canister Trap Adaptor 1 1 2 x 1 1 4 Air Gap Assy Fitting 1 2 Union w Strainer Regulator Fitting E...

Страница 12: ...ton to the valve Make sure the air tubing compression nut is hand tight Disconnect air tube from push button Place finger over air outlet Push button to test diaphragm Tighten diaphragm cap screws Rep...

Отзывы: