background image

 

 

 

 

 

 
 
 

 

Installation and Operation Manual 

Document Number 013-RD000-000-02-201510 

 

 

 

 

 

 

For Products: JAZ, JAZ-INDY, JAZ-PX 
Document: 013-RD000-000-02-201510 
 

 

 
 

 

 

Содержание Ocean Optics JAZ

Страница 1: ...Installation and Operation Manual Document Number 013 RD000 000 02 201510 For Products JAZ JAZ INDY JAZ PX Document 013 RD000 000 02 201510 ...

Страница 2: ...n from Ocean Optics Inc Trademarks All products and services herein are the trademarks service marks registered trademarks or registered service marks of their respective owners Limit of Liability Every effort has been made to make this manual as complete and as accurate as possible but no warranty or fitness is implied The information provided is on an as is basis Ocean Optics Inc shall have neit...

Страница 3: ...res 2 System Requirements 3 EEPROM Utilization 3 About OceanView Software 3 Sampling System Overview 4 How Sampling Works 4 Interface Options 4 Shipment Components 4 Additional Equipment Available 5 Chapter 2 Installing Jaz 9 Overview 9 Installing the Jaz Unit 10 Connecting Jaz to a Computer via USB 10 Ethernet Connection 10 Chapter 3 Operating Jaz 13 Overview 13 Powering Your Jaz Unit 14 Jaz Menu...

Страница 4: ... JAZ PX Module recommended 33 Chapter 5 Operating the JAZ INDY Module 35 JAZ INDY Module Overview 35 JAZ INDY Module Features 35 JAZ INDY Menu 36 JAZ INDY Menu Defaults 41 Calibrating the JAZ INDY Module 41 Calibrating the Voltage Outputs 42 Calibrating the Voltage Inputs 42 Calibrating the 4 20mA Transmitter 43 Calibrating the 4 20mA Receiver 43 Chapter 6 Maintenance 45 Overview 45 Software Updat...

Страница 5: ...A Calibrating the Wavelength of Jaz 51 Overview 51 About Wavelength Calibration 51 Calibrating the Spectrometer 52 Preparing for Calibration 52 Calibrating the Wavelength of the Spectrometer 52 Saving the New Calibration Coefficients USB Mode 54 Appendix B Specifications 55 Overview 55 Index 59 ...

Страница 6: ...Table of Contents iv 013 RD000 000 02 201510 ...

Страница 7: ...hapter 3 Operating Jaz Provides instructions for using Jaz without OceanView software For information on using Jaz with OceanView see the OceanView manual see Product Related Documentation below Chapter 4 Operating the JAZ PX Module Contains instructions for using the JAZ PX module Includes menus and setup information Chapter 5 Operating the JAZ INDY Module Provides instructions for the JAZ INDY m...

Страница 8: ...Upgrades Occasionally you may find that you need Ocean Optics to make a change or an upgrade to your system To facilitate these changes you must first contact Customer Support and obtain a Return Merchandise Authorization RMA number Please contact Ocean Optics for specific instructions when returning a product Warranty Our 3 Year Warranty covers Ocean Optics miniature fiber optic spectrometers lig...

Страница 9: ...rence when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the...

Страница 10: ...About This Manual viii 013 RD000 000 02 201510 ...

Страница 11: ...lithium ion battery and up to 8 spectrometer modules to make Jaz the first analytical instrument easily adaptable for the field lab or process environment Jaz can also connect to a computer via the USB port When connected through a USB 2 0 or 1 1 the spectrometer draws power from the host computer Jaz like all USB devices can be controlled by our OceanView software Jaz is extremely adaptable It ca...

Страница 12: ...puts and outputs JAZ PX Pulsed xenon light source JAZ UV VIS Deuterium tungsten halogen light source JAZ VIS NIR Tungsten halogen light source JAZ INTLED LED module that allows you to replace the following LED assmblies JAZ L640 640 nm red LED JAZ L590 590 nm yellow LED JAZ L450 470 nm blue LED JAZ L365 365 nm UV LED JAZ LWHITE White LED JAZ NEOFOX Jaz NeoFox Sport oxygen sensing module for measur...

Страница 13: ...nView software application reads these values directly from the spectrometer enabling the ability to hot swap spectrometers between computers without entering the spectrometer coefficients manually on each computer About OceanView Software Although Jaz is unique in that it can perform a number of spectroscopy measurements and display results right on its display screen OceanView spectrometer opera...

Страница 14: ...a as a free standing unit from the battery embedded in the stack The Jaz stack also has both USB and Ethernet port connectors enabling you to connect the spectrometer to a computer via a USB port or to the network via a connection from the Ethernet port to a Power Over Ethernet POE bridge or a switch to the network e g a network hub Your Jaz stack receives power from either connection and both con...

Страница 15: ...ia the USB port Note Please save the Wavelength Calibration Data Sheet for future reference Additional Equipment Available In addition to the Jaz Modules the following software and accessories are available for use with Jaz Visit us at www OceanOptics com for a complete list of products available for all of your spectroscopy needs JAZ MNT DIN3 rail mounting kit JAZ MNT WALL wall mounting kit for m...

Страница 16: ...measurements Spectroradiometric calibration service 350 1000 nm JAZ PACK S carrying case with shoulder strap JAZ CASE 1450 Jaz Pelican case Jaz EL 350 for VIS NIR applications includes the following Jaz Spectrometer Grating 2 350 1000 nm Detector 350 1000 nm INTSMA 25 25mm slit L2 light collection lens Battery module OceanView software Jaz EL 200 for UV VIS applications Jaz Spectrometer Grating 1 ...

Страница 17: ...SX and Linux operating systems JAZ A IRRAD absolute irradiance application Available on an SD card for onboard absolute irradiance measurements Jaz Scripting Language Allows you to write scripts for your Jaz system to perform simple data acquisition processing and exporting of results to an SD card Jaz Application Programming Interface API enables 3rd party development for Jaz NeoFox Sport Availab...

Страница 18: ...1 Introduction 8 013 RD000 000 02 201510 ...

Страница 19: ...ectrometer to a computer The OceanView software installation installs the drivers required for Jaz If you do not install OceanView first the computer will not properly recognize Jaz Follow the prompts in the OceanView installer wizard If you have already connected Jaz to a computer running on a Windows platform prior to installing OceanView consult Jaz Connected to Computer Prior to OceanView Inst...

Страница 20: ...ecognize the new hardware For Mac users this step is not necessary 3 In OceanView use the Device Manager for your Jaz unit to be recognized in the OceanView software Ethernet Connection You can connect Jaz to the network via the Ethernet port on the JAZ E module A ferrite is provided with your JAZ E Ethernet module to be used in the event that you experience interference with any electronic device...

Страница 21: ...00 02 201510 11 2 Open the ferrite 3 Place the ferrite on the Ethernet cable as close to the connector for the computer as possible 4 Loop the Ethernet cable through the ferrite twice 5 Snap the ferrite closed to lock it in place ...

Страница 22: ...cable into the Ethernet connector on the JAZ E module and then to a Power Over Ethernet POE bridge or switch to the network e g an 8 port network hub 7 In OceanView click to Display the Device Manager then click Rescan Your Jaz unit should be recognized in OceanView ...

Страница 23: ...Perform absorbance reflectance and irradiance experiments and read the results on the Jaz display screen View and edit network settings View battery charge Set display backlight intensity Update the flash memory and system information Rotate the display screen 180 degrees Set date and time Control light source modules in the stack The Jaz faceplate providing you with your interface to the modules ...

Страница 24: ...s not supply sufficient power to drive the Jaz stack or your Ethernet connection is not over a POE enabled switch hub The Jaz stack contains a battery module that should allow for several hours of field operation before the unit must be recharged A power save feature dims the screen to 50 intensity then darkens the screen totally after 3 minutes of inactivity Procedure 1 Connect the power supply c...

Страница 25: ...ck if included Jaz menu function available for DPUs manufactured on January 1 2008 include the following Serial Bus Lets you select the specifics related to the serial bus es in your Jaz stack For Jaz stacks that contain a JAZ INDY module the Indy RS232 and Indy RS585 bus choices are available in addition to the DPU RS232 serial bus File System Allows you to manage SD cards in your Jaz stack Spect...

Страница 26: ...3 Operating Jaz 16 013 RD000 000 02 201510 Jaz Main Menu for DPUs dated January 1 2008 ...

Страница 27: ...4 Operating Jaz 013 RD000 000 02 201510 17 Jaz Main Menu for DPUs dated January 1 2008 Continued ...

Страница 28: ...3 Operating Jaz 18 013 RD000 000 02 201510 Jaz Main Menu for DPUs dated after January 1 2008 ...

Страница 29: ...008 Measurement Wizards Jaz features shortcut wizards that are accessible via the Jaz keypad icons on the navigation keys for the following measurements Absorbance Reflection Transmittance Irradiance Press the button on the keypad that corresponds to the icon for the desired measurement or ...

Страница 30: ... 201510 Tools The Tools menu item provides additional functionality for manual setting of acquisition parameters retrieving information about the spectrometer module properties and lamp set up if applicable for DPUs dated January 1 2008 ...

Страница 31: ...4 Operating Jaz 013 RD000 000 02 201510 21 for DPUs after January 1 2008 ...

Страница 32: ...appears if you have the JAZ INDY module installed in your Jaz stack See Chapter 5 Operating the JAZ INDY Module for the JAZ INDY menu and more in depth information on operating the JAZ INDY module Storing Data on an SD Card The JAZ B and JAZ E modules provide slots for up to 2 GB of storage on an SD card The following are procedures to ensure proper data storage on an SD card Note For best results...

Страница 33: ... used in battery power mode the lamp will operate for approximately 3 hours An additional external power supply is avialable through an optional 38 Watt hour jaz battery extender see Additional Equipment Available For JAZ PX module specifications refer to Appendix B Specifications Caution The spectrometer module is especially sensitive to heating so you should be aware of the effects of heating on...

Страница 34: ...h rate Lamp intensity Number of flashes Holdoff time Flash timing controls Forced trigger Timing reset Free Running mode Run Forever mode continuous trigger Flash output enable disable Trigger enable Advanced settings Read write from to the JAZ PX module control registers Power source battery or external wall power In addition the trigger source internal or external can be selected from the Jaz Sy...

Страница 35: ...4 Operating the JAZ PX Module 013 RD000 000 02 201510 25 JAZ PX Menu JAZ PX Menu Tree ...

Страница 36: ...4 Operating the JAZ PX Module 26 013 RD000 000 02 201510 ...

Страница 37: ... Enable Disable Provides a quick way to prevent or allow the lamp to flash Setup Enables you to manually configure the options for the device Parameters Contains the various numeric parameters that can be set for the JAZ PX Flash Rate Sets the flash frequency in microseconds of the internal timing controller ...

Страница 38: ... mode In this mode the timing generator simply flashes the lamp at the rate that is specified by the Flash Rate parameter and ignores trigger events Run Forever When enabled the timing generator will enter Run Forever mode In this mode it will ignore the Number of Flashes parameter setting and continue flashing forever once it has received a trigger event It will re sync to any trigger events that...

Страница 39: ...ings Menu Power Mode Battery Power Getting Started with the JAZ PX Module You can control your JAZ PX module from the Jaz PX menu see JAZ PX Menu or from OceanView spectrometer operating software if you have purchased OceanView and have your Jaz unit attached to a computer see Operating JAZ PX from OceanView For most applications the JAZ PX module can be quickly configured for either Continuous St...

Страница 40: ...tion period Procedure 1 Set the JAZ PX module to turn Strobe Enable on using PX Lamp Enable Strobe The lamp will not begin to strobe until after you have set the internal trigger 2 Set the Jaz DPU s stack trigger using System Tools Triggering Internal Set Rate This selects the DPU s internal timer as the source for the stack s trigger and sets an appropriate flash rate for the JAZ PX lamp The lamp...

Страница 41: ...iming Ideally the Jaz internal trigger should also be used to synchronize the lamp flashes to the integration periods of any spectrometers in the system Additionally the output of the JAZ PX can be quickly enabled or disabled via the Strobe Lamp Enable check box above the graph Getting Started using JAZ PX with OceanView Procedure 1 In OceanView click on to display the Acquisition Controls 2 Selec...

Страница 42: ...PX Module 32 013 RD000 000 02 201510 5 Select the Main Controls tab 6 Change the Trigger Select Source to Internal and set your Trigger Period in µs 7 Scroll down to Strobe Lamp Enable and check the box to turn the lamp on ...

Страница 43: ...nable and check the box to turn the lamp on 4 Adjust the integration time in increments of 10 ms Internal Trigger Period to ensure that the signal does not vary with each acquisition It is also helpful to set the Scans to Average to 1 so that the signal appears stable After stability is set then increase Scans to Average as desired Note It is important to synchronize the lamp s flash rate internal...

Страница 44: ...4 Operating the JAZ PX Module 34 013 RD000 000 02 201510 ...

Страница 45: ...The Jaz Indy Module is installed in the vertical Jaz stack and operates as part of the fully integrated spectrometer system The module has 4 analog I Os software configurable to 5 to 5 volts and 8 digital I Os Data for analog inputs and outputs can be processed in values such as volts or counts The module complies with RoHS CE and FCC Part 15 Class A requirements JAZ INDY Module Features Experimen...

Страница 46: ...5 Operating the JAZ INDY Module 36 013 RD000 000 02 201510 JAZ INDY Menu ...

Страница 47: ...5 Operating the JAZ INDY Module 013 RD000 000 02 201510 37 ...

Страница 48: ...5 Operating the JAZ INDY Module 38 013 RD000 000 02 201510 ...

Страница 49: ...5 Operating the JAZ INDY Module 013 RD000 000 02 201510 39 ...

Страница 50: ...urrent loop using the 4 20mA Tx setting 0 100 Use the Up Down buttons to select the desired value then press to accept your selection NOTE This menu option will display only if an excitation voltage is connected to the 4 20mA current loop transmitter Monitor Inputs Enables you to monitor the status of the Analog V Analog Current and Digital inputs Analog V Select Analog V to monitor the four Analo...

Страница 51: ...Z INDY Menu Defaults When you first power on the Jaz stack the JAZ INDY module defaults to the following settings Setting Default Value GPIO Menu Set Direction 1 8 Input Set Output Values does not appear until one of the 1 bits is changed to Output Analog V Out V Output 5 00 4 20mA Excitation 4 20mA Excitation 10 Volts 4 20mA Tx Control Set Value 0 Calibrating the JAZ INDY Module Your JAZ INDY mod...

Страница 52: ...ossible to 4 5V Record this value to be used later 5 Using the Jaz menu or OceanView software select the voltage output to be calibrated a Select Minimum then change the voltage to 4 5 and set the counts to the value you measured in Step 2 b Select Zero and enter the counts measured in Step 3 c Select Maximum then change the voltage to 4 5 and set the counts to the value you measured in Step 4 6 R...

Страница 53: ...ior to finishing the calibration Calibrating the 4 20mA Transmitter The JAZ INDY module provides a 4 20mA current controller that must be calibrated There are only two setpoints for this controller 4mA and 20mA The controller can be calibrated by passing the current directly through a digital multimeter ensure first that the meter is rated to withstand at least 30mA to prevent damage JAZ INDY prov...

Страница 54: ...5 Operating the JAZ INDY Module 44 013 RD000 000 02 201510 ...

Страница 55: ...optics com or use the Update Center in OceanView Help Check for Updates Jaz Select System Tools Flash Update from the Jaz menu to download Jaz updates Jaz Troubleshooting The following sections contain information on troubleshooting issues you may encounter when using Jaz Jaz Connected to Computer Prior to OceanView Installation Windows Operating Systems If you connected Jaz to a computer prior to...

Страница 56: ... you cannot locate the unknown device 3 Locate the unknown device marked with a large question mark Right click on the Unknown Device listing and select the Uninstall or Remove option 4 Click the OK button to continue A warning box appears confirming the removal of the Unknown Device Click the OK button to confirm the device removal 5 Disconnect Jaz from your computer 6 Locate the section in this ...

Страница 57: ...are There isn t any long term harm to plugging in the device before installing the software Jaz Troubleshooting Tips The following table provides additional information for troubleshooting Jaz issues If these suggested solutions do not solve the problem please contact us for Technical Support Problem Possible Cause s Suggested Solution s Jaz does not initialize correctly Unit was powered on too qu...

Страница 58: ...initiating USB communication Restart Jaz and wait until it displays the menu screen before starting or re scanning devices in OceanView Jaz can get an IP address and can be pinged over Ethernet but won t otherwise communicate The battery is nearly empty causing Jaz to lose the connection Plug Jaz into the wall power receptacle or use the Power over Ethernet capability Replacing an LED Assembly in ...

Страница 59: ...ey try to push the assembly out of the module 4 Completely remove the screws and set them aside for use in the new LED assembly 5 Pull the LED assembly straight out of the module 6 Align the holes of the new LED assembly with the three holes on the LED module and gently push the LED assembly straight in to the module Do not force the LED assembly into the module 7 Re insert the three 2 56 screws i...

Страница 60: ...6 Maintenance 50 013 RD000 000 02 201510 ...

Страница 61: ...ironmental conditions Ocean Optics recommends periodically recalibrating the Jaz spectrometer About Wavelength Calibration You are going to be solving the following equation which shows that the relationship between pixel number and wavelength is a third order polynomial p I C1 p C2 p2 C3 p3 Where the wavelength of pixel p I the wavelength of pixel 0 C1 the first coefficient nm pixel C2 the second...

Страница 62: ...librating the Wavelength of the Spectrometer Procedure Perform the steps below to calibrate the wavelength of the spectrometer 1 Place the spectrometer operating software into Quick View Scope mode and take a spectrum of your light source Adjust the integration time or the A D conversion frequency until there are several peaks on the screen that are not off scale 2 Move the cursor to one of the pe...

Страница 63: ... 0 13 0 19 5 Use the spreadsheet or calculator to calculate the wavelength calibration coefficients In the spreadsheet program find the functions to perform linear regressions If using Quattro Pro look under Tools Advanced Math If using Excel look under Analysis ToolPak 6 Select the true wavelength as the dependent variable Y Select the pixel number pixel number squared and the pixel number cubed ...

Страница 64: ...ll the software The Welcome screen appears 5 Click the Next button The Destination Location screen appears 6 Accept the default installation location or click the Browse button to specify a directory Then click the Next button The Program Manager Group screen appears 7 Click the Next button The Start Installation screen appears 8 Click the Next button to begin the installation Once the installatio...

Страница 65: ...ebook PCs Operating software OceanView for an additional 199 Fiber optic connector SMA 905 to single strand optical fiber Spectrometer Module JAZ S Grating Options 14 different gratings UV through Shortwave NIR Detector 2048 element linear silicon CCD array L2 Collection Lens Wavelength range 200 1100 nm maximum 650 nm Entrance aperture 5 10 25 50 100 or 200 µm wide slits or fiber no slit AgPlus M...

Страница 66: ...liant 10 100 Data Storage Via SD card Battery Memory Module JAZ B Type Rechargable lithium ion Life 8 hours before recharging L450 Blue LED Light Source JAZ L450 Type LS 450 LED VIS NIR Light Source Module JAZ VIS NIR Type Tungsten halogen Bulb life estimated 1100 hours UV VIS Light Source Module JAZ UV VIS Type Deuterium tungsten halogen Pulsed Xenon Lamp Module JAZ PX tested at 200 Hz flash rate...

Страница 67: ...p life Minimum 10 8 flash Number of flashes before intensity is reduced to 50 Lamp behavior is not characterized beyond lamp life Typical 5x10 9 Power Average 2 5W Peak 3W Spectral range 190 1100 nm Industrial Communications Module JAZ INDY Standards RS 232 and RS 435 ...

Страница 68: ...B Specifications 58 013 RD000 000 02 201510 ...

Страница 69: ...ceplate 13 features 2 free running 30 I installation 9 Ethernet connection 10 Jaz 10 USB connection 10 Interface 4 J JAZ INDY menu 22 JAZ INDY module calibrating 41 calibrating 4 20mA transmitter 43 calibrating voltage inputs 42 calibrating voltage outputs 42 default values 41 features 35 menu description 40 menus 36 overview 35 JAZ PX menu 22 JAZ PX module default values 29 features 24 free runni...

Страница 70: ... 4 P packing list 4 power 14 supply 5 product overview 1 product related documentation vi S Sampling System 4 SD card 22 shipment components 4 specifications 55 System Requirements 3 T triggered mode 30 troubleshooting 45 47 Linux systems 47 Mac systems 47 Windows systems 45 U upgrades vi USB 10 cable 5 connection 10 W warranty vi Wavelength Calibration about 51 Data File 5 Data Sheet 5 what s new...

Отзывы: