![Hall Research Technologies HR-4P Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/hall-research-technologies/hr-4p/hr-4p_manual_3329516011.webp)
Programmable Serial Controller
9
3.9 Upload
•
Click the
Upload
button on the left of the Main screen to store the
current configuration strings in a HR-4P unit from the GUI
software. All information stored in the HR-4P will be overwritten.
•
If the configuration string for a specific condition needs to be uploaded, you can
click the
Upload Single
button to the right of the configuration text box as
shown.
3.10 Main Screen Tabs
•
The HR-4P Programmer consists of four different pages in a tabular format.
Each Tab has a specific function suited to a particular task.
Configuration
•
The
Configuration
tab page as seen in Figure 6 is the default tab shown
at software startup.
o
This tab allows the user to build configuration strings.
o
A configuration string can be created to perform one or more specific
actions based on a particular condition.
o
A configuration string can be up to 250 bytes long, and it can be any
combination of serial, time delays, IR codes, outputs, and pulses
actions. Each type of command; Serial, Time Delay, IR, Output and
Pulse each use a few bytes for identifying the desired action. For
example, a Serial Commands uses XX+2 bytes where XX is the
number of bytes the user defines. So… “Hello” uses 4 bytes + 2
bytes for the serial command.
•
Condition
– consists of 5 different real-world discrete inputs
o
CTS, Input 1, Input 2, Input 3, and Input 4.
o
Their state can be high or low.
•
Action
•
Serial
is used to send specific serial characters to a device
•
IR
is used to send an IR code to an IR receiver
•
Delay
is used to add a time delay
•
Output
is used to toggle a specific output on and off
•
Pulse
is used to send timed on/off/on or off/on/off to a output