![Hall Research Technologies UHBX-8X Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/hall-research-technologies/uhbx-8x/uhbx-8x_user-manual_3367213005.webp)
UHBX-8X
5
Figure 4 – Hall Research C-HDMI-L high bandwidth
HDMI cable with flip-up locking tab
3.2.2 Extender Serial Data Connection
Figure 5 – RS232 Port
If required, plug a DB9 RS232 cable from any serial control device to the
connector on the box. The RS232 port provides a bi-directional serial
communication with any compatible receiver. This RS232 port operates at a
fixed 19200 baud, 8-bit, no parity, and 1-stop bit. However, it can
communicate with any compatible receiver at any user defined baud rate.
Typically a straight-through male-to-female cable is used to connect to the
extender. Pinout of the RS232 connector on the sender is shown below
DB9-F Pin
Term
Direction
2 TX
Output
3 RX
Input
5 GND
Figure 6 – RS-232 path from UHBX-8X to remote receivers
3.2.3 Extender IP Connection
Figure 5 – IP Port
The RJ45 connector is a 10/100 Base-T Ethernet port. This IP port can be
accessed via Telnet. As shipped, the IP address is configured for DHCP