background image

PAGE 11

4410FR-FTN

97733C (Rev. G - 04/04)

DESCRIPTION

110175443890

45806C

50986C

56082C

56092C

56123C

56185C

56186C

56203C

56235C

61313C

70817C

70828C

75639C

75642C

75652C

75653C

70683C

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

NS

PART NO.

Hex Nut - 3/8-16

Single Valve

Regulator Holder

Regulator Nut

Poly Tubing - 1/4” 

(Cut To Length) - To Bubbler

Poly Tubing - 1/8” 

(Cut To Length) - To Actuator

Canister

Trap - Adaptor 1-1/2 x 1-1/4

Air Gap Assy.

Fitting - 1/2” Union w/Strainer

Regulator

Fitting - Elbow 1/4 Stem x 1/4 Tube

Fitting - Connector 1/4 x 1/4 NPTF

Fitting - Elbow 1/4 x 1/4 NPTF

Fitting - Adaptor 1/4 NPT x 1/2 NPT

U-Bolt

Nylon Strap - 6 ft.

Fitting - Union 1/4

ITEM NO.

PARTS LIST

7

17

16

1

FIG. 8

9

8

FIG. 6

FIG. 7

The Following Items are included with

the SanitaryFR1 Valve

Содержание 4410

Страница 1: ...ICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBAC...

Страница 2: ...emoved for servicing the valve 5 We recommend that the top of the column be flush or slightly above the top height of the concrete pad 6 You should test the unit before you backfill Simply blow on the...

Страница 3: ...VABLE BOTTOM COVER C 1 PVC DRAIN D PRESSURE FITTING 1 1 4 x 3 4 E CONNECTOR 1 1 4 TO 1 1 4 F 1 1 4 DRAIN TUBE G AIR CONTROL LINE H 1 4 WATER LINE J CONNECTOR FOR AIR CONTROL LINE SITE PREPARATION DETA...

Страница 4: ...NSTALLING 97243C SINGLE VALVE CONTROL ASSY 1 Prepare trench for water supply and waste drain lines if required by local codes The hole should be deep enough to accommodate the PVC column and 5 cubic f...

Страница 5: ...7243C 45787C 45788C 45789C 45790C 55960C 75565C 75521C 75596C 56092C 56123C 28091C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 NS NS NS NS NS Drain Gasket...

Страница 6: ...mn Additional porous fill and drain pipe may be required due to local ground conditions Cut the PVC column to fit desired bury depth Set PVC column in excavating pit 2 Lay drain lines and water supply...

Страница 7: ...PAGE 7 4410FR FTN 97733C Rev G 04 04 SUGGESTED SITE PREPARATION DETAIL FOR THE 4410FR FTN WHEN USING THE SANITARYFR1 VALVE FIG 1...

Страница 8: ...SITE PREPARATION DETAIL FOR THE 4410FR FTN WHEN USING THE SANITARYFR1 VALVE 1 1 4 DRAIN TUBE SUPPLIEDWITHFTN AIR GAP ASSY SUPPLIEDWITHVALVE 1 1 2 DRAIN TUBE SUPPLIEDBYINSTALLER Detail A LEGEND A ACCE...

Страница 9: ...ert the 1 4 O D tube Label E into the 1 4 union provided with valve assembly Insert the 1 4 O D water line coming from the fountain into union Trim any excess length Step 4 Insert the 1 4 O D tube Lab...

Страница 10: ...PAGE 10 4410FR FTN 97733C Rev G 04 04 Detail B 13 15 2 14 5 3 11 4 12 5 6 6 5 13 15 10 See Detail B FIG 4 FIG 5 Stream Height Adjustment...

Страница 11: ...older Regulator Nut Poly Tubing 1 4 Cut To Length To Bubbler Poly Tubing 1 8 Cut To Length To Actuator Canister Trap Adaptor 1 1 2 x 1 1 4 Air Gap Assy Fitting 1 2 Union w Strainer Regulator Fitting E...

Страница 12: ...ton to the valve Make sure the air tubing compression nut is hand tight Disconnect air tube from push button Place finger over air outlet Push button to test diaphragm Tighten diaphragm cap screws Rep...

Отзывы: