MODEL VSA-X21 

Auto Detection  
The Auto Detection Active/Inactive button shows the device current setting as well 
as being able to control whether an active source will be detected or not. 

 

Auto Detection Off  

o

 

No action is taken. 

o

 

Factory default is OFF

 

Auto – Triggered or Waiting 

o

 

When the Auto Detection Method control is NOT disabled, the device 
will process the RS232 ON and OFF strings associated with the 
AUTO function whenever a specified event (+5 or Video) occurs. 

o

 

 Waiting signifies that the device is still waiting 
for the specified event to occur. 

o

 

 Triggered signifies that the device has detected 
the specified event. 

 

Off Delay (min)  
The Off Delay (min) control field shows the device current off delay 
value as well as being able to set that value. Factory Default is 3 
minutes. 

 

The control is disabled if the Auto Detection Method is set to Disabled or 
Contact

 

When set to 0 minutes and ‘Auto Detection Method’ is set for ‘+5’ or ‘Video’ 
the RS232 OFF string associated with the AUTO Function will be processed 
immediately. 

 

When set to any value between 1 and 240 minutes, the RS232 OFF string 
associated with the AUTO Function will be processed after the programmed 
delay has elapsed. 

 

Содержание VSA-X21

Страница 1: ...ax 714 641 6698 Address Hall Research 1163 Warner Ave Tustin CA 92780 Web site www hallresearch com E mail info hallresearch com CUSTOMER SUPPORT INFORMATION GUI User s Manual VSA X21 HDMI Audio Extra...

Страница 2: ...our PC the Microsoft website has free downloads available 1 3 Software Installation If an earlier version of this particular software was previously installed UNINSTALL the program first from either t...

Страница 3: ...n 2 2 USB Device Detection The VSA X21 software uses standard Windows drivers which automatically configure the USB port after connection and do not require the installation of any special USB drivers...

Страница 4: ...s an XML extension the file will be interpreted as containing XML data otherwise the file will be interpreted as containing BINARY data Uploading invalid files will result in EDID corruption Export ED...

Страница 5: ...ssigns a descriptive name to be given to the VSA X21 device that is a maximum 8 characters long The user is not allowed to change the device name with multiple devices connected The FACTORY DEFAULT na...

Страница 6: ...M format 2 Chn Indicates HDMI audio received is LPCM format Video Output 5 ON OFF Indicates the state of the 5 vDC signal to the HDMI OUTPUT When the HDMI INPUT 5 vDC is connected the 5 vDC OUTPUT sig...

Страница 7: ...e as well as being able to control the HDMI or ARC state Factory default is HDMI When OFF the HDMI IN audio is mixed and output on the amplifiers speakers and 3 5mm LINE OUT connectors When ON the HDM...

Страница 8: ...video input is active HDBT over Local o The HDBT video input has priority over the Local video input o The Active Input controls disable in this mode o When a video source is detected on the HDBT inp...

Страница 9: ...I KNOB DP Page Sensor Mute o A compatible page sensor connected on the rear terminal strip controls the MUTE function Compatible with Model VSA PGSNS o Whenever a signal is received of sufficient ampl...

Страница 10: ...Delay control is enabled in this mode o The AUTO button in the WEBGUI is visible in this mode Video o The video source must actually send video in order to be detected o When video is received on the...

Страница 11: ...that the device is still waiting for the specified event to occur o Triggered signifies that the device has detected the specified event Off Delay min The Off Delay min control field shows the device...

Страница 12: ...l Port 2 Factory default is NONE for the X21 UI serial port when installed Pass Thru The Pass Thru control shows the device RS232 Pass Thru state as well as being able to control the ON or OFF state F...

Страница 13: ...rate used is whatever the HDBT TX device used The HDBT RS232 stream will NOT be able to control the VSA X21 in this mode X21 UI The X21 UI control setting shows the device current setting as well as b...

Страница 14: ...is ON When OFF no special processing of the HDBT RS232 is done When ON the device will send and receive RS232 commands to from the installed UHBX SW3 WP S for control IR Sender Receiver The IR Sender...

Страница 15: ...ress Factory default is DHCP so the end users compatible DHCP router determines this address DHCP The DHCP control shows the device DHCP status Factory default is ON When OFF the IP address Subnet Mas...

Страница 16: ...ecute the assigned function Type The button type can be set for Momentary or Toggle action Toggle buttons have two RS 232 strings associated with them Momentary buttons have one RS 232 string associat...

Страница 17: ...ommand o Send any valid command to the device IR UI o Send IR code from X21 UI when installed Command when Function is set for Serial Serial UI or Serial HDBT The Command control field is where the us...

Страница 18: ...WP S Communications Tab o UI KNOB DP Communications Tab o VSA PGSNS Communications and Advanced Tabs o X21 UI Communications and Button Tabs By default all buttons are disabled but have no Function or...

Страница 19: ...alid When wrong checksums are detected the invalid checksum byte is highlighted in RED If an action is performed that affects the EDID such as initiating a learn process The checksum field might momen...

Страница 20: ...he HDMI ARC volume will be reduced by the given Ratio Ratio The Ratio control shows the device Ducking Threshold ratio This is the percentage the HDMI ARC volume is reduced when the Ducking Threshold...

Страница 21: ...21 21 MODEL VSA X21...

Страница 22: ...22 User s Manual 22...

Страница 23: ......

Страница 24: ...ved Order toll free in the U S 800 959 6439 FREE technical support Call 714 641 6607 or fax 714 641 6698 Mail order Hall Research 1163 Warner Ave Tustin CA 92780 Web site www hallresearch com E mail i...

Отзывы: