10. Service messages
Service-Code
Description
Remedy
1.4.6.3.
Suction motor over current or short circuit
Short circuit in the suction motor or in it´s wiring
1.5.4.1.
Malfunction water valve
Water valve over current, interruption in the wiring or short
circuit to battery plus
1.7.4.1.
Chemical dosing agent problems
Chemcal dosing agent over current, interruption in the wiring
3.1.1.2.
Fleetrekorder communication interruption
Check wiring between machine control unit and Fleetrekorder
3.1.1.d.
Battery charger communication to machine
control unit interrupted
Check wiring between -G10.X7 and -A01.X4
3.2.6.5.
Backup battery weak
Replace backup battery; Type CR2032
3.2.6.6.
Backup battery empty
Replace backup battery; Type CR2032
Содержание Scrubmaster B 120 R
Страница 20: ...Sheet 20 2 2 1 Switching off vacuuming dirt water tank full P T S...
Страница 30: ...Sheet 30 3 Technical data...
Страница 31: ...Sheet 31 3 Technical data...
Страница 32: ...Sheet 32 3 Technical data...
Страница 33: ...Sheet 33 3 Technical data...
Страница 34: ...Sheet 34 3 Technical data...
Страница 38: ...Sheet 38 4 2 Hako system maintenance I...
Страница 53: ...6 Machine settings 6 1 6 Charging characteristics of the integrated charger Sheet 53...
Страница 60: ...Sheet 60 7 Mechanical components 7 1 Squeegee Fig 7 2a Fig 7 2b...
Страница 62: ...Sheet 62 7 Mechanical components Height adjustment 7 1 Squeegee Figure 7 4...
Страница 84: ...Sheet 84 10 1 Service alarm clock 3 3 1 1 The service alarm clock is set via the Hako diagnostics system...
Страница 85: ...Sheet 85 11 Battery charger 11 1 Operating manual...
Страница 86: ...Sheet 86 11 Battery charger 11 1 Operating manual...
Страница 87: ...Sheet 87 11 Battery charger 11 1 Operating manual...
Страница 88: ...Sheet 88 11 Battery charger 11 1 Operating manual...
Страница 90: ...11 Battery charger 11 3 Charge data table Sheet 90...
Страница 97: ...Sheet 97 14 Notes...
Страница 98: ...Sheet 98 14 Notes...
Страница 99: ...Sheet 99 14 Notes...