SL2 (SaunaLogic 2) Control Operation

 

 

Operating Instructions for Heater  
 

Default settings for temperature are preset to 194°F, the bath time is 
set to 60 minutes and 0-minute delay to start to heat.  These settings 
are adjustable (as described below) from 119°F to 194°F. Length of 
sauna can be set from 0 to 60 minutes. The time delay before start 
can be up to 24 hours. Any changes are remembered by the heater 
for your next bath.  Should the heater power be lost then restored, 
the settings will return to their default values. 
 
STARTING SAUNA HEATER IMMEDIATELY 

Press the control POWER 

 icon to turn on the sauna control and 

heater. The room temperature will be displayed on the control.  The 
heater will turn on and begin heating the room to current set points. 
Once the set temperature is reached inside the room, the control will 
turn the heater on and off again as needed to maintain the desired 
temperature.  At the end of the selected time (60 minutes maximum), 
the control will turn itself off and the control display will turn off. 
 
SETTING THE TIME AND TEMPERATURE   
To set the sauna length time, press the 

 icon and then press the 

“"+" or "-" icons to increase or decrease time for desired setting. The 
maximum of time is 60 minutes. 
 

To set the temperature, press the 

 and next "+" or "-" icons to increase or decrease temperature for desired 

setting. The maximum temperature is 194°F (90°C).  
 
Note: Typical sauna bathing set-point temperature is 150°F to 165°F on the control. 
 
PRE-SET DELAYED START 

Press the 

 icon and delay time will appear in the display and will toggle between “dlay” the amount of time 

remaining. The maximum of time is 24 hours. If no delay is desired, press 

 icon to toggle off the function.  

 

Operating Instructions for Lighting 

 

Press 

 icon to cycle through lighting options. Press and hold the 

 

 icon for 3 seconds to turn off the 

lights. Lights will turn off automatically 10 minutes after sauna cycle is completed.  
 

-

 

Color sequence – White – Red – Green – Blue – Yellow – Aqua – Purple – Rotation of Colors – Off 

 
Choose the color of choice and then set lighting brightness. The brightness will be on display for 3 seconds. 
Press the “+” or “-“ icon to increase or decrease the light setting. Setting options are 25, 50, 75, and 100% light 
output. 
 
 
 

 

 

Содержание V3 Series

Страница 1: ...nd HM 66C with SL2 Control and CB 16 1 and Bluetooth Sound System Read Before Installation 2 Precautions Before Use 2 Room Assembly 3 Electrical Heater Assembly 5 Bench Interior Assembly 8 SL2 Control Operations 10 Bluetooth Sound System Operation 11 User Maintenance Instructions 11 HM V3 55C Room HM V3 66C Room ...

Страница 2: ...rface PRECAUTIONS BEFORE USE WARNING Prolonged exposure to elevated temperatures is capable of inducing hyperthermia Hyperthermia occurs when the internal temperature of the body reaches several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia include an increase in the normal temperature of the body dizziness lethargy drowsiness and fainting The effects of the hype...

Страница 3: ...ual in height Refer to Picture 3 o If they are not equal in height or there is an obvious gap between the two panels that means they are not properly attached and you should try again Typical room installation is as follows 1 Place floor base panel on level surface If not even shim the base panel until level 2 Place back right wall panel on floor base panel 3 Place right wall panel on floor base p...

Страница 4: ...t panel and the left back panel Interlock the right front panel and the right back panel 4 Place door panel in room and latch to front panels 5 Place the ceiling panel on the wall panels Make sure trim of the top panel fits completely around the walls Note Make sure the connection wires from the front right wall and back wall panel protrude through the hole of the ceiling panel 6 Connect the wires...

Страница 5: ...8 screws on the lower side of the heater to remove the lower portion of the heater save screws for re installation 10 Install the strain relief clamp as shown about 2 5 from the end of the black rubber insulation Remove the retaining nut for later installation in heater Tighten the two clamp screws securely so that the strain relief does not slide on the cable 11 Insert the cable into the open hol...

Страница 6: ...pt Circuit device is not required by NEC A GFCI may be installed if required by local codes but will nuisance trip during use of the product CAUTION Loose wire connections can cause heat damage to wires terminal blocks and other components and may void the warranty 14 Connect wires from building electrical supply to the lower terminal block labeled L1 L2 and Gnd Building wire is not supplied 15 Co...

Страница 7: ... 8 screws provided The heater guard location is marked on both walls with a label Place the bottom of the heater guard to cover the label on the walls and secure into location 20 Ensure all electrical connections are secure and safe 21 Apply power to the CB box and ensure the control lights up and is active See Controls Section of Operation information ...

Страница 8: ...h systems have three benches Upper Main Bench Upper Return Bench and Lower Main Bench c Place the lower bench along the wall spanning from left wall to right wall d The upper main bench spans from the left wall to right wall e Secure the armrest to the wall with screws f The shorter upper return bench butts up to the main upper bench to the armrest support near front wall See photos below for HM 6...

Страница 9: ...e sure to install at the same level to ensure a well balanced look Hallmark 66C 27 Connect the wires from the left end of the main backrest and connect it to the return backrest and then mount the backrest Note Test lights before mounting the back rest 28 Secure back rests behind the benches Note Holes are predrilled for locations 29 Ensure the ceiling is all the way down and flat Turn the wood ce...

Страница 10: ...trol will turn itself off and the control display will turn off SETTING THE TIME AND TEMPERATURE To set the sauna length time press the icon and then press the or icons to increase or decrease time for desired setting The maximum of time is 60 minutes To set the temperature press the and next or icons to increase or decrease temperature for desired setting The maximum temperature is 194 F 90 C Not...

Страница 11: ...s before using the device in the Sauna IR Room USER MAINTENANCE INSTRUCTIONS Room Instructions for Cleaning Perspiration and dirt may absorb into the wood so periodic cleaning is needed Scrubbing the benches and floorboards with a stiff brush and mild detergent is normally sufficient Light sanding is another option TROUBLESHOOTING Error Codes on controls Sn Means the sensor is not connected to the...

Отзывы: