Page 16
STEP 1I
- Press NEXT and Up simultaneously for 3 seconds.
STEP 2I
– Hardness: Set the amount of hardness in grains of hardness as calcium
car bon ate per gallon using the Down or Up buttons. The default is 20 with value ranges
from 1 to 150 in 1 grain increments. Note: The grains per gallon can be in creased if soluble
iron needs to be reduced. This display will show “–nA–” if “FILTER” is selected in Step 2F
or if ‘AUTO’ is not selected in Step 6S. Press NEXT to go to step 3I. Press REGEN to exit
Installer Dis play Settings.
STEP 3I
– Day Override: When gallon capacity is set to off, Day Override sets the number
of days between re gen er a tions. When gallon capacity is set to AUTO or to a number, Day
Override sets the max i mum number of days between re gen er a tions. If value set to “oFF”
re gen er a tion initiation is based solely on gallons used. If value is set as a number (allowable
range from 1 to 28) a re gen er a tion initiation will be called for on that day even if suffi cient
number of gallons were not used to call for a regeneration. Set Day Override using Down or
Up buttons:
• number of days between regeneration (1 to 28); or
• “oFF”.
See Setting Options Table for more detail on setup. Press NEXT to go to step 4I. Press
REGEN to return to previous step.
STEP 4I
– Next Regeneration Time (hour): Set the hour of day for regeneration using Down
or Up buttons. AM/PM toggles after 12. The default time is 2:00 a.m. This display will show
“REGEN on 0 GAL” if “on 0” is selected in Step 9S or Step 7F. Press NEXT to go to step 5I.
Press REGEN to return to previous step.
STEP 5I
– Next Regeneration Time (minutes): Set the minutes of day for regeneration using
Down or Up buttons. This display will not be shown if “on 0” is selected in Step 9S or Step
7F. Press NEXT to exit Installer Display Settings. Press REGEN to return to previous step.
To initiate a manual regeneration immediately, press and hold the “REGEN” button for
three seconds. The system will begin to re gen er ate im me di ate ly. The control valve may be
stepped through the various re gen er a tion cycles by pressing the “REGEN” button.
General Operation
When the system is operating one of two displays will be
shown. Press ing NEXT will alternate between the dis plays.
One of the displays is always the current time of day. The
second display is one of the fol low ing: days remaining or
gallons remaining. Days remaining is the number of days
left before the system goes through a regeneration cycle.
Ca pac i ty remaining is the number of gallons that will be
treated before the system goes through a regeneration
cycle. The user can scroll between the displays as desired.
If the system has called for a regeneration that will
occur at the preset time of re gen er a tion, the words
REGEN TODAY will appear on the display.
When water is being treated (i.e. water is fl owing through
the system) the word “Soft en ing” fl ashes on the display.
User Display Settings
RETURN TO
NORMAL MODE
OR
REGEN TODAY will be
displayed if a regeneration
is expected “Tonight.”
STEP 1I
STEP 2I
STEP 3I
STEP 4I
STEP 5I
Installer Display Settings