background image

5

6

Figure 1:

 

VÜ Nicheless Light installation with standard 1.5" plastic fitting.

48” min. Check local city and state for other j-box requirements.

12 VAC Class 2 Transformer or Junction Box.

8” minimum to maximum water level.

4” min to top of lens.

1.5” pipe through bond beam and a minimum length

for each style light. (See Light Info Charts, p.4)

Rigid 1” Rigid Electrical Conduit. Sweep 

elbows only, no 90º elbows.

Vertical installations such as bench and walk-out locations 

will use ALL of the same clearance requirements.

MAX POSSIBLE WATER LINE (top of copping)

1.  1.5" pipe must be installed through the bond beam with a minimum length of fourteen (14 inches,  

  followed by a one (1) inch conduit with sweeps. DO NOT use 90 degree elbows. It is highly   

  recommended to use 1.5" pipe through out the entire width of the bond beam. (see Figure 2). 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

2.  Snake the 2-Conductor electrical cord through the conduit outlet of the wall fitting, into the  

  conduit and up to the location of the 12VAC pool transformer. Cut off the cord, after allowing  

  for service and length of run to the transformer. A length of cord with 18" - 24" of excess  

  cord is recommended for the service loop. Pull the fixture snug to the wall fitting. 

NOTE:

 

THESE  STEPS  ARE TO  BE  PERFORMED  ONLY  AFTER  ALL  ELECTRICAL 

SYSTEM REQUIREMENTS ARE MET.

NOTE:

 

When using a 1 1/2" MIP fitting on the back of a SP-1022 or SP-1048 wall fitting, 

the interior dimension of the Spears or Dura brands of MIP are both too small for 

proper installation of the VÜ Nicheless Lights.

INSTALLING THE VÜ NICHELESS LIGHT FIXTURE

See chart on page 4 for min. 

length requirements.

1” minimum rigid conduit No 90° 

degree elbows.

4” Min. from water level to top of lens.

1.5” Pipe.

1.5” Threaded wall fitting.

Figure 2: Standard

 

VÜ Nicheless Light installation with 1.5" pool wall fitting.

3.  Using the included Lens Key, thread the light into the  

  wall fitting until it is snug. 

NOTE TO INSTALLER:

 Please provide the pool owner 

with at least 1 Lens Key upon completion of installation.

Figure 3:

 Lens Key Operation.

Tighten

WIRING OPTIONS FOR CONTROLLING THE VÜ 

NICHLESS LIGHTS

Figure 4:

 

Standard VÜ Nicheless Light installation with 1.5" pool wall fitting.

NOTE:

 Always consider the cable length when calculating the input voltage at the 

transformer. The maximum service between a transformer and all the connected lights shoulf 

not exceed 150 ft in length. This includes the primary run from the Junction Box (J-Box). 

Multiple ColorSplash

®

 VÜ Nicheless Lights may be synchronized by being controlled on 

a single circuit, with a single transformer and switch, up to and not exceeding 400 watts.

12VAC Pool Transformer, see table in Wire 

Gauge and Length section for more details.

12VAC Pool Transformer.

NOTE: 

Service Loop 

not applicable for 

Junction Box Installations.

4” Min. from water level to top of lens. 

4” Min. from water level to 

top of lens. 

Allow 18”-24” slack 

for Service Loop. 

Conduit to 12VAC 

transformer. 

Vertical Installation for steps, Benches and Swimouts.

IMPORTANT: 

All

 

ColorSplash

®

 VÜ Nicheless Lights

 

must be on the same circuit  

or switch, or tied into the same transformer in order to synchronize colors. Use  

only solid wire and bus style terminal connectors.

WARNING

Содержание J&J Electronics ColorSplash VU LPL-R1C-12...

Страница 1: ...LIABLE FOR ANY OTHER COSTS OR DAMAGES INCLUDING LOST PROFITS OR REVENUES LABOR CHARGES OR FOR ANY INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES J J reserves the right to change the warranty and or warr...

Страница 2: ...llation and or operation will void the warranty Always disconnect the power to the light at the circuit breaker before installing or servicing the light Failure to do so could result in death or serio...

Страница 3: ...LED Lights are servicable do not attempt to remove the enclosure of cord from the conduit while submerged No separate ground or bonding wite is required for the V Nicheless LED Lights These lights are...

Страница 4: ...f theV Nicheless Lights INSTALLING THE V NICHELESS LIGHT FIXTURE See chart on page 4 for min length requirements 1 minimum rigid conduit No 90 degree elbows 4 Min from water level to top of lens 1 5 P...

Страница 5: ...ated and listed by a Nationally RecognizedTesting Laboratory NRTL for swimming pool use RISK OF ELECTRIC SHOCK OR ELECTROCUTION WARNING WIRING TO A SWITCH If required by transformer manufacturer s ins...

Страница 6: ...is is normal during the cycling process During this period the pool spa will be dark and precautions should be taken to avoid any unforeseen accidents Failure to observe this warning may result in ser...

Страница 7: ...in serious injury or death The V Nicheless LED Lights are only available for 12VAC power For supply connection use only an isolating low voltage power supply with ungrounded output evaluated and liste...

Страница 8: ...L RECURSO EXCLUSIVO DEL COMPRADOR EN LUGAR DE OTRAS GARANT AS EXPRESAS O IMPL CITAS INCLUYENDOTODAS LAS GARANT AS DE COMERCIABILIDAD PARA UN FIN PARTICULAR YTODAS LAS GARANT AS DERIVADAS DE NEGOCIACI...

Страница 9: ...El ctrico Nacional NEC Antes de instalar este producto lea y siga todas las advertencias e instrucciones incluidas El incumplimiento de las advertencias e instrucciones puede resultar en da os a la pr...

Страница 10: ...ctrico de la piscina spa o fuente cumple con todos los requisitos del art culo 680 22 del C digo El ctrico Nacional NEC y los c digos y ordenanzas locales aplicables Un electricista profesional certi...

Страница 11: ...Tubo de 1 5 a trav s de las vigas de uni n y una longitud m nima para cada estilo de luz Vea Espect culos de luz p g 4 Conducto el ctrico r gido de 1 Los codos deben ser abiertos o curvos no de 90 Las...

Страница 12: ...LONGITUD DEL CABLE ADVERTENCIA Los voltajes son deerminados por el nivel de voltaje medido en la barra de bus a la que el transformador y los cables est n conectados NOTA Cada color tiene un consumo...

Страница 13: ...l interruptor de la luz No se requiere ning n controlador o interfaz especial Utiliza una caja de conexiones para conectar y operar m ltiples luces con un solo interruptor OPERAR LAS LUCES SUBACU TICA...

Страница 14: ...l siguiente 4 MAREMOTO 6 CIELOS DEL DESIERTO 5 SUE O PATRIOTA Espect culo Cambios r pidos entre colores al azar Ciclo La luz permanecer en cada color durante 2 segundos antes de cambiar al siguiente 7...

Страница 15: ...fuente de alimentaci n de 120VCA en el transformador Compruebe si hay salida de 12VCA en el transformador Compruebe o reinicie el interruptor diferencial GFCI Aseg rese de no haber usado 120 voltios...

Страница 16: ...29 30 NOTES NOTA NOTES NOTA...

Отзывы: