5-88
14. TOSHIBA MACHINE PLC
14. TOSHIBA MACHINE PLC
Available PLCs
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series is as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Select PLC Type
PLC
Unit/Port
Connection
TC200
TC200
Port on the CPU unit
RS-232C [Wiring Diagram 1]
TCCMW
TCCMO
TCmini
−
Item
Setting on PLC
V7 Comm. Parameter Setting
Baud rate
9600 bps
9600 bps
Port
1
1
Memory
TYPE
Remarks
D
(register 1)
0
B
(register 2)
1
X
(input relay)
2
XW as word device
Y
(output relay)
5
YW as word device
R
(temporary storage)
6
RW as word device
G
(extension temporary storage 1)
7
GW as word device
H
(extension temporary storage 2)
8
HW as word device
L
(latch relay)
9
LW as word device
S
(shift register)
10
SW as word device
E
(edge relay)
11
EW as word device
P
(timer counter current value)
12
V
(timer counter set value)
13
T
(timer)
14
TW as word device
C
(counter)
15
CW as word device
A
(special auxiliary relay)
16
AW as word device
Содержание Monitouch V7
Страница 1: ...V7...
Страница 3: ......
Страница 17: ......
Страница 57: ......
Страница 95: ...2 38 3 Errors Displayed on the V7 Series Please use this page freely...
Страница 97: ......
Страница 150: ...1 Ethernet 2 FL net OPCN 2 3 MELSECNET 10 4 CC Link 5 OPCN 1 6 T LINK 7 PROFIBUS DP Network Communications...
Страница 151: ......
Страница 207: ......
Страница 343: ...5 136 29 Automationdirect PLC Please use this page freely...