Haklift Oy
Asessorinkatu 3-7
20780 Kaarina, Finland
Tel. +358 2 511 5511
www.haklift.com
Lifting Solutions Group
Axel Johnson International
2.2. Checklist of electrical and safety function
Item Content inspection and safety requirement
Result Comment
1
Is every terminal protected by isolation plate?
YES
2
Does technician follow the procedure number to wire?
YES
3
Are the diameter of grounding wire and each circuit according with safety
requirement of designed electrical circuit?
YES
4
Is fuse according with safety requirement of designed electrical circuit?
YES
5
Are the screws on electric box fixed tightly?
YES
6
Is the electric box equipped with a ventilator (e.g. fan)?
YES
7
Does the design of electric box conform to IP requirement?
YES
8
Is all the function of every control switch and component described specifically
on this operation manual?
YES
9
Are input voltage, frequency, and phase marked correctly?
YES
10
Is the machine earthed?
YES
11
Is there an independent earth copper plate equipped inside electric box?
YES
12
Is every function of control device regular?
YES
13
Is the emergency stop device functional?
YES
14
Is the rotary direction of motor or transmission correct?
YES
15
Is the cover functional (fixed or movable)?
YES
16
Is the machine set stable?
YES
17
Have all the acute angle and fur been ground?
YES
18
Has the machine a CE mark?
YES
19
Has the machine a nameplate?
YES