100L, 120L, 120LH TROUBLE SHOOTING
A. If you plug power cable but Air Pump do not turn-on:
1. Please open the Pump housing (Please see operation manual page 5 Process 1~5) and check the
parts 8 (Security Stopper).
If the Security Stopper the Triangle symbol like (picture 1) is wrong. That is because the shipment or
people who movement the air pump in wrong way. Please use the screw driver or coin turn the
Triangle symbol like (picture 2).
2. Put the Air pump cover back then plug in the power cable turn on again.
B. If your pump running after several days or several weeks then stop:
Please open the air pump housing (Please see operation manual page 5 Process 1~5) and cheek the
parts 13 (Magnet)
If you see the Magnet position already shift (please see the picture 3) not in the middle of
Electromagnet (Please see operation manual page 5 Part 7) then please use screw driver to move the
Magnet back to the normal position (Please see the picture 4).