11
12
7. PARAMETER SETTING
Value
℉( )/℃( )
30 - 300℃ (54 - 540℉)
OFF( )/ON( )
OFF( )/ON( )
High power( )/Normal power( )
Open ( ) / Partial ( ) / Restricted ( )
: ○* / : ×*
: ○* / : ×*
: ○* / : ×*
0 - 60 sec.
3, 5, 8 m
(TX1) / (TX2)
Initial value
℃
300℃
ON ( )
ON ( )
High power( )
Open( )
ー
3 sec.
3 m
Parameter name
Temperature display
Low temperature error setting
Buzzer setting
(S-E sound , C-E sound)
Buzzer setting
(set temperature achieving alert)
Power-mode setting
Password lock setting
Changing the set temperature
Changing the preset number
Changing the offset value
Password
Ready signal delay time
Cable length setting
Parameter number
Select three letters
Entering the tip offset value
Example
:
If the measured temperature is 410℃ and set temperature is 400℃, the difference
is -10℃. (need to decrease by 10℃) So, enter the figure which 10 is deducted from
present offset value.
1. Press and hold the button for at least one second.
The hundreds digit will begin to flash, the unit will move to the offset mode.
2. Enter the offset value (-10) which is the difference between tip temperature and set temperature.
The allowable ranges for offset values are from -50 to +50℃ (In ℉ mode, from -90 to +90℉)
If you enter a value outside the offset value range, the display returns to the hundreds digit,
and you have to enter a correct value.
3. Entering from hundreds to units digit
Press the button or to set the desired figure.
The hundreds digit can display 0 (for positive value) or minus sign (for negative value)
(Same values vcan be selected in ℉ mode.)
Values from 0 to 5 can be selected when entering the ten digit.
(In ℉ mode, values from 0 to 9 can be selected.)
Values from 0 to 9 can be selected when entering the units digit.
(Same values can be selected in ℉ mode.)
After entering the units digit, press the button to save the figure to the sytem memory
and begin heater control with the new offset value.
Press and hold the button
for at least one second.
Press the button once.
Prees the button once.
Prees the button once.
Prees the button once.
●
03
:
Low temperature error
・
When the temperature drops below a set limit, an error is displayed and a buzzer sounds.
When the temperature returns within the allowable range, a buzzer stops.
Low temperature setting range
:
For Celsius 30 - 300℃ / For Fahrenheit 54 - 540℉
Example
:
When the set temperature is 350℃ and low temperature error setting is 100℃,
a buzzer sounds when the temperature drops to 250℃.
The hundreds digit begins to flash when entering the low temperature setting mode. Use the method
for setting the temperature to enter and set the low temperature setting. If you enter a value outside
the low temperature setting range, the display returns to the hundreds digit, and you have to enter
a correct value.
●
01
:
Temperature display
When the display changes to or , the station enters the mode for changing the temperature display.
:
℃ (Celsius)
:
℉ (Fahrenheit)
Turn on the power switch while pressing the and button, the station will enter the parameter
setting mode. (When the display shows flashing, the station is in the parameter setting mode.)
Use the or button to select parameter number and press the button to move to next step.
Use the or button to select and press the button to set the desired figure.
After the necessary parameters are set, press and hold the button for at least one second.
The display changes to (Yes) and press the button to exit the parameter entry mode.
If you press the or button to select (No), you will return to previous screen.
If the power switched off or lost during the exucution of this procedure, no data will be entered.
CAUTION
* ○:
Password not required
×:
Password required