Response:
OK
<cr>
Command:
CFn <cr>
Stands for IR Carrier Frequency
N
1 2 3 4
IR Freq
36KHz
38KHz
40KHz
56KHz
Factory default is 38 KHz. This command should be used prior to issuing IS9
command if your IR signal is something other than 38 KHz. All infra red
remote controls have a modulation (or carrier) frequency and the vast
majority operate at 38KHz.
Response:
CFn
<cr>
Command:
FD <cr> Stands for Restore Factory Default
This command will restore the unit to factory default condition, use with
care.
Response:
FD <cr>
This indicates that the command completed successfully
Command:
FW <cr> Stands for Query Firmware Version
This command will report the firmware version in the unit. If the firmware is
out of date, you can update the firmware using the USB port on the UHBX-8X.
Please see the Windows GUI Guide for further instructions.
Response:
FWx.x <cr>