MiniCAFS 2.1A Operating Manual 
GP/211/05 Issue 2. April 2005

 

 

©Hale Products Europe. Our policy is one of continuous development. We therefore 
reserve the right to amend specifications without notice or obligation. 

 
 

1.  If the unit is installed in the side locker of a fire fighting vehicle, provision must be made 

for access to the engine oil dipstick 

(A)

, compressor oil-fill 

(B)

 and sight glass 

(D)

, all 

located on the rear side of the MiniCAFS. The drive motor is air-cooled, and cooling air 
must be allowed to flow unhindered into and out of the unit. Avoid any enclosing cladding 
at a distance of approx. 300mm around the engine cooling air intake. Compressor oil filter 
is item 

(C)

 
2.  The cooling line 

(L)

 from the heat exchanger should return to the top of the vehicle water 

tank using 

φ

 13 min. diameter flexible hose. There must be no kinks or obstructions in this 

line. 

 
3.  The preferred method of supplying foam agent is from an on board foam tank. This 

MUST

 

be mounted to give a head of foam agent to the FoamLogix pump. The Low-level switch 
(Supplied) 

must

 be installed so that the circuit becomes 

closed

 when the foam tank is 

empty. Connect the low-level switch connection on the foam tank to the Interlock wiring 
harness 

(M)

 on the MiniCAFS, using the extension harness provided.  

 

Note: 

the low foam level switch must be installed in the tank in the correct orientation. 

The switch device has a raised marker on the casing where the wires enter the device. 
This marker must be installed at the 12 o clock (top) position for correct functioning. 
The foam tank requires a 23mm hole for secure fitting of the switch device and the 
maximum allowable thickness of tank wall material is 4mm. 
The switch device should be installed at a location in the tank wall that allows for 
activation when there are approximately 3 litres of foam left before running out.   
 

 

 

 

This marker must be 
at 12 o clock (top) 
when the switch 
device is installed 

Connection (M) 
for low foam level 
switch 

(L) Compressor 
cooling return 
line, inside 
panel 

4.  Connect the foam agent supply to the inlet connection on the FoamLogix pump 

(F)

situated on top of the unit. Note the location of the

 

By-pass valve and connection point 

(G) 

and the

 

foam filter 

(E).

 

Note. Connections must be secure and pressure tight if the FoamLogix pump is 
to operate correctly. 

Water supply of 
between 4-10 bar 
connected to here. 

CAFS or foam 
discharges here 

Содержание MC50

Страница 1: ...ment We therefore reserve the right to amend specifications without notice or obligation MiniCAFS 2 1A Operating Instructions Model MC50 with FoamLogix System A Unit of IDEX Corporation HALE PRODUCTS...

Страница 2: ...CTION 5 RECOMMENDED FUEL LUBRICANTS and ANTI FREEZE 5 GENERAL DATA 6 INSTRUMENTS and CONTROLS 7 8 INTRODUCTION 9 10 INSTALLATION 11 13 COMMISSIONING START UP PROCEDURE 14 OPERATING MiniCAFS FROM A VEH...

Страница 3: ...pment We therefore reserve the right to amend specifications without notice or obligation IMPORTANT NOTES Please read this manual before operating this equipment Every care has been taken during the m...

Страница 4: ...tures DO NOT SMOKE while operating the unit Keep ALL UNTRAINED people AWAY from the unit during operation PETROL IS EXTREMELY FLAMMABLE and MUST be HANDLED WITH CARE DO NOT REFUEL until the engine is...

Страница 5: ...r into water courses Dispose of these through authorised waste disposal contractors to licensed waste disposal sites or to the waste reclamation trade If in doubt contact the Local Authority for advic...

Страница 6: ...ressurised Full Flow System Service Oil Fill Capacity 1 7 litres Oil filter Spin On disposable canister Fuel feed Vacuum Pulse Pump Fuel tank capacity 8 5 litres Battery 12v 14A COMPRESSOR Model HSC50...

Страница 7: ...pril 2005 Hale Products Europe Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation INSTRUMENTS and CONTROLS 1 2 9 14 15 Foam...

Страница 8: ...pressure to aid cold starting 6 Air pressure gauge Indicates air injection pressure 7 Wet or Dry foam indicator Indicates wet or dry composition of foam ENGINE CONTROLS 8 High compressor oil temperatu...

Страница 9: ...ng through the unit 2 Air cannot be injected unless foam and water are flowing through the unit This prevents slugging in the discharge line caused by air and water which cannot mix 3 A low level swit...

Страница 10: ...oam proportioning systems are completely engineered factory matched foam proportioning systems that provide reliable consistent foam concentrate injection for Class A foam operations Hale FoamLogix sy...

Страница 11: ...development We therefore reserve the right to amend specifications without notice or obligation INSTALLATION Caution MiniCAFS is shipped without oil in the Compressor or Engine Oil MUST be added befor...

Страница 12: ...es closed when the foam tank is empty Connect the low level switch connection on the foam tank to the Interlock wiring harness M on the MiniCAFS using the extension harness provided Note the low foam...

Страница 13: ...of the vehicle and led away from the unit Caution Pressurised water must be supplied to the unit any time the engine is run and must be circulating before the engine is switched on Caution The exhaust...

Страница 14: ...ve ambient airflow 1 Follow the installation procedure in the previous section 2 Supply the MiniCAFS with water at a pressure of 4 10 BAR 3 Make sure that an adequate foam supply is available i e foam...

Страница 15: ...AFS switch 3 P8 on the instrument section 2 Stop the unit and check compressor oil level top up if necessary 3 Turn the bypass valve on the FoamLogix pump to bypass arrow points to left and provide a...

Страница 16: ...d branch to the CAFS discharge 38 to 45mm diameter layflat hose is suitable for delivering compressed air foam If a single discharge is being used a 25 to 38mm smooth bore nozzle would be suitable If...

Страница 17: ...Foam CAFS selector switch marked with the symbol No 3 Page 7 1 3 Press the red on button and choose desired foam setting Default is 0 5 Foam Press to increase foam Press to decrease foam 1 4 Open CAF...

Страница 18: ...en the compressor is stopped Shutting Down 2 8 Set WET DRY selector switch to the WET foam setting Press in bottom of switch 2 9 Turn off the FoamLogix press RED button 2 10 Run water through the CAFS...

Страница 19: ...A suitable dip tube should be manufactured for the suction line The bypass pipe should be fed back into the foam canister Note The FoamLogix must be re primed each time the foam canister is changed No...

Страница 20: ...ours or every 3 months Check and clean the water supply filter M Page 12 for debris Every 100 hours or every 6 months whichever comes first Change the engine oil and filter B S oil filter P N 4929325...

Страница 21: ...ork for obstructions Unable to produce foam solution FoamLogix not operating Switch on engine ignition Switch on FoamLogix No Foam in tank Refill with foam agent No air injection CAFS switch not on Tu...

Страница 22: ...d Class A Plus Unifoam Co Ltd UniA 1 Non U S Forestry Service Approved 3M Light Water SFFF RECOMMENDED SPARES FOR 2 YEARS OPERATION ITEM PART No QTY DESCRIPTION COMMENTS ENGINE GROUP 1 B S 4929235 4 O...

Отзывы: