Table of Contents 

 

About This Manual ......................................................................................................... iii

 

Document Purpose and Intended Audience .............................................................................. iii

 

What’s New in this Document ................................................................................................... iii

 

Document Summary .................................................................................................................. iii

 

Product-Related Documentation ............................................................................................... iii

 

Upgrades ....................................................................................................................... iv

 

 

Chapter 1: Setup ................................................................................ 1 

Overview ....................................................................................................................... 1

 

Models Available ........................................................................................................... 2

 

Unpacking the HL-3 Series Light Source ....................................................................... 2

 

Contents ........................................................................................................................ 2

 

Connecting a Spectrometer to the HL-3 ......................................................................... 3

 

Connecting a Spectrometer to the HL-3-CAL Models When Using a Cosine Corrector ........... 3

 

Connecting a Spectrometer to the HL-3-INT-CAL Models When Using an Integrating Sphere 4

 

 

Chapter 2: HL-3 Specifications ......................................................... 5 

Operating Environment .................................................................................................. 5

 

Specifications ............................................................................................................................ 5

 

 

Appendix A: Calibration Basics ........................................................ 7 

Overview ....................................................................................................................... 7

 

Calibration for Absolute Irradiance: Models HL-3 plus-CAL, HL-3 plus-CAL-EXT, HL-3-CAL 
and HL-3-CAL-EXT ....................................................................................................... 7

 

Calibration for Radiant Flux ....................................................................................................... 7

 

Uncertainty Level Calculation for HL-3 

plus

 Family ........................................................ 8

 

 

Appendix B: HL-3 Use Log ................................................................ 11 

HL-3 Series Use Log ..................................................................................................... 11

 

 

Index ................................................................................................... 13

 

 

 

Содержание Ocean Optics HL-3 plus -CAL-EXT

Страница 1: ...ight Sources Installation and Operation Manual For Products HL 3 CAL HL 3 CAL EXT HL 3 INT CAL HL 3 INT CAL EXT HL 3 plus CAL HL 3 plus CAL EXT HL 3 plus CAL INT and HL 3 plus CAL INT EXT Document 000...

Страница 2: ...from Ocean Optics Inc Trademarks All products and services herein are the trademarks service marks registered trademarks or registered service marks of their respective owners Limit of Liability Ever...

Страница 3: ...ate an unsafe operating environment 2 Dangerous voltages are present in this device There are NO user serviceable parts inside 3 Only allow qualified personnel to service this unit 4 Inspect this unit...

Страница 4: ...Important Safety Notices B 000 10000 190 02 201502...

Страница 5: ...e HL 3 3 Connecting a Spectrometer to the HL 3 CAL Models When Using a Cosine Corrector 3 Connecting a Spectrometer to the HL 3 INT CAL Models When Using an Integrating Sphere4 Chapter 2 HL 3 Specific...

Страница 6: ...Table of Contents ii 000 10000 190 02 201511...

Страница 7: ...r 1 Setup Contains a list of package contents and unpacking instructions Also contains procedures for connecting to a spectrometer Chapter 2 HL 3 Specifications Contains operating environment specific...

Страница 8: ...hanges you must first contact Customer Support and obtain a Return Merchandise Authorization RMA number Please contact an Ocean Optics Application Scientist for specific instructions when returning a...

Страница 9: ...ths expressed in W cm nm and in a radiant flux in W nm for the INT models Since the spectral intensity of the HL 3 Series can be traced to an intensity standard traceable to the National Institute of...

Страница 10: ...ncertainty to 3 and offer a shutter Model Calibrated Wavelength Range Maximum Uncertainty Level Shutter HL 3 plus CAL 350 1050 nm 3 Yes HL 3 plus CAL EXT 350 2400 nm 3 Yes HL 3 plus INT CAL 350 1050 n...

Страница 11: ...when using a cosine corrector 1 Loosen the set screw on the HL 3 s SMA barrel and the CC 3 cosine corrector adapter slot 2 Screw the CC 3 cosine corrector onto the end of the fiber The connection sho...

Страница 12: ...ug the wall mount AC adapter into a standard outlet 4 Turn the lamp on Allow the lamp to warm up for at least 15 minutes before using it 5 Insert the calibration disk that came with your light source...

Страница 13: ...uld be positioned so that objects do not fall on top of the unit Additionally ensure that no liquids are spilled into the enclosure through openings Specifications Specification Value Spectral Range c...

Страница 14: ...2 HL 3 Specifications 6 000 10000 190 02 201511 Specification Value Connector Regular Models INT Models CC 3 cosine corrector Integrating Sphere Shutter Regular Models plus Models No Yes...

Страница 15: ...cedure Clear documentation of the calibration setup and of the calibrated devices used is an indispensable requirement Calibration for Absolute Irradiance Models HL 3 plus CAL HL 3 plus CAL EXT HL 3 C...

Страница 16: ...S Stability S within 50 hours of operation 2 T and F Influence of temperature T and humidity F in the air The temperatures during calibration have a temperature range of 19 C to 25 C The humidity migh...

Страница 17: ...ties and Uncertainty Budgets in at Wavelength Example 400 500 600 800 1000 1200 1600 1800 2000 2400 Standard uncertainty k 1 5 09 3 64 3 01 3 00 3 04 3 04 3 05 3 04 10 86 10 86 Expanded uncertainty k...

Страница 18: ...A Calibration Basics 10 000 10000 190 02 201511...

Страница 19: ...ries Use Log Use Log No Page No ID No Lamp S N Date Calibrated Reference Standard Working Standard Note Do not exceed 50 hours of total ON time without recalibration Date Used Start Time Stop Time Pri...

Страница 20: ...B HL 3 Use Log 12 000 10000 190 02 201511 Date Used Start Time Stop Time Printed Initials Signature Running Total for on Time Comments...

Страница 21: ...ing sphere 4 cosine corrector 3 D document audience iii purpose iii summary iii I integrating sphere 4 L log 11 M models 2 O operating environment 5 P package contents 2 product related documentation...

Страница 22: ...Index 14 000 10000 190 02 201511...

Отзывы: