Model HR-4P
10
Figure 6 – Configuration Tab
3.11 Serial Commands
•
A serial command can send data to any standard serial device with selectable
baud rate and parity. When sending serial commands, you can also specify a
delay between characters to meet varying requirements.
•
Serial commands can be mixed with other actions for the same input. For
example, you may have a projector configuration string like “PWR_ON”
followed by a
DELAY
followed by an
OUTPUT.
There is no limit to the number
of actions that can be added as long as the 250 character limit is observed.
•
Hexadecimal characters may be entered by using
&H
in front of the 2 digit
Hexadecimal character.
•
Select the desired
Condition
and change
Action
to
Serial
. Commands are
entered in the
Command
text box. When done, the user clicks the
Add
button
to append the command to the existing user string as shown in Figure 7.
Figure 7 – Serial Commands