Check to make sure the electrical system for the pool, spa or fountain conforms with 

all requirements of the National Electrical Code (NEC) Article 680-22 requirements 

and any applicable local codes or ordinances. A  licensed  or  certified  professional 

electrician must install the electrical system to meet or exceed all NEC requirements 

and local building codes before the VÜ Nicheless LED Light is installed.

       IMPORTANT SAFETY PRECAUTIONS AND WARNINGS

WARNING

Except when the VÜ Nicheless Underwater LED Lights are installed in an area of the pool 

or spa that is not used for swimming and the lens is adequately guarded to keep any person 

from contacting it, the light shall be installed in or on a wall of the pool, with the top of the 

lens opening not less than 4” (102mm) below the normal water level of the pool.

RISK OF ELECTRIC SHOCK OR ELECTROCUTION WHICH CAN LEAD TO 

SERIOUS INJURY OR DEATH.

Before installing the VÜ Nicheless LED Light read and follow all safety precautions, warning notices and 

instructions which are included in this Installation and Operation Guide. Failure to follow safety precautions, 

warnings and instructions can result in severe injury or death, and damage to the VÜ Nicheless LED Light.

Read Important Safety Precautions and Instructions. Before beginning any electrical wiring, 

be sure to read and carefully follow ALL Safety Instructions. Installation of the 

 

Nicheless 

Light 

should be performed by a qualified professional electrician or pool serviceman.

WARNING

The ColorSplash

®

 VÜ RGB, ColorSplash

®

 VÜ RGB-W  and PureWhite

®

 VÜ Nicheless Underwater 

LED Lights are only availavle for 12 VAC power. For supply connection, use only an isolating low 

voltage power supply with ungrounded output, evaluated and listed by a NRTL for swimming pool use.

RISK OF ELECTRIC SHOCK OR ELECTROCUTION WHICH CAN LEAD TO 

SERIOUS INJURY OR DEATH.

WARNING

INSTALLATION OF THE VÜ NICHELESS LED LIGHT

Use the chart below to determine the appropriate minimum required pipe length for your 

installation. It is recommended to use 1.5" pipe so that lights can easily be upgraded to a 

higher wattage model in the future.

RGB / RGBW / WHITE

WATTS

MINIMUM LENGTH 

FOR 1.5" PIPE 

LPL-R1C-12-XX

8 Watts

3"

LPL-R1CW-12-XX

8 Watts

3"

LPL-R1CW-12-XX

20 Watts

9"

LPL-R1W-12-XX

8 Watts

3"

All products listed above are available in 30, 50, 100 and 150 feet cord lengths. 

NOTE

:

 

The VÜ Nicheless LED Lights are servicable - do not attempt to remove the enclosure of 

cord from the conduit while submerged. No separate ground or bonding wite is required for the 

VÜ Nicheless LED Lights. These lights are low voltage and do not have any exposed metal.

FOR YOUR SAFETY

 - This product must be installed and serviced by a licensed or certified electrician or a qualified 

pool serviceman in accordance with the National Electrical Code (NEC). Before installing this product, read and follow 

all warning notices and instructions accompanying this product. Failure to follow warning notices and instructions may 

result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty. Always 

disconnect the power to the light at the circuit breaker before installing or servicing the light. Failure to do so could result 

in death or serious injury  due to electrical shock. Before installing any underwater light fixtures or lamps read and follow 

all safety precautions, warning notices and instructions which are included in this Installation and Operation Guide. Failure 

to follow safety precautions, warnings and instructions can result in severe injury or death, and damage to the lights.

RISK OF ELECTRIC SHOCK OR ELECTROCUTION.

WARNING

PREPARING THE LIGHT FIXTURE FOR INSTALLATION

NOTE:

 

A licensed electrician must complete the below preparatory steps prior to the 

light fixture being installed (see figure 1).

1.  The junction box or the low-voltage transformer must be located at least eight (8) inches (measured from 

the inside of the bottom of the junction box or transformer) above the MAXIMUM water level, OR at least 

four (4) inches above the ground level or pool deck, whichever is greater.  The junction box or transformer 

must also be installed at least forty-eight (48) inches (4 ft.) from the edge of the pool. (see figure 1).

2.  A standard 1.5" plastic wall / return fitting (not included) must be installed so that the top edge of the VÜ 

Nicheless LED Lights lens is at least four (4) inches (10.2 cm) below the surface of the pool water. 

NOTE: 

Always verify the pool’s electrical system meets all local city and state applicable requirements.

Verify the pool meets the requirements of the current National Electrical Code (NEC) / Canadian Electrical 

Code (CEC) in Canada), and all local codes and ordinances. A licensed or certified electrician must install 

the electrical system to meet or exceed those requirements prior to installing the VÜ Nicheless LED 

Lights. Examples of the  NEC code requirements  pool electrical systems must meet are outlined below.

Содержание J&J Electronics ColorSplash VU LPL-R1C-12...

Страница 1: ...LIABLE FOR ANY OTHER COSTS OR DAMAGES INCLUDING LOST PROFITS OR REVENUES LABOR CHARGES OR FOR ANY INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES J J reserves the right to change the warranty and or warr...

Страница 2: ...llation and or operation will void the warranty Always disconnect the power to the light at the circuit breaker before installing or servicing the light Failure to do so could result in death or serio...

Страница 3: ...LED Lights are servicable do not attempt to remove the enclosure of cord from the conduit while submerged No separate ground or bonding wite is required for the V Nicheless LED Lights These lights are...

Страница 4: ...f theV Nicheless Lights INSTALLING THE V NICHELESS LIGHT FIXTURE See chart on page 4 for min length requirements 1 minimum rigid conduit No 90 degree elbows 4 Min from water level to top of lens 1 5 P...

Страница 5: ...ated and listed by a Nationally RecognizedTesting Laboratory NRTL for swimming pool use RISK OF ELECTRIC SHOCK OR ELECTROCUTION WARNING WIRING TO A SWITCH If required by transformer manufacturer s ins...

Страница 6: ...is is normal during the cycling process During this period the pool spa will be dark and precautions should be taken to avoid any unforeseen accidents Failure to observe this warning may result in ser...

Страница 7: ...in serious injury or death The V Nicheless LED Lights are only available for 12VAC power For supply connection use only an isolating low voltage power supply with ungrounded output evaluated and liste...

Страница 8: ...L RECURSO EXCLUSIVO DEL COMPRADOR EN LUGAR DE OTRAS GARANT AS EXPRESAS O IMPL CITAS INCLUYENDOTODAS LAS GARANT AS DE COMERCIABILIDAD PARA UN FIN PARTICULAR YTODAS LAS GARANT AS DERIVADAS DE NEGOCIACI...

Страница 9: ...El ctrico Nacional NEC Antes de instalar este producto lea y siga todas las advertencias e instrucciones incluidas El incumplimiento de las advertencias e instrucciones puede resultar en da os a la pr...

Страница 10: ...ctrico de la piscina spa o fuente cumple con todos los requisitos del art culo 680 22 del C digo El ctrico Nacional NEC y los c digos y ordenanzas locales aplicables Un electricista profesional certi...

Страница 11: ...Tubo de 1 5 a trav s de las vigas de uni n y una longitud m nima para cada estilo de luz Vea Espect culos de luz p g 4 Conducto el ctrico r gido de 1 Los codos deben ser abiertos o curvos no de 90 Las...

Страница 12: ...LONGITUD DEL CABLE ADVERTENCIA Los voltajes son deerminados por el nivel de voltaje medido en la barra de bus a la que el transformador y los cables est n conectados NOTA Cada color tiene un consumo...

Страница 13: ...l interruptor de la luz No se requiere ning n controlador o interfaz especial Utiliza una caja de conexiones para conectar y operar m ltiples luces con un solo interruptor OPERAR LAS LUCES SUBACU TICA...

Страница 14: ...l siguiente 4 MAREMOTO 6 CIELOS DEL DESIERTO 5 SUE O PATRIOTA Espect culo Cambios r pidos entre colores al azar Ciclo La luz permanecer en cada color durante 2 segundos antes de cambiar al siguiente 7...

Страница 15: ...fuente de alimentaci n de 120VCA en el transformador Compruebe si hay salida de 12VCA en el transformador Compruebe o reinicie el interruptor diferencial GFCI Aseg rese de no haber usado 120 voltios...

Страница 16: ...29 30 NOTES NOTA NOTES NOTA...